Guardado en:
Detalles Bibliográficos
Autor principal: B. Riquelme
Formato: Artículo científico
Lenguaje:en
Publicado: Sociedad Mexicana de Física A.C. 2006
Materias:
Acceso en línea:https://www.redalyc.org/articulo.oa?id=57028295021
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866585757737549824
author B. Riquelme
author_facet B. Riquelme
contents Optical sensor for the quantification of monoclonal antibodies B. Riquelme O. Rubio J. Valverde Física, Astronomía y Matemáticas immunosensor Laser reflectometry Langmuir adsorption An optical sensor for the quantification of a monoclonal antibody (MoAb) in solution by the reflectometry technique is shown in this work. A silicon wafer was chosen as a reflecting surface. An amount of AB blood group antibody (anti–AB) is added to the sample when the pseudo Brewster angle of incidence has been fixed. The reflected laser intensity is registered in real time as the protein is being adsorbed onto the wafer. The mathematical analysis of the results verifies that the antibody adsorption follows Langmuir's kinetics. From the curve analysis, the parameters related to the anti–AB concentration are extracted and the calibration curve is constructed. This curve allows us to obtain the desired commercial antiserum quantification. 2006 artículo científico 0035-001X https://www.redalyc.org/articulo.oa?id=57028295021 en http://www.redalyc.org/revista.oa?id=570 Revista Mexicana de Física application/pdf Sociedad Mexicana de Física A.C. Revista Mexicana de Física (México) Num.2 Vol.52
format Artículo científico
id redalyc_57028295021
language en
publishDate 2006
publisher Sociedad Mexicana de Física A.C.
spellingShingle Optical sensor for the quantification of monoclonal antibodies
B. Riquelme
Física, Astronomía y Matemáticas
immunosensor
Laser reflectometry
Langmuir adsorption
Optical sensor for the quantification of monoclonal antibodies B. Riquelme O. Rubio J. Valverde Física, Astronomía y Matemáticas immunosensor Laser reflectometry Langmuir adsorption An optical sensor for the quantification of a monoclonal antibody (MoAb) in solution by the reflectometry technique is shown in this work. A silicon wafer was chosen as a reflecting surface. An amount of AB blood group antibody (anti–AB) is added to the sample when the pseudo Brewster angle of incidence has been fixed. The reflected laser intensity is registered in real time as the protein is being adsorbed onto the wafer. The mathematical analysis of the results verifies that the antibody adsorption follows Langmuir's kinetics. From the curve analysis, the parameters related to the anti–AB concentration are extracted and the calibration curve is constructed. This curve allows us to obtain the desired commercial antiserum quantification. 2006 artículo científico 0035-001X https://www.redalyc.org/articulo.oa?id=57028295021 en http://www.redalyc.org/revista.oa?id=570 Revista Mexicana de Física application/pdf Sociedad Mexicana de Física A.C. Revista Mexicana de Física (México) Num.2 Vol.52
title Optical sensor for the quantification of monoclonal antibodies
topic Física, Astronomía y Matemáticas
immunosensor
Laser reflectometry
Langmuir adsorption
url https://www.redalyc.org/articulo.oa?id=57028295021