Saved in:
| Main Author: | |
|---|---|
| Format: | Artículo científico |
| Language: | en |
| Published: |
Sociedade Brasileira de Proteção Radiológica - SBPR
2022
|
| Subjects: | |
| Online Access: | https://www.redalyc.org/articulo.oa?id=722280973020 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Table of Contents:
- Results of type testing of MTS-N dosimeters with IEC 62387:2012 standard at the laboratory of external dosimetry in Nicaragua A.M. Castillo N.A. Roas Biología requirement type testing Dose response This study presents the results of the performance of the Laboratory of External Dosimetry (LDE) located at the Laboratory of Radiation Physics and Metrology (LAF-RAM), according to the ISO/IEC 62387:2012. The LAFRAM is the only External Dosimetry service provider in Nicaragua. The test is considered a validation of the method for the LDE and the Quality Management System of LAF-RAM. The chosen performance testing according to IEC 62387:2012 are Coefficient of variation, Non linearity, Radiation energy and angle of incidence, Dosimeter drop, Light exposure (reader), Over response of radiation incidence and dose build-up, fading, selfirradiation and natural radiation response. The results in general show that all tests are in compliance with the requirements except for some temporal conditions in dose build-up, fading, self-irradiation test. 2022 artículo científico 2319-0612 https://www.redalyc.org/articulo.oa?id=722280973020 en http://www.redalyc.org/revista.oa?id=7222 Brazilian Journal of Radiation Sciences application/pdf Sociedade Brasileira de Proteção Radiológica - SBPR Brazilian Journal of Radiation Sciences (Brasil) Num.2A Vol.10