Effect of Different Silane Treatments on Long-Term Bonding Between Non-Etched Glass-Ceramic and Resin Cement

Fuente: Redalyc
Guardado en:
Detalles Bibliográficos
Autor principal: Fabián Murillo-Gómez
Formato: Artículo científico
Lenguaje:en
Publicado: Universidad de Costa Rica 2017
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1876465863561838592
author Fabián Murillo-Gómez
author_facet Fabián Murillo-Gómez
contents Effect of Different Silane Treatments on Long-Term Bonding Between Non-Etched Glass-Ceramic and Resin Cement Fabián Murillo-Gómez Mario F. De Goes Medicina Glass Multi Silane ceramics Cementation The present study evaluated the bond strength between glass-ceramic and resin cement, using different silane treatments, performing no previous hydrofluoric acid (HF) etching on ceramic surface, after short- and long- term storage. One hundred and eighty glass-ceramic plaques (IPS e.max CAD®) were polished and divided into six groups (n=30) to receive different silane treatments: (1) RCP-RelyX Ceramic Primer® (one-bottle silane), (2) RCP+SB-RelyX Ceramic Primer and Adper Singlebond2® (silane plus separated adhesive), (3) SBU-Scotchbond Universal® (silane-containing universal adhesive), (4) CP-Clearfil Ceramic Primer® (silane/MDP primer), (5) NC-no-silane (negative control) and (6) PC-Previous HF etching (5%, 20s) plus RelyX Ceramic Primer® (positive control). Two resin cement cylinders (Rely X Ultimate®) were built on each plaque. Each group was divided into two sub-groups to be stored for 24 hours (24h) or 6 months (6mo) in distilled water at 37°C (n=15). Then microshear (µSBS) testing was performed. Failure mode was analyzed using scanning electron microscopy (SEM). Data were statistically analyzed by two-way ANOVA and Tukey´s test (α=0.05). Both factors and their interaction resulted statistically significant (p≤0.05). PC obtained the highest µSBS values (in MPa) at both storage times (24h: 28.11±2.44; 6mo: 19.10±3.85). After 24h storage, groups RCP+SB (10.86±3.62), SBU (8.37±4.33) and CP (8.05±3.62) were not statistically different from NC (8.00±2.51); only RCP (19.73±4.63) and PC obtained higher values. After 6 months, only PC showed higher values than NC (0.04±0.01). Cohesive failure in resin cement was more prevalent for RCP-24h and PC, while adhesive failure was more frequent among all other groups. Clinical relevance: None of the commercially available silane primers tested, improve long- term ceramic/cement bonding without performing HF etching on ceramic surface. Combination of HF acid and silane, remain as a gold standard treatment for glass-ceramic materials. 2017 artículo científico 1659-1046 https://www.redalyc.org/articulo.oa?id=499555012004 https://www.redalyc.org/journal/4995/499555012004/ https://www.redalyc.org/journal/4995/499555012004/html/ https://www.redalyc.org/journal/4995/499555012004/499555012004.epub https://www.redalyc.org/journal/4995/499555012004/movil 10.15517/ijds.v19i2.27950 en http://www.redalyc.org/revista.oa?id=4995 Odovtos - International Journal of Dental Sciences application/pdf Universidad de Costa Rica Odovtos - International Journal of Dental Sciences (Costa Rica) Num.2 Vol.19
format Artículo científico
id redalyc_499555012004
institution Redalyc
language en
publishDate 2017
publisher Universidad de Costa Rica
spellingShingle Effect of Different Silane Treatments on Long-Term Bonding Between Non-Etched Glass-Ceramic and Resin Cement
Fabián Murillo-Gómez
Medicina
Glass
Multi
Silane
ceramics
Cementation
Effect of Different Silane Treatments on Long-Term Bonding Between Non-Etched Glass-Ceramic and Resin Cement Fabián Murillo-Gómez Mario F. De Goes Medicina Glass Multi Silane ceramics Cementation The present study evaluated the bond strength between glass-ceramic and resin cement, using different silane treatments, performing no previous hydrofluoric acid (HF) etching on ceramic surface, after short- and long- term storage. One hundred and eighty glass-ceramic plaques (IPS e.max CAD®) were polished and divided into six groups (n=30) to receive different silane treatments: (1) RCP-RelyX Ceramic Primer® (one-bottle silane), (2) RCP+SB-RelyX Ceramic Primer and Adper Singlebond2® (silane plus separated adhesive), (3) SBU-Scotchbond Universal® (silane-containing universal adhesive), (4) CP-Clearfil Ceramic Primer® (silane/MDP primer), (5) NC-no-silane (negative control) and (6) PC-Previous HF etching (5%, 20s) plus RelyX Ceramic Primer® (positive control). Two resin cement cylinders (Rely X Ultimate®) were built on each plaque. Each group was divided into two sub-groups to be stored for 24 hours (24h) or 6 months (6mo) in distilled water at 37°C (n=15). Then microshear (µSBS) testing was performed. Failure mode was analyzed using scanning electron microscopy (SEM). Data were statistically analyzed by two-way ANOVA and Tukey´s test (α=0.05). Both factors and their interaction resulted statistically significant (p≤0.05). PC obtained the highest µSBS values (in MPa) at both storage times (24h: 28.11±2.44; 6mo: 19.10±3.85). After 24h storage, groups RCP+SB (10.86±3.62), SBU (8.37±4.33) and CP (8.05±3.62) were not statistically different from NC (8.00±2.51); only RCP (19.73±4.63) and PC obtained higher values. After 6 months, only PC showed higher values than NC (0.04±0.01). Cohesive failure in resin cement was more prevalent for RCP-24h and PC, while adhesive failure was more frequent among all other groups. Clinical relevance: None of the commercially available silane primers tested, improve long- term ceramic/cement bonding without performing HF etching on ceramic surface. Combination of HF acid and silane, remain as a gold standard treatment for glass-ceramic materials. 2017 artículo científico 1659-1046 https://www.redalyc.org/articulo.oa?id=499555012004 https://www.redalyc.org/journal/4995/499555012004/ https://www.redalyc.org/journal/4995/499555012004/html/ https://www.redalyc.org/journal/4995/499555012004/499555012004.epub https://www.redalyc.org/journal/4995/499555012004/movil 10.15517/ijds.v19i2.27950 en http://www.redalyc.org/revista.oa?id=4995 Odovtos - International Journal of Dental Sciences application/pdf Universidad de Costa Rica Odovtos - International Journal of Dental Sciences (Costa Rica) Num.2 Vol.19
title Effect of Different Silane Treatments on Long-Term Bonding Between Non-Etched Glass-Ceramic and Resin Cement
topic Medicina
Glass
Multi
Silane
ceramics
Cementation
url https://www.redalyc.org/articulo.oa?id=499555012004
https://www.redalyc.org/journal/4995/499555012004/
https://www.redalyc.org/journal/4995/499555012004/html/
https://www.redalyc.org/journal/4995/499555012004/499555012004.epub
https://www.redalyc.org/journal/4995/499555012004/movil