Image quality assessment using NEMA NU 4/2008 standards in small animal PET scanner

Fuente: Redalyc
Enregistré dans:
Détails bibliographiques
Auteur principal: Rodrigo Modesto Gadelha Gontijo
Format: Artículo científico
Langue:en
Publié: Sociedade Brasileira de Proteção Radiológica - SBPR 2019
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1876430431440601088
author Rodrigo Modesto Gadelha Gontijo
author_facet Rodrigo Modesto Gadelha Gontijo
contents Image quality assessment using NEMA NU 4/2008 standards in small animal PET scanner Rodrigo Modesto Gadelha Gontijo Andréa Vidal Ferreira Juliana Batista Silva Marcelo Henrique Mamede Biología NEMA Image Quality Positron Emission Tomography In Brazil, there are few microPET in use and a quality control protocols standardization are needed to harmonize their use in the research field. Thus, the purpose of this study is to characterize the image quality performance of the microPET scanner (LabPET 4, GE healthcare Technologies, Waukesha, WI) using the NEMA NU 4/ 2008 standards and specific phantom. The NEMA image-quality (IQ) phantom consists of 3 different regions to analyze distinct characteristics: image noise (%SD), expressed as percentage SD in a uniform region (%SD), recovery coefficient (RC) and Spill-over (SOR) in air and water. The IQ phantom was filled with 18F-FDG calibrated at the beginning of acquisition, placed in the center of the field-of-view (FOV) and measured with the typical whole body imaging protocol. The images were reconstructed with different reconstruction methods (FBP-2D; MLEM-3D and OSEM-3D); with and without high resolution (HR) when possible. The results were compared. The LabPET 4 system produces appropriate image and with performance according to the literature. The present study is an initial step to verify the NEMA NU 4/2008 use in the Brazilian scenario for further standardization. 2019 artículo científico 2319-0612 https://www.redalyc.org/articulo.oa?id=722280838050 en http://www.redalyc.org/revista.oa?id=7222 Brazilian Journal of Radiation Sciences application/pdf Sociedade Brasileira de Proteção Radiológica - SBPR Brazilian Journal of Radiation Sciences (Brasil) Num.2A Vol.7
format Artículo científico
id redalyc_722280838050
institution Redalyc
language en
publishDate 2019
publisher Sociedade Brasileira de Proteção Radiológica - SBPR
spellingShingle Image quality assessment using NEMA NU 4/2008 standards in small animal PET scanner
Rodrigo Modesto Gadelha Gontijo
Biología
NEMA
Image Quality
Positron Emission Tomography
Image quality assessment using NEMA NU 4/2008 standards in small animal PET scanner Rodrigo Modesto Gadelha Gontijo Andréa Vidal Ferreira Juliana Batista Silva Marcelo Henrique Mamede Biología NEMA Image Quality Positron Emission Tomography In Brazil, there are few microPET in use and a quality control protocols standardization are needed to harmonize their use in the research field. Thus, the purpose of this study is to characterize the image quality performance of the microPET scanner (LabPET 4, GE healthcare Technologies, Waukesha, WI) using the NEMA NU 4/ 2008 standards and specific phantom. The NEMA image-quality (IQ) phantom consists of 3 different regions to analyze distinct characteristics: image noise (%SD), expressed as percentage SD in a uniform region (%SD), recovery coefficient (RC) and Spill-over (SOR) in air and water. The IQ phantom was filled with 18F-FDG calibrated at the beginning of acquisition, placed in the center of the field-of-view (FOV) and measured with the typical whole body imaging protocol. The images were reconstructed with different reconstruction methods (FBP-2D; MLEM-3D and OSEM-3D); with and without high resolution (HR) when possible. The results were compared. The LabPET 4 system produces appropriate image and with performance according to the literature. The present study is an initial step to verify the NEMA NU 4/2008 use in the Brazilian scenario for further standardization. 2019 artículo científico 2319-0612 https://www.redalyc.org/articulo.oa?id=722280838050 en http://www.redalyc.org/revista.oa?id=7222 Brazilian Journal of Radiation Sciences application/pdf Sociedade Brasileira de Proteção Radiológica - SBPR Brazilian Journal of Radiation Sciences (Brasil) Num.2A Vol.7
title Image quality assessment using NEMA NU 4/2008 standards in small animal PET scanner
topic Biología
NEMA
Image Quality
Positron Emission Tomography
url https://www.redalyc.org/articulo.oa?id=722280838050