Thermal behavior of alternative materials used as roof and efficiency of the reflective painting on the external face

Fuente: Redalyc
Enregistré dans:
Détails bibliographiques
Auteur principal: Eduardo Alves de Almeida
Format: Artículo científico
Langue:en
Publié: Universidad de Antioquia 2017
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1876482553127370752
author Eduardo Alves de Almeida
author_facet Eduardo Alves de Almeida
contents Thermal behavior of alternative materials used as roof and efficiency of the reflective painting on the external face Eduardo Alves de Almeida Roberta Passini Ingeniería bio construction sustainability Thermal efficiency This study was developed in order to compare the thermal behavior of different types of roofs by measuring the External Surface Temperature (EST) and the Internal Surface Temperature (IST) over the days. The experimental design was completely randomized, with five treatments: AC - Asbestos cement tiles, BA -Bamboo tiles, BAP - Bamboo tiles painted in white, FB -Vegetable fiber tiles and bitumen, FBP -Vegetable fiber tiles and bitumen painted in white, with 15 repetitions, being adopted as repetitions the days of measurement. The temperature of the internal and external roofing surfaces was collected at 8:00 am, 10:00 am, 12:00 pm, 2:00 pm, 4:00 pm and 6:00 pm. Data were analyzed by SISVAR 5.1® program through the analysis of variance and Skott Knott test for comparison of means, significance level at 1%. The FB coverage showed the worst thermal performance compared to other types of coverage, with the best results observed in BAP coverage. 2017 artículo científico 0120-6230 https://www.redalyc.org/articulo.oa?id=43050083009 en http://www.redalyc.org/revista.oa?id=430 Revista Facultad de Ingeniería Universidad de Antioquia application/pdf Universidad de Antioquia Revista Facultad de Ingeniería Universidad de Antioquia (Colombia) Num.82
format Artículo científico
id redalyc_43050083009
institution Redalyc
language en
publishDate 2017
publisher Universidad de Antioquia
spellingShingle Thermal behavior of alternative materials used as roof and efficiency of the reflective painting on the external face
Eduardo Alves de Almeida
Ingeniería
bio
construction
sustainability
Thermal efficiency
Thermal behavior of alternative materials used as roof and efficiency of the reflective painting on the external face Eduardo Alves de Almeida Roberta Passini Ingeniería bio construction sustainability Thermal efficiency This study was developed in order to compare the thermal behavior of different types of roofs by measuring the External Surface Temperature (EST) and the Internal Surface Temperature (IST) over the days. The experimental design was completely randomized, with five treatments: AC - Asbestos cement tiles, BA -Bamboo tiles, BAP - Bamboo tiles painted in white, FB -Vegetable fiber tiles and bitumen, FBP -Vegetable fiber tiles and bitumen painted in white, with 15 repetitions, being adopted as repetitions the days of measurement. The temperature of the internal and external roofing surfaces was collected at 8:00 am, 10:00 am, 12:00 pm, 2:00 pm, 4:00 pm and 6:00 pm. Data were analyzed by SISVAR 5.1® program through the analysis of variance and Skott Knott test for comparison of means, significance level at 1%. The FB coverage showed the worst thermal performance compared to other types of coverage, with the best results observed in BAP coverage. 2017 artículo científico 0120-6230 https://www.redalyc.org/articulo.oa?id=43050083009 en http://www.redalyc.org/revista.oa?id=430 Revista Facultad de Ingeniería Universidad de Antioquia application/pdf Universidad de Antioquia Revista Facultad de Ingeniería Universidad de Antioquia (Colombia) Num.82
title Thermal behavior of alternative materials used as roof and efficiency of the reflective painting on the external face
topic Ingeniería
bio
construction
sustainability
Thermal efficiency
url https://www.redalyc.org/articulo.oa?id=43050083009