- Indoor radon and airborne particles L. Godínez G. Ponciano W. Ruiz N. Segovia Ciencias de la Tierra smoking Indoor radon automatic devices airborne particles short term monitoring Daily radon fluctuations were monitored in dwellings located in the State of Mexico and in Mexico City in order to assessthe expected fluctuations in a short term monitoring basis. The radon monitoring was performed with Honeywell A9000 A devicesthat record radon and daughters using silicon detectors. Airborne particle fluctuations were also determined using a Personal Data-Logging Real-time Aerosol Monitor. The results indicate an indoor radon average value of 22 Bq/m3. Discrete values one order ofmagnitude higher than the mean were observed, mainly between midnight and early morning. The airborne particles in the bedroomshowed daily average values of 0.08 mg/m3. Experiments with smokers indicated fluctuations in the airborne particle concentrationsthat depend on the ventilation and the number of smokers in the room. 2002 artículo científico 0016-7169 https://www.redalyc.org/articulo.oa?id=56841308 en http://www.redalyc.org/revista.oa?id=568 Geofísica Internacional application/pdf Universidad Nacional Autónoma de México Geofísica Internacional (México) Num.3 Vol.41