Current control schemes for three-phase fourwire shunt active power filters: a comparative study

Fuente: Redalyc
Saved in:
Bibliographic Details
Main Author: Johann Petit Suárez
Format: Artículo científico
Language:en
Published: Universidad de Antioquia 2010
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1876482433700855808
author Johann Petit Suárez
author_facet Johann Petit Suárez
contents Current control schemes for three-phase fourwire shunt active power filters: a comparative study Johann Petit Suárez Hortensia Amarís Guillermo Robles Ingeniería VSI Control power quality harmonic compensation active power filter (APF) This paper discusses the performance of different current control schemes used in three- phase four-wire shunt active power filters (APF). The control schemes are based on: Delta Modulation (DM), dead-beat control and PI regulator. The feasibility of the three control schemes have been tested with different waveform and the results are compared through the instantaneous error and the root mean square error between the current of the active power filter and its reference. Finally, the best controller is applied in an experimental setup designed for mitigating harmonics generated by a nonlinear load. 2010 artículo científico 0120-6230 https://www.redalyc.org/articulo.oa?id=43016342018 en http://www.redalyc.org/revista.oa?id=430 Revista Facultad de Ingeniería Universidad de Antioquia application/pdf Universidad de Antioquia Revista Facultad de Ingeniería Universidad de Antioquia (Colombia) Num.52
format Artículo científico
id redalyc_43016342018
institution Redalyc
language en
publishDate 2010
publisher Universidad de Antioquia
spellingShingle Current control schemes for three-phase fourwire shunt active power filters: a comparative study
Johann Petit Suárez
Ingeniería
VSI Control
power quality
harmonic compensation
active power filter (APF)
Current control schemes for three-phase fourwire shunt active power filters: a comparative study Johann Petit Suárez Hortensia Amarís Guillermo Robles Ingeniería VSI Control power quality harmonic compensation active power filter (APF) This paper discusses the performance of different current control schemes used in three- phase four-wire shunt active power filters (APF). The control schemes are based on: Delta Modulation (DM), dead-beat control and PI regulator. The feasibility of the three control schemes have been tested with different waveform and the results are compared through the instantaneous error and the root mean square error between the current of the active power filter and its reference. Finally, the best controller is applied in an experimental setup designed for mitigating harmonics generated by a nonlinear load. 2010 artículo científico 0120-6230 https://www.redalyc.org/articulo.oa?id=43016342018 en http://www.redalyc.org/revista.oa?id=430 Revista Facultad de Ingeniería Universidad de Antioquia application/pdf Universidad de Antioquia Revista Facultad de Ingeniería Universidad de Antioquia (Colombia) Num.52
title Current control schemes for three-phase fourwire shunt active power filters: a comparative study
topic Ingeniería
VSI Control
power quality
harmonic compensation
active power filter (APF)
url https://www.redalyc.org/articulo.oa?id=43016342018