Digital blood pressure monitor

Fuente: Redalyc
Gespeichert in:
Bibliographische Detailangaben
1. Verfasser: Rosendo Fuentes González
Format: Artículo científico
Sprache:en
Veröffentlicht: Universidad Nacional Autónoma de México 2004
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1876422762702045184
author Rosendo Fuentes González
author_facet Rosendo Fuentes González
contents Digital blood pressure monitor Rosendo Fuentes González Miguel Angel Bañuelos Saucedo Ingeniería Altera applications Blood pressure monitor Biomedical instrumentation In this work we present a blood pressure monitor which measures both the high blood pressure (systolic pressure),and the low blood pressure (diastolic pressure). It is a semiautomatic meter because the inflation of the occlusivecuff is carried out in a manual way. The transducer used is a piezoresistive silicon pressure sensor integrated onchip which provides a proportional voltage to the input pressure, with a measurement range from 0 to 50 kPa (0–7.3 PSI). The oscillometric method is employed, which consists on detecting the oscillometric signal on brachialartery, being processed at each pressure step, when the cuff is gradually deflated. Signal sampling is carried out ata rate determined by the heart rate.In order to program the digital electronics of the circuit we used Altera tools, with the compiler MAX-PLUS II, andthe device selected to implement the design was an EPM7128SLC84-15 CPLD (Complex Programmable LogicDevice) 2004 artículo científico 1665-6423 https://www.redalyc.org/articulo.oa?id=47402305 en http://www.redalyc.org/revista.oa?id=474 Journal of Applied Research and Technology application/pdf Universidad Nacional Autónoma de México Journal of Applied Research and Technology (México) Num.3 Vol.2
format Artículo científico
id redalyc_47402305
institution Redalyc
language en
publishDate 2004
publisher Universidad Nacional Autónoma de México
spellingShingle Digital blood pressure monitor
Rosendo Fuentes González
Ingeniería
Altera applications
Blood pressure monitor
Biomedical instrumentation
Digital blood pressure monitor Rosendo Fuentes González Miguel Angel Bañuelos Saucedo Ingeniería Altera applications Blood pressure monitor Biomedical instrumentation In this work we present a blood pressure monitor which measures both the high blood pressure (systolic pressure),and the low blood pressure (diastolic pressure). It is a semiautomatic meter because the inflation of the occlusivecuff is carried out in a manual way. The transducer used is a piezoresistive silicon pressure sensor integrated onchip which provides a proportional voltage to the input pressure, with a measurement range from 0 to 50 kPa (0–7.3 PSI). The oscillometric method is employed, which consists on detecting the oscillometric signal on brachialartery, being processed at each pressure step, when the cuff is gradually deflated. Signal sampling is carried out ata rate determined by the heart rate.In order to program the digital electronics of the circuit we used Altera tools, with the compiler MAX-PLUS II, andthe device selected to implement the design was an EPM7128SLC84-15 CPLD (Complex Programmable LogicDevice) 2004 artículo científico 1665-6423 https://www.redalyc.org/articulo.oa?id=47402305 en http://www.redalyc.org/revista.oa?id=474 Journal of Applied Research and Technology application/pdf Universidad Nacional Autónoma de México Journal of Applied Research and Technology (México) Num.3 Vol.2
title Digital blood pressure monitor
topic Ingeniería
Altera applications
Blood pressure monitor
Biomedical instrumentation
url https://www.redalyc.org/articulo.oa?id=47402305