Comparative Dosimetric Study in Chest Computed Tomography Using Phantoms

Fuente: Redalyc
Saved in:
Bibliographic Details
Main Author: Wadia Aburjaile
Format: Artículo científico
Language:en
Published: Sociedade Brasileira de Proteção Radiológica - SBPR 2019
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1876458837161017344
author Wadia Aburjaile
author_facet Wadia Aburjaile
contents Comparative Dosimetric Study in Chest Computed Tomography Using Phantoms Wadia Aburjaile Mauricio Gomez G Guedes Arnaldo Prata Mourão Biología phantoms dosimetry Computed Tomography The dissemination of Computed Tomography (CT) scan has promoted a significant increase in the absorbed dose by patients due to the diagnosis. Therefore, it is indispensable to improve protocols, seeking smaller doses, without impairing the diagnostic quality of the image. The risks of stochastic effects are greater for children due to tissue radiosensitivity coupled with longer life expectancy. In this work, a cylindrical phantom made of polymethylmethacrylate was used representing an adult chest, and a second phantom made of the same material was designed in an oblong shape, including axillary region, based on the dimensions of an eight-year-old pediatric patient. A comparative study was performed between chest scans formulated in two CT scanners in different radiodiagnostic services. The central slice of the both phantoms was irradiated successively, using a pencil ionization chamber, for the measurements in five different spots of each phantom. From the measurements, we obtained values of weighted and volumetric Dose Index (Cvol). The scans were performed with the routine chest acquisition protocols of the radiodiagnostic services, both for a voltage of 120 kV X-ray tube supply voltage. This work allowed to compare the dose between patients with variable chest volumes and the dose variation in patients between two CT scanners used for image generation with the same diagnostic objective. 2019 artículo científico 2319-0612 https://www.redalyc.org/articulo.oa?id=722280832005 en http://www.redalyc.org/revista.oa?id=7222 Brazilian Journal of Radiation Sciences application/pdf Sociedade Brasileira de Proteção Radiológica - SBPR Brazilian Journal of Radiation Sciences (Brasil) Num.1A Vol.7
format Artículo científico
id redalyc_722280832005
institution Redalyc
language en
publishDate 2019
publisher Sociedade Brasileira de Proteção Radiológica - SBPR
spellingShingle Comparative Dosimetric Study in Chest Computed Tomography Using Phantoms
Wadia Aburjaile
Biología
phantoms
dosimetry
Computed Tomography
Comparative Dosimetric Study in Chest Computed Tomography Using Phantoms Wadia Aburjaile Mauricio Gomez G Guedes Arnaldo Prata Mourão Biología phantoms dosimetry Computed Tomography The dissemination of Computed Tomography (CT) scan has promoted a significant increase in the absorbed dose by patients due to the diagnosis. Therefore, it is indispensable to improve protocols, seeking smaller doses, without impairing the diagnostic quality of the image. The risks of stochastic effects are greater for children due to tissue radiosensitivity coupled with longer life expectancy. In this work, a cylindrical phantom made of polymethylmethacrylate was used representing an adult chest, and a second phantom made of the same material was designed in an oblong shape, including axillary region, based on the dimensions of an eight-year-old pediatric patient. A comparative study was performed between chest scans formulated in two CT scanners in different radiodiagnostic services. The central slice of the both phantoms was irradiated successively, using a pencil ionization chamber, for the measurements in five different spots of each phantom. From the measurements, we obtained values of weighted and volumetric Dose Index (Cvol). The scans were performed with the routine chest acquisition protocols of the radiodiagnostic services, both for a voltage of 120 kV X-ray tube supply voltage. This work allowed to compare the dose between patients with variable chest volumes and the dose variation in patients between two CT scanners used for image generation with the same diagnostic objective. 2019 artículo científico 2319-0612 https://www.redalyc.org/articulo.oa?id=722280832005 en http://www.redalyc.org/revista.oa?id=7222 Brazilian Journal of Radiation Sciences application/pdf Sociedade Brasileira de Proteção Radiológica - SBPR Brazilian Journal of Radiation Sciences (Brasil) Num.1A Vol.7
title Comparative Dosimetric Study in Chest Computed Tomography Using Phantoms
topic Biología
phantoms
dosimetry
Computed Tomography
url https://www.redalyc.org/articulo.oa?id=722280832005