Saved in:
Bibliographic Details
Main Author: M. Ley-Koo
Format: Artículo científico
Language:en
Published: Sociedad Mexicana de Física A.C. 2006
Subjects:
Online Access:https://www.redalyc.org/articulo.oa?id=57065115
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866558505863872512
author M. Ley-Koo
author_facet M. Ley-Koo
contents High signal-to-noise ratio wedges for oblique incidence in ultrasonic testing M. Ley-Koo S. Salazar-Cruz Física, Astronomía y Matemáticas wedges reflection ultrasonics transmission Oblique incidence It is experimentally shown that ultrasonic transmission through a column of couplant, with a thin film, at the end, produces greater amplitudesthan through a piece of acrylic with the same length. This suggests the use of a wedge that could yield a greater signal-to-noise ratio thanthat of commercial wedges involved in oblique incidence ultrasonic inspection. The suggestion has been pursued, and the effects: on a weldare presented. 2006 artículo científico 0035-001X https://www.redalyc.org/articulo.oa?id=57065115 en http://www.redalyc.org/revista.oa?id=570 Revista Mexicana de Física application/pdf Sociedad Mexicana de Física A.C. Revista Mexicana de Física (México) Num.3 Vol.52
format Artículo científico
id redalyc_57065115
language en
publishDate 2006
publisher Sociedad Mexicana de Física A.C.
spellingShingle High signal-to-noise ratio wedges for oblique incidence in ultrasonic testing
M. Ley-Koo
Física, Astronomía y Matemáticas
wedges
reflection
ultrasonics
transmission
Oblique incidence
High signal-to-noise ratio wedges for oblique incidence in ultrasonic testing M. Ley-Koo S. Salazar-Cruz Física, Astronomía y Matemáticas wedges reflection ultrasonics transmission Oblique incidence It is experimentally shown that ultrasonic transmission through a column of couplant, with a thin film, at the end, produces greater amplitudesthan through a piece of acrylic with the same length. This suggests the use of a wedge that could yield a greater signal-to-noise ratio thanthat of commercial wedges involved in oblique incidence ultrasonic inspection. The suggestion has been pursued, and the effects: on a weldare presented. 2006 artículo científico 0035-001X https://www.redalyc.org/articulo.oa?id=57065115 en http://www.redalyc.org/revista.oa?id=570 Revista Mexicana de Física application/pdf Sociedad Mexicana de Física A.C. Revista Mexicana de Física (México) Num.3 Vol.52
title High signal-to-noise ratio wedges for oblique incidence in ultrasonic testing
topic Física, Astronomía y Matemáticas
wedges
reflection
ultrasonics
transmission
Oblique incidence
url https://www.redalyc.org/articulo.oa?id=57065115