Saved in:
Bibliographic Details
Main Author: Jonė Jackevičiūtė
Format: Artículo científico
Language:en
Published: Vilniaus Universitetas 2019
Subjects:
Online Access:https://www.redalyc.org/articulo.oa?id=694073931007
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866581794876293120
author Jonė Jackevičiūtė
author_facet Jonė Jackevičiūtė
contents Comparison of two continuous non-invasive haemodynamic monitoring techniques in the perioperative setting Jonė Jackevičiūtė Greta Kraujalytė Inna Jaremko Vilija Stremaitytė Jūratė Gudaitytė Medicina non invasive bioimpedance cardiac output intraoperative Background. The aim of the study was to identify the accuracy of and agreement between two non-invasive haemodynamic monitoring techniques in the perioperative setting – thoracic electrical bioimpedance (TEB) and Edwards Lifesciences ClearSight system (CS). Materials and methods. The study included ten patients. Parametric quantitative data were expressed as mean ± SD. The ShapiroWilk test was used to test the normality of the distributions. A linear regression model was used to measure the strength of the linear relationship between TEB and CS. Bland-Altman analysis was performed to assess the mean difference, precision, and the limits of agreements (LOA). The Critchley and Critchley method was used to calculate the percentage error (PE), and if <30%, it was considered clinically acceptable. Results. Ten patients were involved in our study. The mean cardiac output (CO) with TEB was 6.15 ± 1.14 L/min vs. 4.78 ± 1.40 L/min with CS (p < 0.01). The relationship was significant (n = 144; r2 = 0.7; p < 0.01). The mean bias, LOA, and PE were 1.37 ± 1.01 L/min, 3.35 L/min and –0.61 L/min and 36.22%, respectively. The mean stroke volume index (SVI) with TEB was 48.64 ± 9.8 ml/beat/m2 vs. 37.12 ± 9.14 ml/beat/m2 with CS (p < 0.01). The relationship was significant (n = 144; r2 = 0.65; p < 0.01). The mean bias, LOA, and PE were 11.52 ± 7.92 ml/beat/m2, 27.04 ml/beat/m2 and –4 ml/beat/m2 and 36.19%. Conclusions. The two methods of non-invasive haemodynamic monitoring are not compatible in the perioperative setting. However, the CS system has more advantages in terms of continuity and simplicity of monitoring, while measurements of TEB are interrupted by electrocautery. 2019 artículo científico 2029-4174 https://www.redalyc.org/articulo.oa?id=694073931007 10.6001/actamedica.v26i1.3953. en http://www.redalyc.org/revista.oa?id=6940 Acta medica Lituanica application/pdf Vilniaus Universitetas Acta medica Lituanica (Lituania) Num.1 Vol.26
format Artículo científico
id redalyc_694073931007
language en
publishDate 2019
publisher Vilniaus Universitetas
spellingShingle Comparison of two continuous non-invasive haemodynamic monitoring techniques in the perioperative setting
Jonė Jackevičiūtė
Medicina
non
invasive
bioimpedance
cardiac output
intraoperative
Comparison of two continuous non-invasive haemodynamic monitoring techniques in the perioperative setting Jonė Jackevičiūtė Greta Kraujalytė Inna Jaremko Vilija Stremaitytė Jūratė Gudaitytė Medicina non invasive bioimpedance cardiac output intraoperative Background. The aim of the study was to identify the accuracy of and agreement between two non-invasive haemodynamic monitoring techniques in the perioperative setting – thoracic electrical bioimpedance (TEB) and Edwards Lifesciences ClearSight system (CS). Materials and methods. The study included ten patients. Parametric quantitative data were expressed as mean ± SD. The ShapiroWilk test was used to test the normality of the distributions. A linear regression model was used to measure the strength of the linear relationship between TEB and CS. Bland-Altman analysis was performed to assess the mean difference, precision, and the limits of agreements (LOA). The Critchley and Critchley method was used to calculate the percentage error (PE), and if <30%, it was considered clinically acceptable. Results. Ten patients were involved in our study. The mean cardiac output (CO) with TEB was 6.15 ± 1.14 L/min vs. 4.78 ± 1.40 L/min with CS (p < 0.01). The relationship was significant (n = 144; r2 = 0.7; p < 0.01). The mean bias, LOA, and PE were 1.37 ± 1.01 L/min, 3.35 L/min and –0.61 L/min and 36.22%, respectively. The mean stroke volume index (SVI) with TEB was 48.64 ± 9.8 ml/beat/m2 vs. 37.12 ± 9.14 ml/beat/m2 with CS (p < 0.01). The relationship was significant (n = 144; r2 = 0.65; p < 0.01). The mean bias, LOA, and PE were 11.52 ± 7.92 ml/beat/m2, 27.04 ml/beat/m2 and –4 ml/beat/m2 and 36.19%. Conclusions. The two methods of non-invasive haemodynamic monitoring are not compatible in the perioperative setting. However, the CS system has more advantages in terms of continuity and simplicity of monitoring, while measurements of TEB are interrupted by electrocautery. 2019 artículo científico 2029-4174 https://www.redalyc.org/articulo.oa?id=694073931007 10.6001/actamedica.v26i1.3953. en http://www.redalyc.org/revista.oa?id=6940 Acta medica Lituanica application/pdf Vilniaus Universitetas Acta medica Lituanica (Lituania) Num.1 Vol.26
title Comparison of two continuous non-invasive haemodynamic monitoring techniques in the perioperative setting
topic Medicina
non
invasive
bioimpedance
cardiac output
intraoperative
url https://www.redalyc.org/articulo.oa?id=694073931007