Salvato in:
Dettagli Bibliografici
Autore principale: Tugba Serin-Kalay
Natura: Artículo científico
Lingua:en
Pubblicazione: Universidad de Costa Rica 2022
Soggetti:
Accesso online:https://www.redalyc.org/articulo.oa?id=499570300007
https://www.redalyc.org/journal/4995/499570300007/
https://www.redalyc.org/journal/4995/499570300007/html/
https://www.redalyc.org/journal/4995/499570300007/499570300007.epub
https://www.redalyc.org/journal/4995/499570300007/movil
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
Sommario:
  • Effect of Alternative Self-Etch Applications on Dentin Bond Strength of “No Wait Concept” Universal Adhesives Tugba Serin-Kalay Beyza Zaim Medicina Microtensile Application time Application mode Universal adhesives Dentin bond strength This study evaluated the effects of alternative self-etch application modes on resin-dentin microtensile bond strength (µTBS) of three commercially available “no wait” concept universal adhesives. In this study extracted impacted non-carious human third molars were used. The flat surfaces were prepared in mid-coronal dentin and prepared with a 600-grit SiC paper. The three universal adhesives that were used are as follows: Clearfil Universal Bond Quick (CUQ, Kuraray Noritake, Japan), G-Premio Bond (GPB, GC Corp, Japan), and a self-curing universal adhesive “Tokuyama Universal Bond” (TUB; Tokuyama Dental, Japan). The following three different application procedures were used for the dentin surfaces: the adhesives were applied and immediately subjected to air-dry; the adhesives were applied followed by a 10-second wait; or the adhesives were rubbed for 10 seconds. Then composite resin was applied to the dentin surface and light cured. After storage in 37°C distilled water for 24 h, all the bonded teeth were cut into 1mm² sections using a low-speed diamond saw (Micracut 125 Low Speed Precision Cutter, Metkon, Bursa, Turkey) under running water (n=15). The sections were subjected to a tensile force at a crosshead speed of 1mm/min in a testing apparatus (Microtensile Tester, Bisco, IL, USA) and µTBS values were measured. Data were analyzed using the Kruskal-Wallis test and Mann-Whitney U test. Failure modes were analyzed under a stereomicroscope. Prolonged application time significantly affected the µTBS (p<0.005). A significant increase of µTBS on active application was observed for CUQ and GPB. The TUB with an active application had a significantly lower µTBS value compared with the other adhesives. Prolonged application time caused significant improvement of bond strength in all adhesives. The active application is effective at increasing the dentin bond strength except for TUB. 2022 artículo científico 1659-1046 https://www.redalyc.org/articulo.oa?id=499570300007 https://www.redalyc.org/journal/4995/499570300007/ https://www.redalyc.org/journal/4995/499570300007/html/ https://www.redalyc.org/journal/4995/499570300007/499570300007.epub https://www.redalyc.org/journal/4995/499570300007/movil 10.15517/IJDS.2021.45844 en http://www.redalyc.org/revista.oa?id=4995 Odovtos - International Journal of Dental Sciences application/pdf Universidad de Costa Rica Odovtos - International Journal of Dental Sciences (Costa Rica) Num.1 Vol.24