Commissioning of the Radiation Monitor Calibration Laboratory (LabCal) of IDQBRN for cesium-137 irradiation system

Fuente: Redalyc
Guardado en:
Detalles Bibliográficos
Autor principal: T. M. S SILVA
Formato: Artículo científico
Lenguaje:en
Publicado: Sociedade Brasileira de Proteção Radiológica - SBPR 2021
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1876440399578398720
author T. M. S SILVA
author_facet T. M. S SILVA
contents Commissioning of the Radiation Monitor Calibration Laboratory (LabCal) of IDQBRN for cesium-137 irradiation system T. M. S SILVA A. S AMORIM M.C.V BALTHAR A. SANTOS A. CURZIO R.C CARDOSO W. V. NUNES Biología Cs 137 DQBRN Calibration Commissioning The provision for the Brazilian Army of equipment that provides reliable and safe measurements, enabling decision-making based on radioprotection parameters, leads to the need to investigate the metrology of the calibration system used in the Radiation Monitor Calibration Laboratory (LabCal) of the Institute of Chemical, Biological, Radiological and Nuclear Defense (IDQBRN). To this end, the commissioning in cesium-137 is of primary importance in this process. In order to check the conformity of the radiator system, in this work, the ambient dose equivalent rate, H * (10) ̇ , was obtained experimentally for several configurations to compare them with the appropriate theoretical concepts. For this, the distance between the source of cesium-137 (36.9 GBq in 01/22/2015) and the ionization chamber was varied from 500 to 3000 mm at 250mm intervals. To obtain lower ambient dose equivalent rates, 15 and 32 mm thick lead attenuators were used. The mathematical model that best fit the experimental values was analyzed. In all cases, the potential function offers better fit, since the coefficients of determination obtained are approximately equal to 1, obeying the Law of the Inverse Square of the Distance, according to theoretical foundation. Moreover, it was evaluated that the relative deviations are below the limits established by the relevant standard. 2021 artículo científico 2319-0612 https://www.redalyc.org/articulo.oa?id=722280970010 en http://www.redalyc.org/revista.oa?id=7222 Brazilian Journal of Radiation Sciences application/pdf Sociedade Brasileira de Proteção Radiológica - SBPR Brazilian Journal of Radiation Sciences (Brasil) Num.3 Vol.9
format Artículo científico
id redalyc_722280970010
institution Redalyc
language en
publishDate 2021
publisher Sociedade Brasileira de Proteção Radiológica - SBPR
spellingShingle Commissioning of the Radiation Monitor Calibration Laboratory (LabCal) of IDQBRN for cesium-137 irradiation system
T. M. S SILVA
Biología
Cs
137
DQBRN
Calibration
Commissioning
Commissioning of the Radiation Monitor Calibration Laboratory (LabCal) of IDQBRN for cesium-137 irradiation system T. M. S SILVA A. S AMORIM M.C.V BALTHAR A. SANTOS A. CURZIO R.C CARDOSO W. V. NUNES Biología Cs 137 DQBRN Calibration Commissioning The provision for the Brazilian Army of equipment that provides reliable and safe measurements, enabling decision-making based on radioprotection parameters, leads to the need to investigate the metrology of the calibration system used in the Radiation Monitor Calibration Laboratory (LabCal) of the Institute of Chemical, Biological, Radiological and Nuclear Defense (IDQBRN). To this end, the commissioning in cesium-137 is of primary importance in this process. In order to check the conformity of the radiator system, in this work, the ambient dose equivalent rate, H * (10) ̇ , was obtained experimentally for several configurations to compare them with the appropriate theoretical concepts. For this, the distance between the source of cesium-137 (36.9 GBq in 01/22/2015) and the ionization chamber was varied from 500 to 3000 mm at 250mm intervals. To obtain lower ambient dose equivalent rates, 15 and 32 mm thick lead attenuators were used. The mathematical model that best fit the experimental values was analyzed. In all cases, the potential function offers better fit, since the coefficients of determination obtained are approximately equal to 1, obeying the Law of the Inverse Square of the Distance, according to theoretical foundation. Moreover, it was evaluated that the relative deviations are below the limits established by the relevant standard. 2021 artículo científico 2319-0612 https://www.redalyc.org/articulo.oa?id=722280970010 en http://www.redalyc.org/revista.oa?id=7222 Brazilian Journal of Radiation Sciences application/pdf Sociedade Brasileira de Proteção Radiológica - SBPR Brazilian Journal of Radiation Sciences (Brasil) Num.3 Vol.9
title Commissioning of the Radiation Monitor Calibration Laboratory (LabCal) of IDQBRN for cesium-137 irradiation system
topic Biología
Cs
137
DQBRN
Calibration
Commissioning
url https://www.redalyc.org/articulo.oa?id=722280970010