Improved Energy Conversion Process With Coupling Induction Motors And Invastigate Unbalanced Operation With Definition Of The Voltage Unbalance

Fuente: Redalyc
Saved in:
Bibliographic Details
Main Author: Hossin Rezaei Koopaei
Format: Artículo científico
Language:en
Published: Universidade Federal de Santa Maria 2015
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1876422307930439680
author Hossin Rezaei Koopaei
author_facet Hossin Rezaei Koopaei
contents Improved Energy Conversion Process With Coupling Induction Motors And Invastigate Unbalanced Operation With Definition Of The Voltage Unbalance Hossin Rezaei Koopaei Rahim Eildarabadi Mahmoud Zade Bagheri Estudios Ambientales DC motors Induction motor energy conversion unbalanced voltage This paper assesses Voltage unbalance study as one of power quality issues which is especially effected distribution voltages and is noteworthy. however it is possible that voltage in l evel of producing and transmission be balanced but this voltages in level of distribution can go out of balance and be unbalanced which is because of unbalanced systems, unequal impedances and lack of appropriate and balanced distribution of one phase load s in distribution systems occurs. In this thesis operation of steady state machine conjunction (Induction motor) under unbalanced voltage will be evaluated. Induction motors in small sizes attach as coupled and will be used instead of big sized induction m otors, which is proper for improved electromagnetic systems and more efficient energy conversion mechanism in both symmetric and asymmetric states. Two coupled induction motors can have the same or different rates mechanically. This thesis will analyze cou pled machinery using symmetric elements and MATLAB software. Definition of unbalance voltage is used by CVUF factor (complex voltage unbalance factor). Induction motors coupling with DC motors (direct current) is analyzed and coupling effect in electromagn etic torque in all system is studied and comparing of unbalanced voltage on standalone and coupled machines is demonstrateed. The purpose of such comparing is finding the best states in balanced and unbalanced working, also this thesis evaluates the effect of induction motors connection as coupling in energy conversion process. 2015 artículo científico 0100-8307 https://www.redalyc.org/articulo.oa?id=467547683039 en http://www.redalyc.org/revista.oa?id=4675 Ciência e Natura application/pdf Universidade Federal de Santa Maria Ciência e Natura (Brasil) Num.6-2 Vol.37
format Artículo científico
id redalyc_467547683039
institution Redalyc
language en
publishDate 2015
publisher Universidade Federal de Santa Maria
spellingShingle Improved Energy Conversion Process With Coupling Induction Motors And Invastigate Unbalanced Operation With Definition Of The Voltage Unbalance
Hossin Rezaei Koopaei
Estudios Ambientales
DC motors
Induction motor
energy conversion
unbalanced voltage
Improved Energy Conversion Process With Coupling Induction Motors And Invastigate Unbalanced Operation With Definition Of The Voltage Unbalance Hossin Rezaei Koopaei Rahim Eildarabadi Mahmoud Zade Bagheri Estudios Ambientales DC motors Induction motor energy conversion unbalanced voltage This paper assesses Voltage unbalance study as one of power quality issues which is especially effected distribution voltages and is noteworthy. however it is possible that voltage in l evel of producing and transmission be balanced but this voltages in level of distribution can go out of balance and be unbalanced which is because of unbalanced systems, unequal impedances and lack of appropriate and balanced distribution of one phase load s in distribution systems occurs. In this thesis operation of steady state machine conjunction (Induction motor) under unbalanced voltage will be evaluated. Induction motors in small sizes attach as coupled and will be used instead of big sized induction m otors, which is proper for improved electromagnetic systems and more efficient energy conversion mechanism in both symmetric and asymmetric states. Two coupled induction motors can have the same or different rates mechanically. This thesis will analyze cou pled machinery using symmetric elements and MATLAB software. Definition of unbalance voltage is used by CVUF factor (complex voltage unbalance factor). Induction motors coupling with DC motors (direct current) is analyzed and coupling effect in electromagn etic torque in all system is studied and comparing of unbalanced voltage on standalone and coupled machines is demonstrateed. The purpose of such comparing is finding the best states in balanced and unbalanced working, also this thesis evaluates the effect of induction motors connection as coupling in energy conversion process. 2015 artículo científico 0100-8307 https://www.redalyc.org/articulo.oa?id=467547683039 en http://www.redalyc.org/revista.oa?id=4675 Ciência e Natura application/pdf Universidade Federal de Santa Maria Ciência e Natura (Brasil) Num.6-2 Vol.37
title Improved Energy Conversion Process With Coupling Induction Motors And Invastigate Unbalanced Operation With Definition Of The Voltage Unbalance
topic Estudios Ambientales
DC motors
Induction motor
energy conversion
unbalanced voltage
url https://www.redalyc.org/articulo.oa?id=467547683039