Reconstruction of three-dimensional breast-tumor model using multispectral gradient vector ow snake method

Fuente: Redalyc
Gespeichert in:
Bibliographische Detailangaben
1. Verfasser: Sheng-Chih Yang
Format: Artículo científico
Sprache:en
Veröffentlicht: Universidad Nacional Autónoma de México 2015
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1876486483136741376
author Sheng-Chih Yang
author_facet Sheng-Chih Yang
contents Reconstruction of three-dimensional breast-tumor model using multispectral gradient vector ow snake method Sheng-Chih Yang Cheng-Yi Yu Cheng-Jian Lin Hsueh-Yi Lin Chi-Yuan Lin Ingeniería Three contour detection breast needle localization breast magnetic resonance image dimensional model reconstruction In this study, we have proposed a three-dimensional (3D) model reconstruction system for breast tumors. The proposed system can establish an accurate 3D model of tumors, which will serve as a diagnostic reference for physicians and also address the shortcomings of the traditional breast needle localization method and other localization methods reported in previous studies. This developed system uses multispectral breast magnetic resonance images as input and detects the contour of the tumor in different sections using an active contour method — multispectral gradient vector ow snake (MGVFS) method. Thus, the system constructs a 3D model of only the tumor is contained in a breast surface model and excludes other tissues. Since the accuracy of the reconstructed 3D model depends on the accuracy of the tumor contour detection, for conrming the results obtained with the MGVFS method, we conducted experiments to evaluate its accuracy in contour detection, and compared the results with those traditional contour detection methods. Our results demonstrate that the MGVFS method has the highest accuracy in contour detection, with a correct contour detection rate as high as 99.79%. 2015 artículo científico 1665-6423 https://www.redalyc.org/articulo.oa?id=47439895014 en http://www.redalyc.org/revista.oa?id=474 Journal of Applied Research and Technology application/pdf Universidad Nacional Autónoma de México Journal of Applied Research and Technology (México) Num.2 Vol.13
format Artículo científico
id redalyc_47439895014
institution Redalyc
language en
publishDate 2015
publisher Universidad Nacional Autónoma de México
spellingShingle Reconstruction of three-dimensional breast-tumor model using multispectral gradient vector ow snake method
Sheng-Chih Yang
Ingeniería
Three
contour detection
breast needle localization
breast magnetic resonance image
dimensional model reconstruction
Reconstruction of three-dimensional breast-tumor model using multispectral gradient vector ow snake method Sheng-Chih Yang Cheng-Yi Yu Cheng-Jian Lin Hsueh-Yi Lin Chi-Yuan Lin Ingeniería Three contour detection breast needle localization breast magnetic resonance image dimensional model reconstruction In this study, we have proposed a three-dimensional (3D) model reconstruction system for breast tumors. The proposed system can establish an accurate 3D model of tumors, which will serve as a diagnostic reference for physicians and also address the shortcomings of the traditional breast needle localization method and other localization methods reported in previous studies. This developed system uses multispectral breast magnetic resonance images as input and detects the contour of the tumor in different sections using an active contour method — multispectral gradient vector ow snake (MGVFS) method. Thus, the system constructs a 3D model of only the tumor is contained in a breast surface model and excludes other tissues. Since the accuracy of the reconstructed 3D model depends on the accuracy of the tumor contour detection, for conrming the results obtained with the MGVFS method, we conducted experiments to evaluate its accuracy in contour detection, and compared the results with those traditional contour detection methods. Our results demonstrate that the MGVFS method has the highest accuracy in contour detection, with a correct contour detection rate as high as 99.79%. 2015 artículo científico 1665-6423 https://www.redalyc.org/articulo.oa?id=47439895014 en http://www.redalyc.org/revista.oa?id=474 Journal of Applied Research and Technology application/pdf Universidad Nacional Autónoma de México Journal of Applied Research and Technology (México) Num.2 Vol.13
title Reconstruction of three-dimensional breast-tumor model using multispectral gradient vector ow snake method
topic Ingeniería
Three
contour detection
breast needle localization
breast magnetic resonance image
dimensional model reconstruction
url https://www.redalyc.org/articulo.oa?id=47439895014