A comprehensive study of a similarity criterion in cardiac computerized tomography images enhancement

Fuente: Redalyc
Guardado en:
Detalles Bibliográficos
Autor principal: Antonio José Bravo Valero
Formato: Artículo científico
Lenguaje:en
Publicado: Universidad de Antioquia 2022
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1876438744783912960
author Antonio José Bravo Valero
author_facet Antonio José Bravo Valero
contents A comprehensive study of a similarity criterion in cardiac computerized tomography images enhancement Antonio José Bravo Valero Miguel Angel Vera Yoleidy Huérfano Yeison Fabian Manrique Hidalgo Ingeniería algorithms measurement data analysis data processing Medical technology This research focuses on the study of a particular filter based on a similarity criterion that has been applied to improve the information contained in images acquired using different cardiac imaging modalities. The primary attention of this study is to examine which component of the similarity criterion generates more relevant information useful to increase the medical image quality. In this sense, four case studies are established, first a complete formulation of the similarity criterion is considered, and then three additional cases, representing each component of the criterion; such cases are referred to as full, main, residual 1, and residual 2, respectively. A score function is used for quantifying and then assessing the impact of each component of the similarity criterion. Such measure is a relation between some full-reference and blind-reference image enhancement measures. A computer generated phantom and a representative clinical dataset (1,270 three-dimensional images from 126 patients) are used in a thorough evaluation of the similarity criterion. In general terms of performance of the image enhancement technique, the results of the study reveal that the component residual 1 outperforms than the other two components of similarity criterion or its complete formulation. 2022 artículo científico 0120-6230 https://www.redalyc.org/articulo.oa?id=43069426005 https://www.redalyc.org/journal/430/43069426005/ https://www.redalyc.org/journal/430/43069426005/html/ https://www.redalyc.org/journal/430/43069426005/43069426005.epub https://www.redalyc.org/journal/430/43069426005/movil 10.17533/udea.redin.20200799 en http://www.redalyc.org/revista.oa?id=430 Revista Facultad de Ingeniería Universidad de Antioquia application/pdf Universidad de Antioquia Revista Facultad de Ingeniería Universidad de Antioquia (Colombia) Num.102
format Artículo científico
id redalyc_43069426005
institution Redalyc
language en
publishDate 2022
publisher Universidad de Antioquia
spellingShingle A comprehensive study of a similarity criterion in cardiac computerized tomography images enhancement
Antonio José Bravo Valero
Ingeniería
algorithms
measurement
data analysis
data processing
Medical technology
A comprehensive study of a similarity criterion in cardiac computerized tomography images enhancement Antonio José Bravo Valero Miguel Angel Vera Yoleidy Huérfano Yeison Fabian Manrique Hidalgo Ingeniería algorithms measurement data analysis data processing Medical technology This research focuses on the study of a particular filter based on a similarity criterion that has been applied to improve the information contained in images acquired using different cardiac imaging modalities. The primary attention of this study is to examine which component of the similarity criterion generates more relevant information useful to increase the medical image quality. In this sense, four case studies are established, first a complete formulation of the similarity criterion is considered, and then three additional cases, representing each component of the criterion; such cases are referred to as full, main, residual 1, and residual 2, respectively. A score function is used for quantifying and then assessing the impact of each component of the similarity criterion. Such measure is a relation between some full-reference and blind-reference image enhancement measures. A computer generated phantom and a representative clinical dataset (1,270 three-dimensional images from 126 patients) are used in a thorough evaluation of the similarity criterion. In general terms of performance of the image enhancement technique, the results of the study reveal that the component residual 1 outperforms than the other two components of similarity criterion or its complete formulation. 2022 artículo científico 0120-6230 https://www.redalyc.org/articulo.oa?id=43069426005 https://www.redalyc.org/journal/430/43069426005/ https://www.redalyc.org/journal/430/43069426005/html/ https://www.redalyc.org/journal/430/43069426005/43069426005.epub https://www.redalyc.org/journal/430/43069426005/movil 10.17533/udea.redin.20200799 en http://www.redalyc.org/revista.oa?id=430 Revista Facultad de Ingeniería Universidad de Antioquia application/pdf Universidad de Antioquia Revista Facultad de Ingeniería Universidad de Antioquia (Colombia) Num.102
title A comprehensive study of a similarity criterion in cardiac computerized tomography images enhancement
topic Ingeniería
algorithms
measurement
data analysis
data processing
Medical technology
url https://www.redalyc.org/articulo.oa?id=43069426005
https://www.redalyc.org/journal/430/43069426005/
https://www.redalyc.org/journal/430/43069426005/html/
https://www.redalyc.org/journal/430/43069426005/43069426005.epub
https://www.redalyc.org/journal/430/43069426005/movil