NUMERICAL SIMULATION FOR CYCLIC STEAM INJECTION AT SANTA CLARA FIELD

Fuente: Redalyc
Salvato in:
Dettagli Bibliografici
Autore principale: Edwin Rodríguez
Natura: Artículo científico
Lingua:en
Pubblicazione: ECOPETROL S.A. 2008
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1876473093013110784
author Edwin Rodríguez
author_facet Edwin Rodríguez
contents NUMERICAL SIMULATION FOR CYCLIC STEAM INJECTION AT SANTA CLARA FIELD Edwin Rodríguez Wilson Barrios Roy Sandoval Nicolás Santos Ingrid Cortes Ingeniería laboratory test Santa Clara field numerical simulation sensitivity analysis Cyclic steam injection This article presents the methodology used and the results obtained in the construction, match and prediction of the first thermal composition simulation model done in Colombia by employing advanced thermal process commercial software, globally recognized because of its effectiveness in modeling these types of processes (CMG-STARS, 2005). The Santa Clara and Palermo fields were modeled and an excellent history match was achieved. All in all 28 wells and 17 years of production were matched. Two production scenes were proposed. The first involved primary production from existing wells, in other words: primary production; and a second escen where all the wells in the field are converted into injectors and producers, to simulate cyclic steam injection. This injection process included a series of sensitivity studies forseveral of the parameters involved in this technology, such as: pressure and temperature injection, time and rate of injection, heat injected, soaking period, steam quality, and injection cycles. This sensitivity study was focused on optimizing the processes to obtain the maximum end recovery possible. The information entered into the simulator was validated by laboratory tests developed at the Instituto Colombiano del Petróleo (ICP). Among the tests performed the following were assessed: rock compressibility, relative permeability curve behavior at different temperatures, formation sensitivity to injection fluids, DRX analysis and residual saturation of crude oil for steam injection. The aforementioned results are documented in this paper. 2008 artículo científico 0122-5383 https://www.redalyc.org/articulo.oa?id=46530407 en http://www.redalyc.org/revista.oa?id=465 CT&F Ciencia, Tecnología y Futuro application/pdf ECOPETROL S.A. CT&F Ciencia, Tecnología y Futuro (Colombia) Num.4 Vol.3
format Artículo científico
id redalyc_46530407
institution Redalyc
language en
publishDate 2008
publisher ECOPETROL S.A.
spellingShingle NUMERICAL SIMULATION FOR CYCLIC STEAM INJECTION AT SANTA CLARA FIELD
Edwin Rodríguez
Ingeniería
laboratory test
Santa Clara field
numerical simulation
sensitivity analysis
Cyclic steam injection
NUMERICAL SIMULATION FOR CYCLIC STEAM INJECTION AT SANTA CLARA FIELD Edwin Rodríguez Wilson Barrios Roy Sandoval Nicolás Santos Ingrid Cortes Ingeniería laboratory test Santa Clara field numerical simulation sensitivity analysis Cyclic steam injection This article presents the methodology used and the results obtained in the construction, match and prediction of the first thermal composition simulation model done in Colombia by employing advanced thermal process commercial software, globally recognized because of its effectiveness in modeling these types of processes (CMG-STARS, 2005). The Santa Clara and Palermo fields were modeled and an excellent history match was achieved. All in all 28 wells and 17 years of production were matched. Two production scenes were proposed. The first involved primary production from existing wells, in other words: primary production; and a second escen where all the wells in the field are converted into injectors and producers, to simulate cyclic steam injection. This injection process included a series of sensitivity studies forseveral of the parameters involved in this technology, such as: pressure and temperature injection, time and rate of injection, heat injected, soaking period, steam quality, and injection cycles. This sensitivity study was focused on optimizing the processes to obtain the maximum end recovery possible. The information entered into the simulator was validated by laboratory tests developed at the Instituto Colombiano del Petróleo (ICP). Among the tests performed the following were assessed: rock compressibility, relative permeability curve behavior at different temperatures, formation sensitivity to injection fluids, DRX analysis and residual saturation of crude oil for steam injection. The aforementioned results are documented in this paper. 2008 artículo científico 0122-5383 https://www.redalyc.org/articulo.oa?id=46530407 en http://www.redalyc.org/revista.oa?id=465 CT&F Ciencia, Tecnología y Futuro application/pdf ECOPETROL S.A. CT&F Ciencia, Tecnología y Futuro (Colombia) Num.4 Vol.3
title NUMERICAL SIMULATION FOR CYCLIC STEAM INJECTION AT SANTA CLARA FIELD
topic Ingeniería
laboratory test
Santa Clara field
numerical simulation
sensitivity analysis
Cyclic steam injection
url https://www.redalyc.org/articulo.oa?id=46530407