Verification of angular dependence in MOSFET detector

Fuente: Redalyc
Enregistré dans:
Détails bibliographiques
Auteur principal: Clayton Henrique Souza
Format: Artículo científico
Langue:en
Publié: Sociedade Brasileira de Proteção Radiológica - SBPR 2019
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1876456199149322240
author Clayton Henrique Souza
author_facet Clayton Henrique Souza
contents Verification of angular dependence in MOSFET detector Clayton Henrique Souza J. M. B. Shorto P. T. D. Siqueira M. G. Nunes I. A. Silva Jr H. Yoriyaz Biología MOSFET reproducibility angular dependence In vivo dosimetry is an essential tool for quality assurance programs, being a procedure commonly performed with thermoluminescent dosimeters (TLDs) or diodes. However, a type of dosimeter that has increasing popularity in recent years is the metal-oxide-semiconductor field effect transistor (MOSFET) detector. MOSFET dosimeters fulfill all the necessary characteristics to realize in vivo dosimetry since it has a small size, good precision and feasibility of measurement, as well as easy handling. Nevertheless, its true differential is to allow reading of dose in real time, enabling immediate intervention in the correction of physical parameters deviations and anticipation of small anatomical changes in the patient during treatment. In order for MOSFET dosimeter to be better accepted in clinical routine, information reporting performance should be available frequently. For this reason, this work proposes to verify reproducibility and angular dependence of a standard sensitivity MOSFET dosimeter (TN-502RD-H) for Cs-137 and Co-60 sources. Experimental data were satisfactory and MOSFET dosimeter presented a reproducibility of 3.3% and 2.7% (±1 SD) for Cs137 and Co-60 sources, respectively. In addition, an angular dependence of up to 6.1% and 16.3% for both radioactive sources, respectively. It is conclusive that MOSFET dosimeter TN-502RD-H has satisfactory reproducibility and a considerable angular dependence, mainly for the Co-60 source. This means that although precise measurements, special attention must be taken for applications in certain anatomical regions in a patient. 2019 artículo científico 2319-0612 https://www.redalyc.org/articulo.oa?id=722280838022 en http://www.redalyc.org/revista.oa?id=7222 Brazilian Journal of Radiation Sciences application/pdf Sociedade Brasileira de Proteção Radiológica - SBPR Brazilian Journal of Radiation Sciences (Brasil) Num.2A Vol.7
format Artículo científico
id redalyc_722280838022
institution Redalyc
language en
publishDate 2019
publisher Sociedade Brasileira de Proteção Radiológica - SBPR
spellingShingle Verification of angular dependence in MOSFET detector
Clayton Henrique Souza
Biología
MOSFET
reproducibility
angular dependence
Verification of angular dependence in MOSFET detector Clayton Henrique Souza J. M. B. Shorto P. T. D. Siqueira M. G. Nunes I. A. Silva Jr H. Yoriyaz Biología MOSFET reproducibility angular dependence In vivo dosimetry is an essential tool for quality assurance programs, being a procedure commonly performed with thermoluminescent dosimeters (TLDs) or diodes. However, a type of dosimeter that has increasing popularity in recent years is the metal-oxide-semiconductor field effect transistor (MOSFET) detector. MOSFET dosimeters fulfill all the necessary characteristics to realize in vivo dosimetry since it has a small size, good precision and feasibility of measurement, as well as easy handling. Nevertheless, its true differential is to allow reading of dose in real time, enabling immediate intervention in the correction of physical parameters deviations and anticipation of small anatomical changes in the patient during treatment. In order for MOSFET dosimeter to be better accepted in clinical routine, information reporting performance should be available frequently. For this reason, this work proposes to verify reproducibility and angular dependence of a standard sensitivity MOSFET dosimeter (TN-502RD-H) for Cs-137 and Co-60 sources. Experimental data were satisfactory and MOSFET dosimeter presented a reproducibility of 3.3% and 2.7% (±1 SD) for Cs137 and Co-60 sources, respectively. In addition, an angular dependence of up to 6.1% and 16.3% for both radioactive sources, respectively. It is conclusive that MOSFET dosimeter TN-502RD-H has satisfactory reproducibility and a considerable angular dependence, mainly for the Co-60 source. This means that although precise measurements, special attention must be taken for applications in certain anatomical regions in a patient. 2019 artículo científico 2319-0612 https://www.redalyc.org/articulo.oa?id=722280838022 en http://www.redalyc.org/revista.oa?id=7222 Brazilian Journal of Radiation Sciences application/pdf Sociedade Brasileira de Proteção Radiológica - SBPR Brazilian Journal of Radiation Sciences (Brasil) Num.2A Vol.7
title Verification of angular dependence in MOSFET detector
topic Biología
MOSFET
reproducibility
angular dependence
url https://www.redalyc.org/articulo.oa?id=722280838022