A novel isolated 36-pulse AC-DC converter for line current harmonic mitigation

Fuente: Redalyc
Gespeichert in:
Bibliographische Detailangaben
1. Verfasser: Rohollah Abdollahi
Format: Artículo científico
Sprache:en
Veröffentlicht: Universidad Nacional Autónoma de México 2018
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1876471626759929856
author Rohollah Abdollahi
author_facet Rohollah Abdollahi
contents A novel isolated 36-pulse AC-DC converter for line current harmonic mitigation Rohollah Abdollahi Ingeniería AC 36 delta DC converter power quality In this paper, a novel delta/tapped star transformer for 36-pulse AC-DC converter configuration is designed, modeled, simulated and developed to feed isolated DC varying loads. The proposed AC-DC converter is suitable for large current rating rectifiers such as electrowinning, electrochemical processes, induction heating, etc. Its main feature is its reduced kilovolt-ampere (kVA) rating. The circuit has been designed for retrofit applications, a delta/tapped star-connected transformer platform is also included in the converter. First, we have simulated the proposed scheme via Matlab/Simulink software supplying different load conditions. Then, it has been implemented based on the motivation we have gained throughout the simulation results. The results show significant improvement in power quality indices (according to the IEEE-519) at the point of connection to the utility. We achieve less than 4% of input current total harmonic distortion (THD) with our proposed configuration for supplying different load scenarios. Moreover, we achieve a satisfying power factor (almost unity) for DTCIMD operation. Also, a prototype of the proposed transformer-based 36-pulse ac–dc converter has been developed, and test results are presented to validate the developed design procedure and the simulation models of this ac–dc converter. 2018 artículo científico 1665-6423 https://www.redalyc.org/articulo.oa?id=47471655008 https://www.redalyc.org/journal/474/47471655008/ https://www.redalyc.org/journal/474/47471655008/html/ https://www.redalyc.org/journal/474/47471655008/47471655008.epub https://www.redalyc.org/journal/474/47471655008/movil 10.14482/INDES.30.1.303.661 en http://www.redalyc.org/revista.oa?id=474 Journal of Applied Research and Technology application/pdf Universidad Nacional Autónoma de México Journal of Applied Research and Technology (México) Num.4 Vol.16
format Artículo científico
id redalyc_47471655008
institution Redalyc
language en
publishDate 2018
publisher Universidad Nacional Autónoma de México
spellingShingle A novel isolated 36-pulse AC-DC converter for line current harmonic mitigation
Rohollah Abdollahi
Ingeniería
AC
36
delta
DC converter
power quality
A novel isolated 36-pulse AC-DC converter for line current harmonic mitigation Rohollah Abdollahi Ingeniería AC 36 delta DC converter power quality In this paper, a novel delta/tapped star transformer for 36-pulse AC-DC converter configuration is designed, modeled, simulated and developed to feed isolated DC varying loads. The proposed AC-DC converter is suitable for large current rating rectifiers such as electrowinning, electrochemical processes, induction heating, etc. Its main feature is its reduced kilovolt-ampere (kVA) rating. The circuit has been designed for retrofit applications, a delta/tapped star-connected transformer platform is also included in the converter. First, we have simulated the proposed scheme via Matlab/Simulink software supplying different load conditions. Then, it has been implemented based on the motivation we have gained throughout the simulation results. The results show significant improvement in power quality indices (according to the IEEE-519) at the point of connection to the utility. We achieve less than 4% of input current total harmonic distortion (THD) with our proposed configuration for supplying different load scenarios. Moreover, we achieve a satisfying power factor (almost unity) for DTCIMD operation. Also, a prototype of the proposed transformer-based 36-pulse ac–dc converter has been developed, and test results are presented to validate the developed design procedure and the simulation models of this ac–dc converter. 2018 artículo científico 1665-6423 https://www.redalyc.org/articulo.oa?id=47471655008 https://www.redalyc.org/journal/474/47471655008/ https://www.redalyc.org/journal/474/47471655008/html/ https://www.redalyc.org/journal/474/47471655008/47471655008.epub https://www.redalyc.org/journal/474/47471655008/movil 10.14482/INDES.30.1.303.661 en http://www.redalyc.org/revista.oa?id=474 Journal of Applied Research and Technology application/pdf Universidad Nacional Autónoma de México Journal of Applied Research and Technology (México) Num.4 Vol.16
title A novel isolated 36-pulse AC-DC converter for line current harmonic mitigation
topic Ingeniería
AC
36
delta
DC converter
power quality
url https://www.redalyc.org/articulo.oa?id=47471655008
https://www.redalyc.org/journal/474/47471655008/
https://www.redalyc.org/journal/474/47471655008/html/
https://www.redalyc.org/journal/474/47471655008/47471655008.epub
https://www.redalyc.org/journal/474/47471655008/movil