Concentration of heavy metals in condensed atmospheric water vapor at three Mexican localities

Fuente: Redalyc
Enregistré dans:
Détails bibliographiques
Auteur principal: Ana Laura Bautista-Olivas
Format: Artículo científico
Langue:en
Publié: Universidad Nacional Autónoma de México 2017
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1876488095845580800
author Ana Laura Bautista-Olivas
author_facet Ana Laura Bautista-Olivas
contents Concentration of heavy metals in condensed atmospheric water vapor at three Mexican localities Ana Laura Bautista-Olivas Fidencio Cruz-Bautista Clara Rosalía Álvarez-Chávez Andrea Guadalupe Zavala-Reyna Luz Amelia Sánchez-Landero Juana Alvarado-Ibarra Biología Trace ions water quality hygroscopicity active condenser atmospheric water vapor The condensation of water vapor is a very useful technique in mitigating the scarcity of water resources for human consumption; however, the quality of this water must meet the highest standards to avoid becoming a health hazard. The present study quantifies trace elements such as As, Ba, Cu, Cd, Cr, Fe, Hg, Mn, Pb, and Zn, as well as pH and electrical conductivity (EC), in condensed atmospheric water vapor at three localities in Mexico. Atmospheric water vapor was condensed with an atmospheric water generator prototype. A total of 108 samples were obtained from three survey sites over the course of two seasons (wet and dry) during day/night shifts. The concentration of heavy metals was analyzed using inductively coupled plasma mass spectrometry. The pH and EC parameters were measured with a potentiometer/conductometer. We found Pb, Fe, and Cd in 91.66, 58.33, and 33% of the samples, respectively, at concentrations exceeding those permitted by the World Health Organization (WHO) for water intended for human consumption. Both pH and EC were within the limits established by the Department of Water Affairs of Namibia. The concentrations of trace metals in condensed atmospheric water vapor samples were within the maximum permissible limits determined by WHO for most elements analyzed in this study. 2017 artículo científico 0187-6236 https://www.redalyc.org/articulo.oa?id=56554836003 https://www.redalyc.org/journal/565/56554836003/ https://www.redalyc.org/journal/565/56554836003/html/ https://www.redalyc.org/journal/565/56554836003/56554836003.epub https://www.redalyc.org/journal/565/56554836003/movil https://doi.org/10.20937/ATM.2017.30.03.02 en http://www.redalyc.org/revista.oa?id=565 Atmósfera application/pdf Universidad Nacional Autónoma de México Atmósfera (México) Num.3 Vol.30
format Artículo científico
id redalyc_56554836003
institution Redalyc
language en
publishDate 2017
publisher Universidad Nacional Autónoma de México
spellingShingle Concentration of heavy metals in condensed atmospheric water vapor at three Mexican localities
Ana Laura Bautista-Olivas
Biología
Trace ions
water quality
hygroscopicity
active condenser
atmospheric water vapor
Concentration of heavy metals in condensed atmospheric water vapor at three Mexican localities Ana Laura Bautista-Olivas Fidencio Cruz-Bautista Clara Rosalía Álvarez-Chávez Andrea Guadalupe Zavala-Reyna Luz Amelia Sánchez-Landero Juana Alvarado-Ibarra Biología Trace ions water quality hygroscopicity active condenser atmospheric water vapor The condensation of water vapor is a very useful technique in mitigating the scarcity of water resources for human consumption; however, the quality of this water must meet the highest standards to avoid becoming a health hazard. The present study quantifies trace elements such as As, Ba, Cu, Cd, Cr, Fe, Hg, Mn, Pb, and Zn, as well as pH and electrical conductivity (EC), in condensed atmospheric water vapor at three localities in Mexico. Atmospheric water vapor was condensed with an atmospheric water generator prototype. A total of 108 samples were obtained from three survey sites over the course of two seasons (wet and dry) during day/night shifts. The concentration of heavy metals was analyzed using inductively coupled plasma mass spectrometry. The pH and EC parameters were measured with a potentiometer/conductometer. We found Pb, Fe, and Cd in 91.66, 58.33, and 33% of the samples, respectively, at concentrations exceeding those permitted by the World Health Organization (WHO) for water intended for human consumption. Both pH and EC were within the limits established by the Department of Water Affairs of Namibia. The concentrations of trace metals in condensed atmospheric water vapor samples were within the maximum permissible limits determined by WHO for most elements analyzed in this study. 2017 artículo científico 0187-6236 https://www.redalyc.org/articulo.oa?id=56554836003 https://www.redalyc.org/journal/565/56554836003/ https://www.redalyc.org/journal/565/56554836003/html/ https://www.redalyc.org/journal/565/56554836003/56554836003.epub https://www.redalyc.org/journal/565/56554836003/movil https://doi.org/10.20937/ATM.2017.30.03.02 en http://www.redalyc.org/revista.oa?id=565 Atmósfera application/pdf Universidad Nacional Autónoma de México Atmósfera (México) Num.3 Vol.30
title Concentration of heavy metals in condensed atmospheric water vapor at three Mexican localities
topic Biología
Trace ions
water quality
hygroscopicity
active condenser
atmospheric water vapor
url https://www.redalyc.org/articulo.oa?id=56554836003
https://www.redalyc.org/journal/565/56554836003/
https://www.redalyc.org/journal/565/56554836003/html/
https://www.redalyc.org/journal/565/56554836003/56554836003.epub
https://www.redalyc.org/journal/565/56554836003/movil
https://doi.org/10.20937/ATM.2017.30.03.02