Salvato in:
Dettagli Bibliografici
Autore principale: L. Godínez
Natura: Artículo científico
Lingua:en
Pubblicazione: Universidad Nacional Autónoma de México 2002
Soggetti:
Accesso online:https://www.redalyc.org/articulo.oa?id=56841308
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866814301489070080
author L. Godínez
author_facet L. Godínez
contents Indoor radon and airborne particles L. Godínez G. Ponciano W. Ruiz N. Segovia Ciencias de la Tierra smoking Indoor radon automatic devices airborne particles short term monitoring Daily radon fluctuations were monitored in dwellings located in the State of Mexico and in Mexico City in order to assessthe expected fluctuations in a short term monitoring basis. The radon monitoring was performed with Honeywell A9000 A devicesthat record radon and daughters using silicon detectors. Airborne particle fluctuations were also determined using a Personal Data-Logging Real-time Aerosol Monitor. The results indicate an indoor radon average value of 22 Bq/m3. Discrete values one order ofmagnitude higher than the mean were observed, mainly between midnight and early morning. The airborne particles in the bedroomshowed daily average values of 0.08 mg/m3. Experiments with smokers indicated fluctuations in the airborne particle concentrationsthat depend on the ventilation and the number of smokers in the room. 2002 artículo científico 0016-7169 https://www.redalyc.org/articulo.oa?id=56841308 en http://www.redalyc.org/revista.oa?id=568 Geofísica Internacional application/pdf Universidad Nacional Autónoma de México Geofísica Internacional (México) Num.3 Vol.41
format Artículo científico
id redalyc_56841308
language en
publishDate 2002
publisher Universidad Nacional Autónoma de México
spellingShingle Indoor radon and airborne particles
L. Godínez
Ciencias de la Tierra
smoking
Indoor radon
automatic devices
airborne particles
short term monitoring
Indoor radon and airborne particles L. Godínez G. Ponciano W. Ruiz N. Segovia Ciencias de la Tierra smoking Indoor radon automatic devices airborne particles short term monitoring Daily radon fluctuations were monitored in dwellings located in the State of Mexico and in Mexico City in order to assessthe expected fluctuations in a short term monitoring basis. The radon monitoring was performed with Honeywell A9000 A devicesthat record radon and daughters using silicon detectors. Airborne particle fluctuations were also determined using a Personal Data-Logging Real-time Aerosol Monitor. The results indicate an indoor radon average value of 22 Bq/m3. Discrete values one order ofmagnitude higher than the mean were observed, mainly between midnight and early morning. The airborne particles in the bedroomshowed daily average values of 0.08 mg/m3. Experiments with smokers indicated fluctuations in the airborne particle concentrationsthat depend on the ventilation and the number of smokers in the room. 2002 artículo científico 0016-7169 https://www.redalyc.org/articulo.oa?id=56841308 en http://www.redalyc.org/revista.oa?id=568 Geofísica Internacional application/pdf Universidad Nacional Autónoma de México Geofísica Internacional (México) Num.3 Vol.41