Low noise low power readout circuit for soft X ray detection

Fuente: Redalyc
Saved in:
Bibliographic Details
Main Author: Alberto Cerdeira Estrada
Format: Artículo científico
Language:en
Published: Universidad Nacional Autónoma de México 2003
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1876486612250001408
author Alberto Cerdeira Estrada
author_facet Alberto Cerdeira Estrada
contents Low noise low power readout circuit for soft X ray detection Alberto Cerdeira Estrada Adriano De Luca Andres Cuttin R. Mutihac Ingeniería Sharper Equivalent noise charge Charge sensitive amplifiers A new low power CMOS ASIC for the detection of X-rays was optimized for low power and low noise. Theoretical calculations and optimizations are presented and compared with experimental results. Noise as low as 120+25*Cin [pF] ENC rms was obtained including a silicon detector of 1.3 pF and 0.3nA of leakage. The power consumption is less than 100 W. Other circuit parameters are also shown. 2003 artículo científico 1665-6423 https://www.redalyc.org/articulo.oa?id=47410301 en http://www.redalyc.org/revista.oa?id=474 Journal of Applied Research and Technology application/pdf Universidad Nacional Autónoma de México Journal of Applied Research and Technology (México) Num.3 Vol.1
format Artículo científico
id redalyc_47410301
institution Redalyc
language en
publishDate 2003
publisher Universidad Nacional Autónoma de México
spellingShingle Low noise low power readout circuit for soft X ray detection
Alberto Cerdeira Estrada
Ingeniería
Sharper
Equivalent noise charge
Charge sensitive amplifiers
Low noise low power readout circuit for soft X ray detection Alberto Cerdeira Estrada Adriano De Luca Andres Cuttin R. Mutihac Ingeniería Sharper Equivalent noise charge Charge sensitive amplifiers A new low power CMOS ASIC for the detection of X-rays was optimized for low power and low noise. Theoretical calculations and optimizations are presented and compared with experimental results. Noise as low as 120+25*Cin [pF] ENC rms was obtained including a silicon detector of 1.3 pF and 0.3nA of leakage. The power consumption is less than 100 W. Other circuit parameters are also shown. 2003 artículo científico 1665-6423 https://www.redalyc.org/articulo.oa?id=47410301 en http://www.redalyc.org/revista.oa?id=474 Journal of Applied Research and Technology application/pdf Universidad Nacional Autónoma de México Journal of Applied Research and Technology (México) Num.3 Vol.1
title Low noise low power readout circuit for soft X ray detection
topic Ingeniería
Sharper
Equivalent noise charge
Charge sensitive amplifiers
url https://www.redalyc.org/articulo.oa?id=47410301