Torque estimation based on surface electromyography: potential tool for knee rehabilitation
Fuente:
Redalyc
Guardado en:
| Autor principal: | |
|---|---|
| Formato: | Artículo científico |
| Lenguaje: | en |
| Publicado: |
Universidad Nacional de Colombia
2020
|
| Materias: | |
| Acceso en línea: | |
| Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
| _version_ | 1876481869923483648 |
|---|---|
| author | Mario Andrés Portela |
| author_facet | Mario Andrés Portela |
| contents | Torque estimation based on surface electromyography: potential tool for knee rehabilitation Mario Andrés Portela Juanita Irina Sánchez-Romero Vera Zasúlich Pérez Manuel José Betancur Medicina Torque Knee Joint Electromyography Muscle Contraction (MeSH) Introduction: Multiple signal processing studies have reported the application of surface electromyography (sEMG) signals in robotics and motor rehabilitation processes. Objective: To conduct a literature review on the use of sEMG signals as an alternative method for knee torque estimation in order to objectively measure the progress of patients at different stages of knee injury rehabilitation.Materials and methods: A literature review of studies published between 1986 and 2018, without geographical limits, was carried out in the Engineering Village, IEEE Xplore, Science-Direct, Web of Science, Scopus, and PubMed databases by combining 8 search terms. Results: After completing the initial search, 355 records were retrieved. Duplicated publications were eliminated, and 308 articles were analyzed to determine if they met the inclusion criteria. Finally, 18 studies describing, in a comparative way, how to estimate torque based on sEMG signals were included.Conclusion: The use of sEMG signals to calculate joint torque is an alternative method that allows therapists to obtain quantitative parameters and assess the progress of patients undergoing knee rehabilitation processes. 2020 artículo científico 2357-3848 https://www.redalyc.org/articulo.oa?id=576366603015 https://www.redalyc.org/journal/5763/576366603015/ https://www.redalyc.org/journal/5763/576366603015/html/ https://www.redalyc.org/journal/5763/576366603015/576366603015.epub https://www.redalyc.org/journal/5763/576366603015/movil 10.15446/revfacmed.v68n3.75214 en http://www.redalyc.org/revista.oa?id=5763 Revista de la Facultad de Medicina application/pdf Universidad Nacional de Colombia Revista de la Facultad de Medicina (Colombia) Num.3 Vol.68 |
| format | Artículo científico |
| id | redalyc_576366603015 |
| institution | Redalyc |
| language | en |
| publishDate | 2020 |
| publisher | Universidad Nacional de Colombia |
| spellingShingle | Torque estimation based on surface electromyography: potential tool for knee rehabilitation Mario Andrés Portela Medicina Torque Knee Joint Electromyography Muscle Contraction (MeSH) Torque estimation based on surface electromyography: potential tool for knee rehabilitation Mario Andrés Portela Juanita Irina Sánchez-Romero Vera Zasúlich Pérez Manuel José Betancur Medicina Torque Knee Joint Electromyography Muscle Contraction (MeSH) Introduction: Multiple signal processing studies have reported the application of surface electromyography (sEMG) signals in robotics and motor rehabilitation processes. Objective: To conduct a literature review on the use of sEMG signals as an alternative method for knee torque estimation in order to objectively measure the progress of patients at different stages of knee injury rehabilitation.Materials and methods: A literature review of studies published between 1986 and 2018, without geographical limits, was carried out in the Engineering Village, IEEE Xplore, Science-Direct, Web of Science, Scopus, and PubMed databases by combining 8 search terms. Results: After completing the initial search, 355 records were retrieved. Duplicated publications were eliminated, and 308 articles were analyzed to determine if they met the inclusion criteria. Finally, 18 studies describing, in a comparative way, how to estimate torque based on sEMG signals were included.Conclusion: The use of sEMG signals to calculate joint torque is an alternative method that allows therapists to obtain quantitative parameters and assess the progress of patients undergoing knee rehabilitation processes. 2020 artículo científico 2357-3848 https://www.redalyc.org/articulo.oa?id=576366603015 https://www.redalyc.org/journal/5763/576366603015/ https://www.redalyc.org/journal/5763/576366603015/html/ https://www.redalyc.org/journal/5763/576366603015/576366603015.epub https://www.redalyc.org/journal/5763/576366603015/movil 10.15446/revfacmed.v68n3.75214 en http://www.redalyc.org/revista.oa?id=5763 Revista de la Facultad de Medicina application/pdf Universidad Nacional de Colombia Revista de la Facultad de Medicina (Colombia) Num.3 Vol.68 |
| title | Torque estimation based on surface electromyography: potential tool for knee rehabilitation |
| topic | Medicina Torque Knee Joint Electromyography Muscle Contraction (MeSH) |
| url | https://www.redalyc.org/articulo.oa?id=576366603015 https://www.redalyc.org/journal/5763/576366603015/ https://www.redalyc.org/journal/5763/576366603015/html/ https://www.redalyc.org/journal/5763/576366603015/576366603015.epub https://www.redalyc.org/journal/5763/576366603015/movil |