Harmonic Mitigation using 36-Pulse AC-DC Converter for Direct Torque Controlled Induction Motor Drives

Fuente: Redalyc
Saved in:
Bibliographic Details
Main Author: R. Abdollahi
Format: Artículo científico
Language:en
Published: Universidad Nacional Autónoma de México 2015
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1876438062462926848
author R. Abdollahi
author_facet R. Abdollahi
contents Harmonic Mitigation using 36-Pulse AC-DC Converter for Direct Torque Controlled Induction Motor Drives R. Abdollahi Ingeniería AC 36 DC converter power quality pulse rectifier This paper presents the design and analysis of a transformer based 36-pulse ac-dc converters which supplies direct torque controlled induction motor drives (DTCIMD’s) in order to have better power quality conditions at the point of common coupling. The con verters output voltage is accomplished via two paralleled eighteen-pulse ac-dc converters each of them consisting of nine-phase diode bridge rectifier. The design procedure of magnetics is in a way such that makes it suitable for retrofit applications wher e a six-pulse diode bridge rectifier is being utilized. The 36-pulse structure improves power quality criteria at ac mains and makes them consistent with the IEEE-519 standard requirements for varying loads. Furthermore, near unity power factor is obtained for a wide range of DTCIMD operation. A comparison is made between 6-pulse and 36-pulse converters (Polygon, Fork, and Hexagon) from view point of power quality indices. Results show that input current total harmonic distortion (THD) is less than 4% for t he 36-pulse topologies at variable loads. The Delta/Hexagon connected platform could simplify the resulted configuration for the converters and reducing the costs. 2015 artículo científico 1665-6423 https://www.redalyc.org/articulo.oa?id=47436895013 en http://www.redalyc.org/revista.oa?id=474 Journal of Applied Research and Technology application/pdf Universidad Nacional Autónoma de México Journal of Applied Research and Technology (México) Num.1 Vol.13
format Artículo científico
id redalyc_47436895013
institution Redalyc
language en
publishDate 2015
publisher Universidad Nacional Autónoma de México
spellingShingle Harmonic Mitigation using 36-Pulse AC-DC Converter for Direct Torque Controlled Induction Motor Drives
R. Abdollahi
Ingeniería
AC
36
DC converter
power quality
pulse rectifier
Harmonic Mitigation using 36-Pulse AC-DC Converter for Direct Torque Controlled Induction Motor Drives R. Abdollahi Ingeniería AC 36 DC converter power quality pulse rectifier This paper presents the design and analysis of a transformer based 36-pulse ac-dc converters which supplies direct torque controlled induction motor drives (DTCIMD’s) in order to have better power quality conditions at the point of common coupling. The con verters output voltage is accomplished via two paralleled eighteen-pulse ac-dc converters each of them consisting of nine-phase diode bridge rectifier. The design procedure of magnetics is in a way such that makes it suitable for retrofit applications wher e a six-pulse diode bridge rectifier is being utilized. The 36-pulse structure improves power quality criteria at ac mains and makes them consistent with the IEEE-519 standard requirements for varying loads. Furthermore, near unity power factor is obtained for a wide range of DTCIMD operation. A comparison is made between 6-pulse and 36-pulse converters (Polygon, Fork, and Hexagon) from view point of power quality indices. Results show that input current total harmonic distortion (THD) is less than 4% for t he 36-pulse topologies at variable loads. The Delta/Hexagon connected platform could simplify the resulted configuration for the converters and reducing the costs. 2015 artículo científico 1665-6423 https://www.redalyc.org/articulo.oa?id=47436895013 en http://www.redalyc.org/revista.oa?id=474 Journal of Applied Research and Technology application/pdf Universidad Nacional Autónoma de México Journal of Applied Research and Technology (México) Num.1 Vol.13
title Harmonic Mitigation using 36-Pulse AC-DC Converter for Direct Torque Controlled Induction Motor Drives
topic Ingeniería
AC
36
DC converter
power quality
pulse rectifier
url https://www.redalyc.org/articulo.oa?id=47436895013