Sum-peak method with two NaI(Tl) crystals: 68(Ge + Ga) standardization

Fuente: Redalyc
Enregistré dans:
Détails bibliographiques
Auteur principal: E. M. Oliveira
Format: Artículo científico
Langue:en
Publié: Sociedade Brasileira de Proteção Radiológica - SBPR 2019
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1876468740992794624
author E. M. Oliveira
author_facet E. M. Oliveira
contents Sum-peak method with two NaI(Tl) crystals: 68(Ge + Ga) standardization E. M. Oliveira A. Iwahara R. Poledna C. J. Silva P. A. L. da Cruz R. S. Gomes J. U. Delgado R. T. Lopes Biología sum 68Ge 68Ga peak method anticoincidence method A 68(Ge + Ga) commercial solution has been standardized in LNMRI in Brazil, by sum-peak method, in which a 3”x3” NaI(Tl) gamma-ray detector is positioned at the top of a well-type 5”x5” NaI(Tl) gamma-ray detector, resulting in a set up approximately 4π geometry. In this work the known germanium volatility was tested using three dried sources and three liquid sources in the sum-peak method measurements and the activity results showed a standard deviation of 0.41%. The activities were compared with another primary method: 4πβ−γ livetimed anti-coincidence counting. The two methods gave activity concentration values with differences from the certified value of +0.8 % (anticoincidence method) and -3.4% (sum-peak method). 2019 artículo científico 2319-0612 https://www.redalyc.org/articulo.oa?id=722280901001 en http://www.redalyc.org/revista.oa?id=7222 Brazilian Journal of Radiation Sciences application/pdf Sociedade Brasileira de Proteção Radiológica - SBPR Brazilian Journal of Radiation Sciences (Brasil) Num.3B Vol.7
format Artículo científico
id redalyc_722280901001
institution Redalyc
language en
publishDate 2019
publisher Sociedade Brasileira de Proteção Radiológica - SBPR
spellingShingle Sum-peak method with two NaI(Tl) crystals: 68(Ge + Ga) standardization
E. M. Oliveira
Biología
sum
68Ge
68Ga
peak method
anticoincidence method
Sum-peak method with two NaI(Tl) crystals: 68(Ge + Ga) standardization E. M. Oliveira A. Iwahara R. Poledna C. J. Silva P. A. L. da Cruz R. S. Gomes J. U. Delgado R. T. Lopes Biología sum 68Ge 68Ga peak method anticoincidence method A 68(Ge + Ga) commercial solution has been standardized in LNMRI in Brazil, by sum-peak method, in which a 3”x3” NaI(Tl) gamma-ray detector is positioned at the top of a well-type 5”x5” NaI(Tl) gamma-ray detector, resulting in a set up approximately 4π geometry. In this work the known germanium volatility was tested using three dried sources and three liquid sources in the sum-peak method measurements and the activity results showed a standard deviation of 0.41%. The activities were compared with another primary method: 4πβ−γ livetimed anti-coincidence counting. The two methods gave activity concentration values with differences from the certified value of +0.8 % (anticoincidence method) and -3.4% (sum-peak method). 2019 artículo científico 2319-0612 https://www.redalyc.org/articulo.oa?id=722280901001 en http://www.redalyc.org/revista.oa?id=7222 Brazilian Journal of Radiation Sciences application/pdf Sociedade Brasileira de Proteção Radiológica - SBPR Brazilian Journal of Radiation Sciences (Brasil) Num.3B Vol.7
title Sum-peak method with two NaI(Tl) crystals: 68(Ge + Ga) standardization
topic Biología
sum
68Ge
68Ga
peak method
anticoincidence method
url https://www.redalyc.org/articulo.oa?id=722280901001