Calorimetric measurements of AC looses in Bi-2213/Ag multifilament tape

Fuente: Redalyc
Gespeichert in:
Bibliographische Detailangaben
1. Verfasser: M. Ramos
Format: Artículo científico
Sprache:en
Veröffentlicht: Sociedad Mexicana de Física A.C. 2010
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1876437440874414080
author M. Ramos
author_facet M. Ramos
contents Calorimetric measurements of AC looses in Bi-2213/Ag multifilament tape M. Ramos J. Schwartz U. Trociewitz S. Pamidi S. Flores Física, Astronomía y Matemáticas nitrogen AC losses calorimetric superconductor We present research work collaboration between the University of Texas at El Paso and The National High Magnetic Field Laboratory. This work presents a series of measurements of AC losses in multi-filamentary Bi-2223/Ag tapes using a calorimetric method as described by Ashworth and Suenaga. The AC losses were investigated at liquid nitrogen temperatures (77 K) for different AC currents and in frequency range form 50 Hz to 500 Hz. The results are compared with the Norris ellipse model for calculating self-field loss in high temperature superconducting tape. 2010 artículo científico 0035-001X https://www.redalyc.org/articulo.oa?id=57016006012 en http://www.redalyc.org/revista.oa?id=570 Revista Mexicana de Física application/pdf Sociedad Mexicana de Física A.C. Revista Mexicana de Física (México) Num.2 Vol.56
format Artículo científico
id redalyc_57016006012
institution Redalyc
language en
publishDate 2010
publisher Sociedad Mexicana de Física A.C.
spellingShingle Calorimetric measurements of AC looses in Bi-2213/Ag multifilament tape
M. Ramos
Física, Astronomía y Matemáticas
nitrogen
AC losses
calorimetric
superconductor
Calorimetric measurements of AC looses in Bi-2213/Ag multifilament tape M. Ramos J. Schwartz U. Trociewitz S. Pamidi S. Flores Física, Astronomía y Matemáticas nitrogen AC losses calorimetric superconductor We present research work collaboration between the University of Texas at El Paso and The National High Magnetic Field Laboratory. This work presents a series of measurements of AC losses in multi-filamentary Bi-2223/Ag tapes using a calorimetric method as described by Ashworth and Suenaga. The AC losses were investigated at liquid nitrogen temperatures (77 K) for different AC currents and in frequency range form 50 Hz to 500 Hz. The results are compared with the Norris ellipse model for calculating self-field loss in high temperature superconducting tape. 2010 artículo científico 0035-001X https://www.redalyc.org/articulo.oa?id=57016006012 en http://www.redalyc.org/revista.oa?id=570 Revista Mexicana de Física application/pdf Sociedad Mexicana de Física A.C. Revista Mexicana de Física (México) Num.2 Vol.56
title Calorimetric measurements of AC looses in Bi-2213/Ag multifilament tape
topic Física, Astronomía y Matemáticas
nitrogen
AC losses
calorimetric
superconductor
url https://www.redalyc.org/articulo.oa?id=57016006012