COMPARISON BETWEEN RESONANT-COLUMN AND BENDER ELEMENT TESTS ON THREE TYPES OF SOILS

Fuente: Redalyc
Enregistré dans:
Détails bibliographiques
Auteur principal: JAVIER FERNANDO CAMACHO-TAUTA
Format: Artículo científico
Langue:en
Publié: Universidad Nacional de Colombia 2013
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1876474829896417280
author JAVIER FERNANDO CAMACHO-TAUTA
author_facet JAVIER FERNANDO CAMACHO-TAUTA
contents COMPARISON BETWEEN RESONANT-COLUMN AND BENDER ELEMENT TESTS ON THREE TYPES OF SOILS JAVIER FERNANDO CAMACHO-TAUTA OSCAR JAVER REYES-ORTIZ JUAN DAVID JIMÉNEZ ÁLVAREZ Ingeniería shear resonant column test shear modulus wave velocity The bender element (BE) test is used in laboratory to obtain the shear wave velocity of soils. Different execution and interpretation techniques have been proposed. However, there is not a specialized technique with an adequate level of accuracy and reproducibility to be adopted as a standard. Several factors affect the reliability of this method, mainly because of complex phenomena of wave propagation in the small volume of the specimen. Three type of soils were tested by Resonant-Column (RC) and two BE test methods (BETD and BEFD). Results suggest that in non-plastic soils the stiffness tends to be underestimated compared with the stiffness obtained by the RC test. The BETD method could be affected by the soil plasticity. The frequency domain method (BEFD) had less agreement with respect to the RC test. 2013 artículo científico 0012-7353 https://www.redalyc.org/articulo.oa?id=49629318021 en http://www.redalyc.org/revista.oa?id=496 Dyna application/pdf Universidad Nacional de Colombia Dyna (Colombia) Num.182 Vol.80
format Artículo científico
id redalyc_49629318021
institution Redalyc
language en
publishDate 2013
publisher Universidad Nacional de Colombia
spellingShingle COMPARISON BETWEEN RESONANT-COLUMN AND BENDER ELEMENT TESTS ON THREE TYPES OF SOILS
JAVIER FERNANDO CAMACHO-TAUTA
Ingeniería
shear
resonant
column test
shear modulus
wave velocity
COMPARISON BETWEEN RESONANT-COLUMN AND BENDER ELEMENT TESTS ON THREE TYPES OF SOILS JAVIER FERNANDO CAMACHO-TAUTA OSCAR JAVER REYES-ORTIZ JUAN DAVID JIMÉNEZ ÁLVAREZ Ingeniería shear resonant column test shear modulus wave velocity The bender element (BE) test is used in laboratory to obtain the shear wave velocity of soils. Different execution and interpretation techniques have been proposed. However, there is not a specialized technique with an adequate level of accuracy and reproducibility to be adopted as a standard. Several factors affect the reliability of this method, mainly because of complex phenomena of wave propagation in the small volume of the specimen. Three type of soils were tested by Resonant-Column (RC) and two BE test methods (BETD and BEFD). Results suggest that in non-plastic soils the stiffness tends to be underestimated compared with the stiffness obtained by the RC test. The BETD method could be affected by the soil plasticity. The frequency domain method (BEFD) had less agreement with respect to the RC test. 2013 artículo científico 0012-7353 https://www.redalyc.org/articulo.oa?id=49629318021 en http://www.redalyc.org/revista.oa?id=496 Dyna application/pdf Universidad Nacional de Colombia Dyna (Colombia) Num.182 Vol.80
title COMPARISON BETWEEN RESONANT-COLUMN AND BENDER ELEMENT TESTS ON THREE TYPES OF SOILS
topic Ingeniería
shear
resonant
column test
shear modulus
wave velocity
url https://www.redalyc.org/articulo.oa?id=49629318021