Application of bias correction methods to improve U3Si2 sample preparation for quantitative analysis by WDXRF

Fuente: Redalyc
Saved in:
Bibliographic Details
Main Author: Marcos Antonio Scapin
Format: Artículo científico
Language:en
Published: Sociedade Brasileira de Proteção Radiológica - SBPR 2019
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1876439839286493184
author Marcos Antonio Scapin
author_facet Marcos Antonio Scapin
contents Application of bias correction methods to improve U3Si2 sample preparation for quantitative analysis by WDXRF Marcos Antonio Scapin S. N. Guilhen L. C. Azevedo M. E. B. Cotrin M. A. F. Pires Biología XRF U3Si2 WDXRF The determination of silicon (Si), total uranium (U) and impurities in uranium-silicide (U3Si2) samples by wavelength dispersion X-ray fluorescence technique (WDXRF) has been already validated and is currently implemented at IPEN’s X-Ray Fluorescence Laboratory (IPEN-CNEN/SP) in São Paulo, Brazil. Sample preparation requires the use of approximately 3 g of H3BO3 as sample holder and 1.8 g of U3Si2. However, because boron is a neutron absorber, this procedure precludes the recovery of U3Si2 from the samples, preventing its use as nuclear fuel. Consequently, a significant amount of uranium is wasted in this process. An estimated average of 15 samples per month is expected to be analyzed by WDXRF, resulting in approx. 320 g of U3Si2 that wouldn’t return to the nuclear fuel cycle. The purpose of this paper is to present a new preparation method, replacing H3BO3 by cellulose acetate {[C6H7O2(OH)3-m(OOCCH3)m], m = 0~3}, thus enabling the recovery of the boron-free U3Si2 from the samples. The results demonstrate that the suggested sample preparation approach is statistically satisfactory, allowing the optimization of the procedure. 2019 artículo científico 2319-0612 https://www.redalyc.org/articulo.oa?id=722280838052 en http://www.redalyc.org/revista.oa?id=7222 Brazilian Journal of Radiation Sciences application/pdf Sociedade Brasileira de Proteção Radiológica - SBPR Brazilian Journal of Radiation Sciences (Brasil) Num.2A Vol.7
format Artículo científico
id redalyc_722280838052
institution Redalyc
language en
publishDate 2019
publisher Sociedade Brasileira de Proteção Radiológica - SBPR
spellingShingle Application of bias correction methods to improve U3Si2 sample preparation for quantitative analysis by WDXRF
Marcos Antonio Scapin
Biología
XRF
U3Si2
WDXRF
Application of bias correction methods to improve U3Si2 sample preparation for quantitative analysis by WDXRF Marcos Antonio Scapin S. N. Guilhen L. C. Azevedo M. E. B. Cotrin M. A. F. Pires Biología XRF U3Si2 WDXRF The determination of silicon (Si), total uranium (U) and impurities in uranium-silicide (U3Si2) samples by wavelength dispersion X-ray fluorescence technique (WDXRF) has been already validated and is currently implemented at IPEN’s X-Ray Fluorescence Laboratory (IPEN-CNEN/SP) in São Paulo, Brazil. Sample preparation requires the use of approximately 3 g of H3BO3 as sample holder and 1.8 g of U3Si2. However, because boron is a neutron absorber, this procedure precludes the recovery of U3Si2 from the samples, preventing its use as nuclear fuel. Consequently, a significant amount of uranium is wasted in this process. An estimated average of 15 samples per month is expected to be analyzed by WDXRF, resulting in approx. 320 g of U3Si2 that wouldn’t return to the nuclear fuel cycle. The purpose of this paper is to present a new preparation method, replacing H3BO3 by cellulose acetate {[C6H7O2(OH)3-m(OOCCH3)m], m = 0~3}, thus enabling the recovery of the boron-free U3Si2 from the samples. The results demonstrate that the suggested sample preparation approach is statistically satisfactory, allowing the optimization of the procedure. 2019 artículo científico 2319-0612 https://www.redalyc.org/articulo.oa?id=722280838052 en http://www.redalyc.org/revista.oa?id=7222 Brazilian Journal of Radiation Sciences application/pdf Sociedade Brasileira de Proteção Radiológica - SBPR Brazilian Journal of Radiation Sciences (Brasil) Num.2A Vol.7
title Application of bias correction methods to improve U3Si2 sample preparation for quantitative analysis by WDXRF
topic Biología
XRF
U3Si2
WDXRF
url https://www.redalyc.org/articulo.oa?id=722280838052