Feasibility studies of using thin entrance window photodiodes for clinical electron beam dosimetry

Fuente: Redalyc
Guardado en:
Detalles Bibliográficos
Autor principal: Cristina R. Nascimento
Formato: Artículo científico
Lenguaje:en
Publicado: Sociedade Brasileira de Proteção Radiológica - SBPR 2019
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1876437506697723904
author Cristina R. Nascimento
author_facet Cristina R. Nascimento
contents Feasibility studies of using thin entrance window photodiodes for clinical electron beam dosimetry Cristina R. Nascimento Viviane K. Asfora Vinicius R. M. Barros Josemary A. C. Gonçalves Luiza F. R. Andrade Helen J. Khoury Carmen C. Bueno Biología Solid state dosimetry Electron dosimetry Si photodiodes dosimeters The response of the commercial XRA-24 PIN photodiode (5.76 mm2 active area) for clinical electron beam dosimetry covering the range of 8-12 MeV was investigated. Within this energy range, the charge generated in the diode’s sensitive volume is linearly dependent on the absorbed dose up to 320 cGy. However, charge sensitivity coefficients evidenced that the dose response of the diode is slightly dependent on the electron beam energy. Indeed, the diode’s energy dependence was within 8.5% for 8-12 MeV electron beams. On the other hand, it was also observed an excellent repeatability of these results with a variation coefficient (VC) lower than 0.4%, which is within the 1% tolerance limit recommended by the AAPM TG-62. Furthermore, the agreement between the percentage depth dose profiles (PDD) gathered with the diode and the ionization chamber allowed achieving the electron beam quality within 1% of that obtained with the ionization chamber. Based on these results, the photodiode XRA-24 can be a reliable and inexpensive alternative for electron beams dosimetry. 2019 artículo científico 2319-0612 https://www.redalyc.org/articulo.oa?id=722280838048 en http://www.redalyc.org/revista.oa?id=7222 Brazilian Journal of Radiation Sciences application/pdf Sociedade Brasileira de Proteção Radiológica - SBPR Brazilian Journal of Radiation Sciences (Brasil) Num.2A Vol.7
format Artículo científico
id redalyc_722280838048
institution Redalyc
language en
publishDate 2019
publisher Sociedade Brasileira de Proteção Radiológica - SBPR
spellingShingle Feasibility studies of using thin entrance window photodiodes for clinical electron beam dosimetry
Cristina R. Nascimento
Biología
Solid
state dosimetry
Electron dosimetry
Si photodiodes dosimeters
Feasibility studies of using thin entrance window photodiodes for clinical electron beam dosimetry Cristina R. Nascimento Viviane K. Asfora Vinicius R. M. Barros Josemary A. C. Gonçalves Luiza F. R. Andrade Helen J. Khoury Carmen C. Bueno Biología Solid state dosimetry Electron dosimetry Si photodiodes dosimeters The response of the commercial XRA-24 PIN photodiode (5.76 mm2 active area) for clinical electron beam dosimetry covering the range of 8-12 MeV was investigated. Within this energy range, the charge generated in the diode’s sensitive volume is linearly dependent on the absorbed dose up to 320 cGy. However, charge sensitivity coefficients evidenced that the dose response of the diode is slightly dependent on the electron beam energy. Indeed, the diode’s energy dependence was within 8.5% for 8-12 MeV electron beams. On the other hand, it was also observed an excellent repeatability of these results with a variation coefficient (VC) lower than 0.4%, which is within the 1% tolerance limit recommended by the AAPM TG-62. Furthermore, the agreement between the percentage depth dose profiles (PDD) gathered with the diode and the ionization chamber allowed achieving the electron beam quality within 1% of that obtained with the ionization chamber. Based on these results, the photodiode XRA-24 can be a reliable and inexpensive alternative for electron beams dosimetry. 2019 artículo científico 2319-0612 https://www.redalyc.org/articulo.oa?id=722280838048 en http://www.redalyc.org/revista.oa?id=7222 Brazilian Journal of Radiation Sciences application/pdf Sociedade Brasileira de Proteção Radiológica - SBPR Brazilian Journal of Radiation Sciences (Brasil) Num.2A Vol.7
title Feasibility studies of using thin entrance window photodiodes for clinical electron beam dosimetry
topic Biología
Solid
state dosimetry
Electron dosimetry
Si photodiodes dosimeters
url https://www.redalyc.org/articulo.oa?id=722280838048