Determination of fluid dynamic parameters through imports of CFD images validated in experiments for the MCNPX code

Fuente: Redalyc
Saved in:
Bibliographic Details
Main Author: Victor Hugo Farias Ferreira da Silva
Format: Artículo científico
Language:en
Published: Sociedade Brasileira de Proteção Radiológica - SBPR 2020
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1876431034305740800
author Victor Hugo Farias Ferreira da Silva
author_facet Victor Hugo Farias Ferreira da Silva
contents Determination of fluid dynamic parameters through imports of CFD images validated in experiments for the MCNPX code Victor Hugo Farias Ferreira da Silva Carlos Costa Dantas Silvio de Barros Melo Fernando Roberto de Andrade Lima Pamalla Rafaelly Barbosa de Oliveira Tennyson Accetti Resende Filho Jorge Alexandre Gomes Lins Eudes Bertony Vieira Bruno Gomes Andrade Milton Santos Viana Biología MCNPX CT gamma Validation Importing CFD Pilot cold unities Nonintrusive gamma ray transmission measurements provided a significant contribution to flow structure models describing the FCC riser multiphase system. Circulating Fluidized Bed (CFB) in pilot cold unities are well-known facilities for parameters estimation. Two-phase is model approach to the fluid dynamic studies considering steady state in operational conditions. Flow characterization by semi empirical literature equations and CFD simulations are carried out in flow parameter estimation followed by CT gamma ray validation. In this work, the Monte Carlo simulation of gamma ray scan importing CFD experiments brings a wide range for the two-phase flow investigation. Computational methods are developed to interface geometry and dynamic functions describing circulating flow. Software implementation steps convert color scales into image grids corresponding to solid density. Therefore, the two-phase flow in CFD simulations was imported in MCNPX geometry. The Monte Carlo tomography simulation of three riser heights 0,65 m, 1,38 m and 3,42 m, yield volumetric fractions of 0,038, 0,013 and 0,004 for the solid radial distribution. The heights are of the three testing sections for monitoring pressure and gamma intensity. Results are compared to CT gamma ray tomography and to literature data. 2020 artículo científico 2319-0612 https://www.redalyc.org/articulo.oa?id=722280924028 en http://www.redalyc.org/revista.oa?id=7222 Brazilian Journal of Radiation Sciences application/pdf Sociedade Brasileira de Proteção Radiológica - SBPR Brazilian Journal of Radiation Sciences (Brasil) Num.3A Vol.8
format Artículo científico
id redalyc_722280924028
institution Redalyc
language en
publishDate 2020
publisher Sociedade Brasileira de Proteção Radiológica - SBPR
spellingShingle Determination of fluid dynamic parameters through imports of CFD images validated in experiments for the MCNPX code
Victor Hugo Farias Ferreira da Silva
Biología
MCNPX
CT gamma
Validation
Importing CFD
Pilot cold unities
Determination of fluid dynamic parameters through imports of CFD images validated in experiments for the MCNPX code Victor Hugo Farias Ferreira da Silva Carlos Costa Dantas Silvio de Barros Melo Fernando Roberto de Andrade Lima Pamalla Rafaelly Barbosa de Oliveira Tennyson Accetti Resende Filho Jorge Alexandre Gomes Lins Eudes Bertony Vieira Bruno Gomes Andrade Milton Santos Viana Biología MCNPX CT gamma Validation Importing CFD Pilot cold unities Nonintrusive gamma ray transmission measurements provided a significant contribution to flow structure models describing the FCC riser multiphase system. Circulating Fluidized Bed (CFB) in pilot cold unities are well-known facilities for parameters estimation. Two-phase is model approach to the fluid dynamic studies considering steady state in operational conditions. Flow characterization by semi empirical literature equations and CFD simulations are carried out in flow parameter estimation followed by CT gamma ray validation. In this work, the Monte Carlo simulation of gamma ray scan importing CFD experiments brings a wide range for the two-phase flow investigation. Computational methods are developed to interface geometry and dynamic functions describing circulating flow. Software implementation steps convert color scales into image grids corresponding to solid density. Therefore, the two-phase flow in CFD simulations was imported in MCNPX geometry. The Monte Carlo tomography simulation of three riser heights 0,65 m, 1,38 m and 3,42 m, yield volumetric fractions of 0,038, 0,013 and 0,004 for the solid radial distribution. The heights are of the three testing sections for monitoring pressure and gamma intensity. Results are compared to CT gamma ray tomography and to literature data. 2020 artículo científico 2319-0612 https://www.redalyc.org/articulo.oa?id=722280924028 en http://www.redalyc.org/revista.oa?id=7222 Brazilian Journal of Radiation Sciences application/pdf Sociedade Brasileira de Proteção Radiológica - SBPR Brazilian Journal of Radiation Sciences (Brasil) Num.3A Vol.8
title Determination of fluid dynamic parameters through imports of CFD images validated in experiments for the MCNPX code
topic Biología
MCNPX
CT gamma
Validation
Importing CFD
Pilot cold unities
url https://www.redalyc.org/articulo.oa?id=722280924028