New Proposal of Correction Factors for dc Voltages

Fuente: Redalyc
Enregistré dans:
Détails bibliographiques
Auteur principal: P. A. Calva Chavarría
Format: Artículo científico
Langue:en
Publié: Instituto Politécnico Nacional 2005
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1876485344405225472
author P. A. Calva Chavarría
author_facet P. A. Calva Chavarría
contents New Proposal of Correction Factors for dc Voltages P. A. Calva Chavarría V. del del Moral G. P. Cabrera J. de la Rosa Ingeniería 1995 IEEE Std IEC 60060 high altitudes dc high voltages The IEC-60-1989 and IEEE Std. 4-1995 procedures for dcvoltages are not suitable for high altitudes. The assumptionthat the streamer propagation field varies linearly with therelative air density does not apply to high-altitude dcbreakdown. Recently it has been published some work relatedto the positive polarity, in this paper, finally, considering bothpositive and negative polarities a new proposal of correctionfactors for dc voltages is presented. It has been concludedthat the effect of air density and humidity can be accountedfor independently, that in positive polarity it is necessary tocorrect both for relative air density and for humidity, but innegative polarity only by relative air density, furthermore, agap factor for different arrangements of electrodes isintroduced. 2005 artículo científico 1665-0654 https://www.redalyc.org/articulo.oa?id=61490303 en http://www.redalyc.org/revista.oa?id=614 Científica application/pdf Instituto Politécnico Nacional Científica (México) Num.3 Vol.9
format Artículo científico
id redalyc_61490303
institution Redalyc
language en
publishDate 2005
publisher Instituto Politécnico Nacional
spellingShingle New Proposal of Correction Factors for dc Voltages
P. A. Calva Chavarría
Ingeniería
1995
IEEE Std
IEC 60060
high altitudes
dc high voltages
New Proposal of Correction Factors for dc Voltages P. A. Calva Chavarría V. del del Moral G. P. Cabrera J. de la Rosa Ingeniería 1995 IEEE Std IEC 60060 high altitudes dc high voltages The IEC-60-1989 and IEEE Std. 4-1995 procedures for dcvoltages are not suitable for high altitudes. The assumptionthat the streamer propagation field varies linearly with therelative air density does not apply to high-altitude dcbreakdown. Recently it has been published some work relatedto the positive polarity, in this paper, finally, considering bothpositive and negative polarities a new proposal of correctionfactors for dc voltages is presented. It has been concludedthat the effect of air density and humidity can be accountedfor independently, that in positive polarity it is necessary tocorrect both for relative air density and for humidity, but innegative polarity only by relative air density, furthermore, agap factor for different arrangements of electrodes isintroduced. 2005 artículo científico 1665-0654 https://www.redalyc.org/articulo.oa?id=61490303 en http://www.redalyc.org/revista.oa?id=614 Científica application/pdf Instituto Politécnico Nacional Científica (México) Num.3 Vol.9
title New Proposal of Correction Factors for dc Voltages
topic Ingeniería
1995
IEEE Std
IEC 60060
high altitudes
dc high voltages
url https://www.redalyc.org/articulo.oa?id=61490303