Comparison between radiochromic film and Sun nuclear edge diode detector during the commissioning of small field size radiosurgery cones

Fuente: Redalyc
Guardado en:
Detalles Bibliográficos
Autor principal: T.S. Fontana
Formato: Artículo científico
Lenguaje:en
Publicado: Sociedade Brasileira de Proteção Radiológica - SBPR 2022
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1876483859453837312
author T.S. Fontana
author_facet T.S. Fontana
contents Comparison between radiochromic film and Sun nuclear edge diode detector during the commissioning of small field size radiosurgery cones T.S. Fontana K.P. Bueno L.D. Albino E.H. Roesler M.F. Santos V.K. Asfora H.J. Khoury Biología diode Radiosurgery commissioning radiochromic film circular collimators Stereotactic Radiosurgery (SRS) is a procedure that uses ionizing radiation in a single fraction or few fractions to treat intracranial lesions. Usually, for these treatments, small photon fields, formed by circular collimators or micro multileaf collimators are used. The objective of the present work is to compare the measurements of the dose in depth (PDD), the off-axis ratio (OAR), and the output factor (OF) using Edge diode and radiochromic films and analyzing the agreement between the two detectors during these measurements. In the gamma index analysis of the profiles, the minimum percentage reached was 98.3% of the points in the criterion 1% and 0.5 mm. The maximum percentage difference in the output factor was 2.79% for a cone 4 mm and 10FFF. In the gamma index analysis of the PDDs, the minimum percentage reached was 97% of the points in the criterion 1% and 1mm. The results show a good agreement between the edge detector and the film in small field measurements for radiosurgery. 2022 artículo científico 2319-0612 https://www.redalyc.org/articulo.oa?id=722280973017 en http://www.redalyc.org/revista.oa?id=7222 Brazilian Journal of Radiation Sciences application/pdf Sociedade Brasileira de Proteção Radiológica - SBPR Brazilian Journal of Radiation Sciences (Brasil) Num.2A Vol.10
format Artículo científico
id redalyc_722280973017
institution Redalyc
language en
publishDate 2022
publisher Sociedade Brasileira de Proteção Radiológica - SBPR
spellingShingle Comparison between radiochromic film and Sun nuclear edge diode detector during the commissioning of small field size radiosurgery cones
T.S. Fontana
Biología
diode
Radiosurgery
commissioning
radiochromic film
circular collimators
Comparison between radiochromic film and Sun nuclear edge diode detector during the commissioning of small field size radiosurgery cones T.S. Fontana K.P. Bueno L.D. Albino E.H. Roesler M.F. Santos V.K. Asfora H.J. Khoury Biología diode Radiosurgery commissioning radiochromic film circular collimators Stereotactic Radiosurgery (SRS) is a procedure that uses ionizing radiation in a single fraction or few fractions to treat intracranial lesions. Usually, for these treatments, small photon fields, formed by circular collimators or micro multileaf collimators are used. The objective of the present work is to compare the measurements of the dose in depth (PDD), the off-axis ratio (OAR), and the output factor (OF) using Edge diode and radiochromic films and analyzing the agreement between the two detectors during these measurements. In the gamma index analysis of the profiles, the minimum percentage reached was 98.3% of the points in the criterion 1% and 0.5 mm. The maximum percentage difference in the output factor was 2.79% for a cone 4 mm and 10FFF. In the gamma index analysis of the PDDs, the minimum percentage reached was 97% of the points in the criterion 1% and 1mm. The results show a good agreement between the edge detector and the film in small field measurements for radiosurgery. 2022 artículo científico 2319-0612 https://www.redalyc.org/articulo.oa?id=722280973017 en http://www.redalyc.org/revista.oa?id=7222 Brazilian Journal of Radiation Sciences application/pdf Sociedade Brasileira de Proteção Radiológica - SBPR Brazilian Journal of Radiation Sciences (Brasil) Num.2A Vol.10
title Comparison between radiochromic film and Sun nuclear edge diode detector during the commissioning of small field size radiosurgery cones
topic Biología
diode
Radiosurgery
commissioning
radiochromic film
circular collimators
url https://www.redalyc.org/articulo.oa?id=722280973017