Impact on dosimetry of occupationally exposed individuals on the patient management for PET/MRI studies: a comparison study with dosimetry on PET/CT

Fuente: Redalyc
Enregistré dans:
Détails bibliographiques
Auteur principal: E. N. Itikawa
Format: Artículo científico
Langue:en
Publié: Sociedade Brasileira de Proteção Radiológica - SBPR 2023
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1876476969550348288
author E. N. Itikawa
author_facet E. N. Itikawa
contents Impact on dosimetry of occupationally exposed individuals on the patient management for PET/MRI studies: a comparison study with dosimetry on PET/CT E. N. Itikawa H. S. Videira U. Souza-Fonda P. S. Pires R. Mondin I. Bortoleti M. I. C. Guimarães C. A. Buchpiguel Biología TLD Exposure Dosimeter Medical Physics PET/MRI technology has expanded the boundaries of investigation in nuclear medicine, supported by the high sensitivity of solid-state PET detectors. Nonetheless, the coil positioning might lead to an increased exposure period of the worker to the injected patient. This procedure does not occur on PET/CT and, therefore, exposure period is reduced on such scanner. The aim of our study was to evaluate the dosimetry of two occupationally exposed individuals (OEI) working at the Center of Nuclear Medicine of Hospital das Clínicas of the University of Sao Paulo. We used thermoluminescent (TLD) dosimeters in pulse, whole-body and crystalline for PET/MRI and PET/CT procedures during five months of clinical and research routine. We also monitored the time for positioning/removing the patient on both scanners. For this study, OEI1 performed 76 PET/MRI studies and 102 PET/CT studies while OEI2 performed 26 and 56 PET/MRI and PET/CT studies, respectively. We found no evidence of differences for the whole-body dose values between both scanners (p = 0.22). The average time of patient management (positioning/removing the patient) was 14.38, and 3.81 minutes for PET/MRI and PET/CT, respectively. When the normalization by the number of PET/CT studies was applied, we found no statistical difference for effective and equivalent dose values. Our study encourages future investigations on nursing staff, which is a critical population that is exposed to ionizing radiation, mainly on dynamic studies, due to the synchronized injection with the protocol starting. 2023 artículo científico 2319-0612 https://www.redalyc.org/articulo.oa?id=722277919004 https://www.redalyc.org/journal/7222/722277919004/ https://www.redalyc.org/journal/7222/722277919004/html/ https://www.redalyc.org/journal/7222/722277919004/722277919004.epub https://www.redalyc.org/journal/7222/722277919004/movil https://doi.org/10.15392/2319-0612.2023.2154 en http://www.redalyc.org/revista.oa?id=7222 Brazilian Journal of Radiation Sciences application/pdf Sociedade Brasileira de Proteção Radiológica - SBPR Brazilian Journal of Radiation Sciences (Brasil) Num.2 Vol.11
format Artículo científico
id redalyc_722277919004
institution Redalyc
language en
publishDate 2023
publisher Sociedade Brasileira de Proteção Radiológica - SBPR
spellingShingle Impact on dosimetry of occupationally exposed individuals on the patient management for PET/MRI studies: a comparison study with dosimetry on PET/CT
E. N. Itikawa
Biología
TLD
Exposure
Dosimeter
Medical Physics
Impact on dosimetry of occupationally exposed individuals on the patient management for PET/MRI studies: a comparison study with dosimetry on PET/CT E. N. Itikawa H. S. Videira U. Souza-Fonda P. S. Pires R. Mondin I. Bortoleti M. I. C. Guimarães C. A. Buchpiguel Biología TLD Exposure Dosimeter Medical Physics PET/MRI technology has expanded the boundaries of investigation in nuclear medicine, supported by the high sensitivity of solid-state PET detectors. Nonetheless, the coil positioning might lead to an increased exposure period of the worker to the injected patient. This procedure does not occur on PET/CT and, therefore, exposure period is reduced on such scanner. The aim of our study was to evaluate the dosimetry of two occupationally exposed individuals (OEI) working at the Center of Nuclear Medicine of Hospital das Clínicas of the University of Sao Paulo. We used thermoluminescent (TLD) dosimeters in pulse, whole-body and crystalline for PET/MRI and PET/CT procedures during five months of clinical and research routine. We also monitored the time for positioning/removing the patient on both scanners. For this study, OEI1 performed 76 PET/MRI studies and 102 PET/CT studies while OEI2 performed 26 and 56 PET/MRI and PET/CT studies, respectively. We found no evidence of differences for the whole-body dose values between both scanners (p = 0.22). The average time of patient management (positioning/removing the patient) was 14.38, and 3.81 minutes for PET/MRI and PET/CT, respectively. When the normalization by the number of PET/CT studies was applied, we found no statistical difference for effective and equivalent dose values. Our study encourages future investigations on nursing staff, which is a critical population that is exposed to ionizing radiation, mainly on dynamic studies, due to the synchronized injection with the protocol starting. 2023 artículo científico 2319-0612 https://www.redalyc.org/articulo.oa?id=722277919004 https://www.redalyc.org/journal/7222/722277919004/ https://www.redalyc.org/journal/7222/722277919004/html/ https://www.redalyc.org/journal/7222/722277919004/722277919004.epub https://www.redalyc.org/journal/7222/722277919004/movil https://doi.org/10.15392/2319-0612.2023.2154 en http://www.redalyc.org/revista.oa?id=7222 Brazilian Journal of Radiation Sciences application/pdf Sociedade Brasileira de Proteção Radiológica - SBPR Brazilian Journal of Radiation Sciences (Brasil) Num.2 Vol.11
title Impact on dosimetry of occupationally exposed individuals on the patient management for PET/MRI studies: a comparison study with dosimetry on PET/CT
topic Biología
TLD
Exposure
Dosimeter
Medical Physics
url https://www.redalyc.org/articulo.oa?id=722277919004
https://www.redalyc.org/journal/7222/722277919004/
https://www.redalyc.org/journal/7222/722277919004/html/
https://www.redalyc.org/journal/7222/722277919004/722277919004.epub
https://www.redalyc.org/journal/7222/722277919004/movil
https://doi.org/10.15392/2319-0612.2023.2154