Current control schemes for three-phase fourwire shunt active power filters: a comparative study
Fuente:
Redalyc
Saved in:
| Main Author: | |
|---|---|
| Format: | Artículo científico |
| Language: | en |
| Published: |
Universidad de Antioquia
2010
|
| Subjects: | |
| Online Access: | |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1876482433700855808 |
|---|---|
| author | Johann Petit Suárez |
| author_facet | Johann Petit Suárez |
| contents | Current control schemes for three-phase fourwire shunt active power filters: a comparative study Johann Petit Suárez Hortensia Amarís Guillermo Robles Ingeniería VSI Control power quality harmonic compensation active power filter (APF) This paper discusses the performance of different current control schemes used in three- phase four-wire shunt active power filters (APF). The control schemes are based on: Delta Modulation (DM), dead-beat control and PI regulator. The feasibility of the three control schemes have been tested with different waveform and the results are compared through the instantaneous error and the root mean square error between the current of the active power filter and its reference. Finally, the best controller is applied in an experimental setup designed for mitigating harmonics generated by a nonlinear load. 2010 artículo científico 0120-6230 https://www.redalyc.org/articulo.oa?id=43016342018 en http://www.redalyc.org/revista.oa?id=430 Revista Facultad de Ingeniería Universidad de Antioquia application/pdf Universidad de Antioquia Revista Facultad de Ingeniería Universidad de Antioquia (Colombia) Num.52 |
| format | Artículo científico |
| id | redalyc_43016342018 |
| institution | Redalyc |
| language | en |
| publishDate | 2010 |
| publisher | Universidad de Antioquia |
| spellingShingle | Current control schemes for three-phase fourwire shunt active power filters: a comparative study Johann Petit Suárez Ingeniería VSI Control power quality harmonic compensation active power filter (APF) Current control schemes for three-phase fourwire shunt active power filters: a comparative study Johann Petit Suárez Hortensia Amarís Guillermo Robles Ingeniería VSI Control power quality harmonic compensation active power filter (APF) This paper discusses the performance of different current control schemes used in three- phase four-wire shunt active power filters (APF). The control schemes are based on: Delta Modulation (DM), dead-beat control and PI regulator. The feasibility of the three control schemes have been tested with different waveform and the results are compared through the instantaneous error and the root mean square error between the current of the active power filter and its reference. Finally, the best controller is applied in an experimental setup designed for mitigating harmonics generated by a nonlinear load. 2010 artículo científico 0120-6230 https://www.redalyc.org/articulo.oa?id=43016342018 en http://www.redalyc.org/revista.oa?id=430 Revista Facultad de Ingeniería Universidad de Antioquia application/pdf Universidad de Antioquia Revista Facultad de Ingeniería Universidad de Antioquia (Colombia) Num.52 |
| title | Current control schemes for three-phase fourwire shunt active power filters: a comparative study |
| topic | Ingeniería VSI Control power quality harmonic compensation active power filter (APF) |
| url | https://www.redalyc.org/articulo.oa?id=43016342018 |