Clinical validation study of the SignCare Vital Signs Monitor of Fundación Cardiovascular de Colombia

Fuente: Redalyc
Gespeichert in:
Bibliographische Detailangaben
1. Verfasser: Leonardo Andrés Rodríguez-Salazar
Format: Artículo científico
Sprache:en
Veröffentlicht: Universidad Nacional de Colombia 2016
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1876483456347668480
author Leonardo Andrés Rodríguez-Salazar
author_facet Leonardo Andrés Rodríguez-Salazar
contents Clinical validation study of the SignCare Vital Signs Monitor of Fundación Cardiovascular de Colombia Leonardo Andrés Rodríguez-Salazar Edna Magaly Gamboa-Delgado Sherneyko Plata-Rangel Oscar Alberto Mantilla-Prada Eugenio Sarmiento-Caraballo José Domingo Rincón-Riveros Medicina Vital Sign Physiologic Monitoring Validation Studies (MeSH) Introduction: In Colombia, due to the difficult access to health services and to geographic conditions, the implementation and innovation of telemedicine technological tools is a priority. Having a validated vital signs monitor (VSM) improves proper medical treatment and diagnosis. Objective: To design and perform clinical trials for the SignCare VSM.Materials and methods: A device for continuous monitoring of electrocardiography, respiration, oxygen saturation, temperature and noninvasive blood pressure (NIBP) was designed. This device was validated in a laboratory in order to ensure a robust prototype, close to the level of commercial medical devices. Clinical trials were performed through a cross -section study with 98 patients, whose vital signs were measured using the SignCare monitor and a commercial monitor. These two measurements were compared using Pearson's correlation coefficients. Results: There were no statistically significant differences between the results obtained with the SignCare VSM and the commercial monitor. The highest correlations were found for the following items: heart rate by electrocardiogram (r=0.844), heart rate by oxymetry (r=0.821), body temperature (r=0.895), systolic blood pressure (r=0.780), and diastolic blood pressure (r=0.811). Conclusions: The SignCare device is as reliable as the commercial monitor in the qualitative detection of morphologic alterations of electrocardiogram records, as well as in breathing, temperature, oxygen saturation and blood pressure parameters, which makes it recommendable for clinical use in adult population. 2016 artículo científico 2357-3848 https://www.redalyc.org/articulo.oa?id=576364352010 https://www.redalyc.org/journal/5763/576364352010/ https://www.redalyc.org/journal/5763/576364352010/html/ https://www.redalyc.org/journal/5763/576364352010/576364352010.epub https://www.redalyc.org/journal/5763/576364352010/movil 10.15446/revfacmed.v64n3.49339 en http://www.redalyc.org/revista.oa?id=5763 Revista de la Facultad de Medicina application/pdf Universidad Nacional de Colombia Revista de la Facultad de Medicina (Colombia) Num.3 Vol.64
format Artículo científico
id redalyc_576364352010
institution Redalyc
language en
publishDate 2016
publisher Universidad Nacional de Colombia
spellingShingle Clinical validation study of the SignCare Vital Signs Monitor of Fundación Cardiovascular de Colombia
Leonardo Andrés Rodríguez-Salazar
Medicina
Vital Sign
Physiologic Monitoring
Validation Studies (MeSH)
Clinical validation study of the SignCare Vital Signs Monitor of Fundación Cardiovascular de Colombia Leonardo Andrés Rodríguez-Salazar Edna Magaly Gamboa-Delgado Sherneyko Plata-Rangel Oscar Alberto Mantilla-Prada Eugenio Sarmiento-Caraballo José Domingo Rincón-Riveros Medicina Vital Sign Physiologic Monitoring Validation Studies (MeSH) Introduction: In Colombia, due to the difficult access to health services and to geographic conditions, the implementation and innovation of telemedicine technological tools is a priority. Having a validated vital signs monitor (VSM) improves proper medical treatment and diagnosis. Objective: To design and perform clinical trials for the SignCare VSM.Materials and methods: A device for continuous monitoring of electrocardiography, respiration, oxygen saturation, temperature and noninvasive blood pressure (NIBP) was designed. This device was validated in a laboratory in order to ensure a robust prototype, close to the level of commercial medical devices. Clinical trials were performed through a cross -section study with 98 patients, whose vital signs were measured using the SignCare monitor and a commercial monitor. These two measurements were compared using Pearson's correlation coefficients. Results: There were no statistically significant differences between the results obtained with the SignCare VSM and the commercial monitor. The highest correlations were found for the following items: heart rate by electrocardiogram (r=0.844), heart rate by oxymetry (r=0.821), body temperature (r=0.895), systolic blood pressure (r=0.780), and diastolic blood pressure (r=0.811). Conclusions: The SignCare device is as reliable as the commercial monitor in the qualitative detection of morphologic alterations of electrocardiogram records, as well as in breathing, temperature, oxygen saturation and blood pressure parameters, which makes it recommendable for clinical use in adult population. 2016 artículo científico 2357-3848 https://www.redalyc.org/articulo.oa?id=576364352010 https://www.redalyc.org/journal/5763/576364352010/ https://www.redalyc.org/journal/5763/576364352010/html/ https://www.redalyc.org/journal/5763/576364352010/576364352010.epub https://www.redalyc.org/journal/5763/576364352010/movil 10.15446/revfacmed.v64n3.49339 en http://www.redalyc.org/revista.oa?id=5763 Revista de la Facultad de Medicina application/pdf Universidad Nacional de Colombia Revista de la Facultad de Medicina (Colombia) Num.3 Vol.64
title Clinical validation study of the SignCare Vital Signs Monitor of Fundación Cardiovascular de Colombia
topic Medicina
Vital Sign
Physiologic Monitoring
Validation Studies (MeSH)
url https://www.redalyc.org/articulo.oa?id=576364352010
https://www.redalyc.org/journal/5763/576364352010/
https://www.redalyc.org/journal/5763/576364352010/html/
https://www.redalyc.org/journal/5763/576364352010/576364352010.epub
https://www.redalyc.org/journal/5763/576364352010/movil