Power system stress analysis for main grid substations in Brazil

Fuente: Redalyc
Saved in:
Bibliographic Details
Main Author: Paulo R. Duailibe Monteiro
Format: Artículo científico
Language:en
Published: Universidad de Tarapacá 2016
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1876429976847253504
author Paulo R. Duailibe Monteiro
author_facet Paulo R. Duailibe Monteiro
contents Power system stress analysis for main grid substations in Brazil Paulo R. Duailibe Monteiro Leonardo de C. Rocha Carlos A. P. Soares Wainer S. Silva Ingeniería load flow Overrating substation short circuit insulation coordination The analyses for overcoming problems arising in basic grid substation buses and equipment are of essential importance to the Brazilian electric sector in view of the constant expansion of this system. These analyses are not simple tasks because they involve an evaluation of the impacts caused by installations arising from new connections and because they always include various studies. This paper presents examples of necessary investigations into the causes of the rated characteristic violations of basic grid installation components. An overview of the proposed electrical system that will be evaluated in conjunction with a new thermal generator plant connection to an existing system substation system is presented. 2016 artículo científico 0718-3291 https://www.redalyc.org/articulo.oa?id=77246569003 en http://www.redalyc.org/revista.oa?id=772 Ingeniare. Revista Chilena de Ingeniería application/pdf Universidad de Tarapacá Ingeniare. Revista Chilena de Ingeniería (Chile) Num.3 Vol.24
format Artículo científico
id redalyc_77246569003
institution Redalyc
language en
publishDate 2016
publisher Universidad de Tarapacá
spellingShingle Power system stress analysis for main grid substations in Brazil
Paulo R. Duailibe Monteiro
Ingeniería
load flow
Overrating
substation
short circuit
insulation coordination
Power system stress analysis for main grid substations in Brazil Paulo R. Duailibe Monteiro Leonardo de C. Rocha Carlos A. P. Soares Wainer S. Silva Ingeniería load flow Overrating substation short circuit insulation coordination The analyses for overcoming problems arising in basic grid substation buses and equipment are of essential importance to the Brazilian electric sector in view of the constant expansion of this system. These analyses are not simple tasks because they involve an evaluation of the impacts caused by installations arising from new connections and because they always include various studies. This paper presents examples of necessary investigations into the causes of the rated characteristic violations of basic grid installation components. An overview of the proposed electrical system that will be evaluated in conjunction with a new thermal generator plant connection to an existing system substation system is presented. 2016 artículo científico 0718-3291 https://www.redalyc.org/articulo.oa?id=77246569003 en http://www.redalyc.org/revista.oa?id=772 Ingeniare. Revista Chilena de Ingeniería application/pdf Universidad de Tarapacá Ingeniare. Revista Chilena de Ingeniería (Chile) Num.3 Vol.24
title Power system stress analysis for main grid substations in Brazil
topic Ingeniería
load flow
Overrating
substation
short circuit
insulation coordination
url https://www.redalyc.org/articulo.oa?id=77246569003