Quality control of radiotherapy treatment plans with electrons

Fuente: Redalyc
Gespeichert in:
Bibliographische Detailangaben
1. Verfasser: Luciana Tourinho Campos
Format: Artículo científico
Sprache:en
Veröffentlicht: Sociedade Brasileira de Proteção Radiológica - SBPR 2019
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1876488602527989760
author Luciana Tourinho Campos
author_facet Luciana Tourinho Campos
contents Quality control of radiotherapy treatment plans with electrons Luciana Tourinho Campos Luiz Ribeiro da Rosa Delano Valdivino Batista Delson Braz Biología EGSnrc Radiotherapy Monte Carlo dosimetry In this work, the quality of the treatment planning generated by Eclipse commercial treatment planning system for electron beams of energy 9 and 20 MeV was verified and their accuracy in the calculation of dose distributions for several clinical situations was evaluated. Tests cases had been developed according to the Brazilian reality, having as reference the radiotherapy treatments carried out in the Instituto Nacional do Câncer. The system developed for checking the quality of treatment planning systems with electrons was efficient in evaluating the Eclipse planning system by identifying the failures of their algorithms, especially in planning the isodose. The verification system has been validated against the Monte Carlo method and the experimental data with an ionization chamber and showed the shortcomings of generalized pencil beam and eMC algorithms. The deviation of the results obtained with the Monte Carlo in relation to the eMC algorithm is higher than 3%, taking into account the statistical fluctuation inherent in the system in some case tests. 2019 artículo científico 2319-0612 https://www.redalyc.org/articulo.oa?id=722280831002 en http://www.redalyc.org/revista.oa?id=7222 Brazilian Journal of Radiation Sciences application/pdf Sociedade Brasileira de Proteção Radiológica - SBPR Brazilian Journal of Radiation Sciences (Brasil) Num.1 Vol.7
format Artículo científico
id redalyc_722280831002
institution Redalyc
language en
publishDate 2019
publisher Sociedade Brasileira de Proteção Radiológica - SBPR
spellingShingle Quality control of radiotherapy treatment plans with electrons
Luciana Tourinho Campos
Biología
EGSnrc
Radiotherapy
Monte Carlo dosimetry
Quality control of radiotherapy treatment plans with electrons Luciana Tourinho Campos Luiz Ribeiro da Rosa Delano Valdivino Batista Delson Braz Biología EGSnrc Radiotherapy Monte Carlo dosimetry In this work, the quality of the treatment planning generated by Eclipse commercial treatment planning system for electron beams of energy 9 and 20 MeV was verified and their accuracy in the calculation of dose distributions for several clinical situations was evaluated. Tests cases had been developed according to the Brazilian reality, having as reference the radiotherapy treatments carried out in the Instituto Nacional do Câncer. The system developed for checking the quality of treatment planning systems with electrons was efficient in evaluating the Eclipse planning system by identifying the failures of their algorithms, especially in planning the isodose. The verification system has been validated against the Monte Carlo method and the experimental data with an ionization chamber and showed the shortcomings of generalized pencil beam and eMC algorithms. The deviation of the results obtained with the Monte Carlo in relation to the eMC algorithm is higher than 3%, taking into account the statistical fluctuation inherent in the system in some case tests. 2019 artículo científico 2319-0612 https://www.redalyc.org/articulo.oa?id=722280831002 en http://www.redalyc.org/revista.oa?id=7222 Brazilian Journal of Radiation Sciences application/pdf Sociedade Brasileira de Proteção Radiológica - SBPR Brazilian Journal of Radiation Sciences (Brasil) Num.1 Vol.7
title Quality control of radiotherapy treatment plans with electrons
topic Biología
EGSnrc
Radiotherapy
Monte Carlo dosimetry
url https://www.redalyc.org/articulo.oa?id=722280831002