Salvato in:
Dettagli Bibliografici
Autore principale: Romeu Fuscaldi
Natura: Artículo científico
Lingua:en
Pubblicazione: Universidad Nacional de Colombia 2011
Soggetti:
Accesso online:https://www.redalyc.org/articulo.oa?id=64322338022
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866812522319839232
author Romeu Fuscaldi
author_facet Romeu Fuscaldi
contents Power Quality Problems Caused by Termites on 138-kV Underground Cables Romeu Fuscaldi Fernando H. Silveira Alberto De Conti Silvério Visacro Ingeniería termites underground cables Transmission systems This paper discusses problems found in the operation of underground cables in the transmission system of CEMIG, with emphasis on insulation failures caused by termites. This problem has been the source of many scheduled and nonscheduled interruptions in later years, leading to significant maintenance costs. Experience with current practices designed to detect and prevent this failure mode is described. It is argued that new procedures are needed for improved on-line, pre-failure detection. Test improvement will hopefully contribute to increase the lifetime of underground cables currently in use, as well as to reduce maintenance costs.. 2011 artículo científico 0120-5609 https://www.redalyc.org/articulo.oa?id=64322338022 en http://www.redalyc.org/revista.oa?id=643 Ingeniería e Investigación application/pdf Universidad Nacional de Colombia Ingeniería e Investigación (Colombia) Num.2 Vol.31
format Artículo científico
id redalyc_64322338022
language en
publishDate 2011
publisher Universidad Nacional de Colombia
spellingShingle Power Quality Problems Caused by Termites on 138-kV Underground Cables
Romeu Fuscaldi
Ingeniería
termites
underground cables
Transmission systems
Power Quality Problems Caused by Termites on 138-kV Underground Cables Romeu Fuscaldi Fernando H. Silveira Alberto De Conti Silvério Visacro Ingeniería termites underground cables Transmission systems This paper discusses problems found in the operation of underground cables in the transmission system of CEMIG, with emphasis on insulation failures caused by termites. This problem has been the source of many scheduled and nonscheduled interruptions in later years, leading to significant maintenance costs. Experience with current practices designed to detect and prevent this failure mode is described. It is argued that new procedures are needed for improved on-line, pre-failure detection. Test improvement will hopefully contribute to increase the lifetime of underground cables currently in use, as well as to reduce maintenance costs.. 2011 artículo científico 0120-5609 https://www.redalyc.org/articulo.oa?id=64322338022 en http://www.redalyc.org/revista.oa?id=643 Ingeniería e Investigación application/pdf Universidad Nacional de Colombia Ingeniería e Investigación (Colombia) Num.2 Vol.31
title Power Quality Problems Caused by Termites on 138-kV Underground Cables
topic Ingeniería
termites
underground cables
Transmission systems
url https://www.redalyc.org/articulo.oa?id=64322338022