COMPARISON OF FREQUENCY RESPONSE AND NEURAL NETWORK TECHNIQUES FOR SYSTEM IDENTIFICATION OF AN ACTIVELY CONTROLLED STRUCTURE

Fuente: Redalyc
Enregistré dans:
Détails bibliographiques
Auteur principal: DANIEL GÓMEZ PIZANO
Format: Artículo científico
Langue:en
Publié: Universidad Nacional de Colombia 2011
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1876485810702778368
author DANIEL GÓMEZ PIZANO
author_facet DANIEL GÓMEZ PIZANO
contents COMPARISON OF FREQUENCY RESPONSE AND NEURAL NETWORK TECHNIQUES FOR SYSTEM IDENTIFICATION OF AN ACTIVELY CONTROLLED STRUCTURE DANIEL GÓMEZ PIZANO Ingeniería MISOsystem frequency response system identification artificial neural networks Structural dynamics and control System identification methodsare generally used to obtain the dynamic properties of structural systems. The dynamic properties are used for various purposes, such as model updating, structural health monitoring, and control synthesis. This paper presents the identification of an actively controlled structure with an active mass damper based on input- utputrelationships.The input signals include accelerations in the base of the structure and control force inputs while the output signals are the accelerations of the structure due to the inputs. In this paper, the system identification using frequency response functions iscompared with non-linear relationships obtained by using artificial neural networks (ANN) for bothasingle-input, single-output, and multiple-inputsingle-output (MISO) system. The results indicate that for the MISO structural system,the ANN technique providesa more accurate identification than identifications obtained with frequency responsemethods. 2011 artículo científico 0012-7353 https://www.redalyc.org/articulo.oa?id=49621159009 en http://www.redalyc.org/revista.oa?id=496 Dyna application/pdf Universidad Nacional de Colombia Dyna (Colombia) Num.170 Vol.78
format Artículo científico
id redalyc_49621159009
institution Redalyc
language en
publishDate 2011
publisher Universidad Nacional de Colombia
spellingShingle COMPARISON OF FREQUENCY RESPONSE AND NEURAL NETWORK TECHNIQUES FOR SYSTEM IDENTIFICATION OF AN ACTIVELY CONTROLLED STRUCTURE
DANIEL GÓMEZ PIZANO
Ingeniería
MISOsystem
frequency response
system identification
artificial neural networks
Structural dynamics and control
COMPARISON OF FREQUENCY RESPONSE AND NEURAL NETWORK TECHNIQUES FOR SYSTEM IDENTIFICATION OF AN ACTIVELY CONTROLLED STRUCTURE DANIEL GÓMEZ PIZANO Ingeniería MISOsystem frequency response system identification artificial neural networks Structural dynamics and control System identification methodsare generally used to obtain the dynamic properties of structural systems. The dynamic properties are used for various purposes, such as model updating, structural health monitoring, and control synthesis. This paper presents the identification of an actively controlled structure with an active mass damper based on input- utputrelationships.The input signals include accelerations in the base of the structure and control force inputs while the output signals are the accelerations of the structure due to the inputs. In this paper, the system identification using frequency response functions iscompared with non-linear relationships obtained by using artificial neural networks (ANN) for bothasingle-input, single-output, and multiple-inputsingle-output (MISO) system. The results indicate that for the MISO structural system,the ANN technique providesa more accurate identification than identifications obtained with frequency responsemethods. 2011 artículo científico 0012-7353 https://www.redalyc.org/articulo.oa?id=49621159009 en http://www.redalyc.org/revista.oa?id=496 Dyna application/pdf Universidad Nacional de Colombia Dyna (Colombia) Num.170 Vol.78
title COMPARISON OF FREQUENCY RESPONSE AND NEURAL NETWORK TECHNIQUES FOR SYSTEM IDENTIFICATION OF AN ACTIVELY CONTROLLED STRUCTURE
topic Ingeniería
MISOsystem
frequency response
system identification
artificial neural networks
Structural dynamics and control
url https://www.redalyc.org/articulo.oa?id=49621159009