Development of a method for multielemental determination in water by EDXRF with radioisotopic source of 238Pu

Fuente: Redalyc
Saved in:
Bibliographic Details
Main Author: Camilo Fuentes Serrano
Format: Artículo científico
Language:en
Published: Sociedade Brasileira de Proteção Radiológica - SBPR 2019
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1876446788694573056
author Camilo Fuentes Serrano
author_facet Camilo Fuentes Serrano
contents Development of a method for multielemental determination in water by EDXRF with radioisotopic source of 238Pu Camilo Fuentes Serrano Juan Reinaldo Estévez Alfredo Montero Ivan Pupo Zahily Herrero Dennys Leyva Piet Van Espen Jossue Arteche Lino Varcárcel Jose Araujo dos Santos Júnior Biología EDXRF water Multielemental determination A method for determination of Cr, Fe, Co, Ni, Cu, Zn, Hg and Pb in waters by Energy Dispersive X Ray Fluorescence (EDXRF) was implemented, using a radioisotopic source of 238Pu. For previous concentration was employed a procedure including a coprecipitation step with ammonium pyrrolidinedithiocarbamate (APDC) as quelant agent, the separation of the phases by filtration, the measurement of filter by EDXRF and quantification by a thin layer absolute method. Sensitivity curves for K and L lines were obtained respectively. The sensitivity for most elements was greater by an order of magnitude in the case of measurement with a source of 238Pu instead of 109Cd, which means a considerable decrease in measurement times. The influence of the concentration in the precipitation efficiency was evaluated for each element. In all cases the recoveries are close to 100%, for this reason it can be affirmed that the method of determination of the studied elements is quantitative. Metrological parameters of the method such as trueness, precision, detection limit and uncertainty were calculated. A procedure to calculate the uncertainty of the method was elaborated; the most significant source of uncertainty for the thin layer EDXRF method is associated with the determination of instrumental sensitivities. The error associated with the determination, expressed as expanded uncertainty (in %), varied from 15.4% for low element concentrations (2.5-5 μg/L) to 5.4% for the higher concentration range (20-25 μg/L). 2019 artículo científico 2319-0612 https://www.redalyc.org/articulo.oa?id=722280838071 en http://www.redalyc.org/revista.oa?id=7222 Brazilian Journal of Radiation Sciences application/pdf Sociedade Brasileira de Proteção Radiológica - SBPR Brazilian Journal of Radiation Sciences (Brasil) Num.2A Vol.7
format Artículo científico
id redalyc_722280838071
institution Redalyc
language en
publishDate 2019
publisher Sociedade Brasileira de Proteção Radiológica - SBPR
spellingShingle Development of a method for multielemental determination in water by EDXRF with radioisotopic source of 238Pu
Camilo Fuentes Serrano
Biología
EDXRF
water
Multielemental determination
Development of a method for multielemental determination in water by EDXRF with radioisotopic source of 238Pu Camilo Fuentes Serrano Juan Reinaldo Estévez Alfredo Montero Ivan Pupo Zahily Herrero Dennys Leyva Piet Van Espen Jossue Arteche Lino Varcárcel Jose Araujo dos Santos Júnior Biología EDXRF water Multielemental determination A method for determination of Cr, Fe, Co, Ni, Cu, Zn, Hg and Pb in waters by Energy Dispersive X Ray Fluorescence (EDXRF) was implemented, using a radioisotopic source of 238Pu. For previous concentration was employed a procedure including a coprecipitation step with ammonium pyrrolidinedithiocarbamate (APDC) as quelant agent, the separation of the phases by filtration, the measurement of filter by EDXRF and quantification by a thin layer absolute method. Sensitivity curves for K and L lines were obtained respectively. The sensitivity for most elements was greater by an order of magnitude in the case of measurement with a source of 238Pu instead of 109Cd, which means a considerable decrease in measurement times. The influence of the concentration in the precipitation efficiency was evaluated for each element. In all cases the recoveries are close to 100%, for this reason it can be affirmed that the method of determination of the studied elements is quantitative. Metrological parameters of the method such as trueness, precision, detection limit and uncertainty were calculated. A procedure to calculate the uncertainty of the method was elaborated; the most significant source of uncertainty for the thin layer EDXRF method is associated with the determination of instrumental sensitivities. The error associated with the determination, expressed as expanded uncertainty (in %), varied from 15.4% for low element concentrations (2.5-5 μg/L) to 5.4% for the higher concentration range (20-25 μg/L). 2019 artículo científico 2319-0612 https://www.redalyc.org/articulo.oa?id=722280838071 en http://www.redalyc.org/revista.oa?id=7222 Brazilian Journal of Radiation Sciences application/pdf Sociedade Brasileira de Proteção Radiológica - SBPR Brazilian Journal of Radiation Sciences (Brasil) Num.2A Vol.7
title Development of a method for multielemental determination in water by EDXRF with radioisotopic source of 238Pu
topic Biología
EDXRF
water
Multielemental determination
url https://www.redalyc.org/articulo.oa?id=722280838071