Comparing dam movements obtained with Terrestrial Laser Scanner (TLS) data against direct pendulums records

Fuente: Redalyc
Saved in:
Bibliographic Details
Main Author: Luis Ramos-Alcázar
Format: Artículo científico
Language:en
Published: Universidad de Antioquia 2015
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1876447841013989376
author Luis Ramos-Alcázar
author_facet Luis Ramos-Alcázar
contents Comparing dam movements obtained with Terrestrial Laser Scanner (TLS) data against direct pendulums records Luis Ramos-Alcázar Miguel Marchamalo-Sacristán Rubén Martínez-Marín Ingeniería TLS area pendulums precision based analysis The results of the study carried out in a gravity-arch dam to measure its seasonalmovements with TLS are presented. These values are compared with radial movementsof the dam crest recorded by direct pendulums. The results show differences, only fewmillimeters, being the best result one millimeter discrepancy. The factors that have beenconsidered are the precision and accuracy of the equipment, distance and angle of incidenceof the laser beam, the density of the point cloud and the size of the triangles of the meshes.Considerations about density of point clouds and size of triangular meshes are made. In thisstudy, a 7 cm distance between points and a 20 cm mesh size have given good results. Finally,a methodology is proposed to compare by reference to one of the meshes. 2015 artículo científico 0120-6230 https://www.redalyc.org/articulo.oa?id=43042289012 en http://www.redalyc.org/revista.oa?id=430 Revista Facultad de Ingeniería Universidad de Antioquia application/pdf Universidad de Antioquia Revista Facultad de Ingeniería Universidad de Antioquia (Colombia) Num.76
format Artículo científico
id redalyc_43042289012
institution Redalyc
language en
publishDate 2015
publisher Universidad de Antioquia
spellingShingle Comparing dam movements obtained with Terrestrial Laser Scanner (TLS) data against direct pendulums records
Luis Ramos-Alcázar
Ingeniería
TLS
area
pendulums
precision
based analysis
Comparing dam movements obtained with Terrestrial Laser Scanner (TLS) data against direct pendulums records Luis Ramos-Alcázar Miguel Marchamalo-Sacristán Rubén Martínez-Marín Ingeniería TLS area pendulums precision based analysis The results of the study carried out in a gravity-arch dam to measure its seasonalmovements with TLS are presented. These values are compared with radial movementsof the dam crest recorded by direct pendulums. The results show differences, only fewmillimeters, being the best result one millimeter discrepancy. The factors that have beenconsidered are the precision and accuracy of the equipment, distance and angle of incidenceof the laser beam, the density of the point cloud and the size of the triangles of the meshes.Considerations about density of point clouds and size of triangular meshes are made. In thisstudy, a 7 cm distance between points and a 20 cm mesh size have given good results. Finally,a methodology is proposed to compare by reference to one of the meshes. 2015 artículo científico 0120-6230 https://www.redalyc.org/articulo.oa?id=43042289012 en http://www.redalyc.org/revista.oa?id=430 Revista Facultad de Ingeniería Universidad de Antioquia application/pdf Universidad de Antioquia Revista Facultad de Ingeniería Universidad de Antioquia (Colombia) Num.76
title Comparing dam movements obtained with Terrestrial Laser Scanner (TLS) data against direct pendulums records
topic Ingeniería
TLS
area
pendulums
precision
based analysis
url https://www.redalyc.org/articulo.oa?id=43042289012