Histological artifacts associated with laser and electroscalpel gingivectomy: Case series

Fuente: Redalyc
Saved in:
Bibliographic Details
Main Author: Jennifer Orozco
Format: Artículo científico
Language:en
Published: Instituto Nacional de Salud 2023
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1876456937793519616
author Jennifer Orozco
author_facet Jennifer Orozco
contents Histological artifacts associated with laser and electroscalpel gingivectomy: Case series Jennifer Orozco David Rico Lía Barrios Vivi Hoyos Pilar Blanco Medicina solid state lasers artifacts histology Introduction. Over time, efforts have been invested in the design of new instruments that overcome the disadvantages of the gold standard instrument in surgery, the scalpel. As a result, electronic equipment has emerged such as the electric scalpel and laser devices. The available evidence on these instruments suggests that the tissue response is related to each instrument’s physical and biological cutting principles.Objective. To compare the histological changes in gingiva samples associated with surgical cutting performed with a 940 nm diode laser, a 2780 nm erbium, chromium: yttriumscandium-gallium-garnet (Er,Cr:YSGG) laser, and an electric scalpel, by presenting a series of cases.Case presentation. We present three cases of healthy patients undergoing cosmetic surgery. The clinical examination revealed exposure of a keratinized gingiva band greater than 4 mm, normal color and texture in gingival tissue, with a firm consistency and no bleeding on periodontal probing. Gingivectomy was indicated with the following protocols: Diode laser of 940 nm at 1 W, in continuous mode; Er,Cr:YSGG laser of 2780 nm at 2.5 W, 75 Hz, H mode, air 20, water 40, gold tip MT4); and electric scalpel in cutting mode at power level four. Gingival tissue samples were taken and stored in 10% formaldehyde for histological analysis.Conclusion. All the evaluated cutting instruments generated histological changes produced by the thermal effect, the main ones being collagen coagulation and carbonization. The depth of thermal damage caused by the 2780 nm Er,Cr:YSGG laser was much lesser than that induced by the electric scalpel and the 940 nm diode laser. 2023 otro 0120-4157 https://www.redalyc.org/articulo.oa?id=84376109002 https://www.redalyc.org/journal/843/84376109002/ https://www.redalyc.org/journal/843/84376109002/html/ https://www.redalyc.org/journal/843/84376109002/84376109002.epub https://www.redalyc.org/journal/843/84376109002/movil https://doi.org/10.7705/biomedica.6930 en http://www.redalyc.org/revista.oa?id=843 Biomédica application/pdf Instituto Nacional de Salud Biomédica (Colombia) Num.3 Vol.43
format Artículo científico
id redalyc_84376109002
institution Redalyc
language en
publishDate 2023
publisher Instituto Nacional de Salud
spellingShingle Histological artifacts associated with laser and electroscalpel gingivectomy: Case series
Jennifer Orozco
Medicina
solid
state
lasers
artifacts
histology
Histological artifacts associated with laser and electroscalpel gingivectomy: Case series Jennifer Orozco David Rico Lía Barrios Vivi Hoyos Pilar Blanco Medicina solid state lasers artifacts histology Introduction. Over time, efforts have been invested in the design of new instruments that overcome the disadvantages of the gold standard instrument in surgery, the scalpel. As a result, electronic equipment has emerged such as the electric scalpel and laser devices. The available evidence on these instruments suggests that the tissue response is related to each instrument’s physical and biological cutting principles.Objective. To compare the histological changes in gingiva samples associated with surgical cutting performed with a 940 nm diode laser, a 2780 nm erbium, chromium: yttriumscandium-gallium-garnet (Er,Cr:YSGG) laser, and an electric scalpel, by presenting a series of cases.Case presentation. We present three cases of healthy patients undergoing cosmetic surgery. The clinical examination revealed exposure of a keratinized gingiva band greater than 4 mm, normal color and texture in gingival tissue, with a firm consistency and no bleeding on periodontal probing. Gingivectomy was indicated with the following protocols: Diode laser of 940 nm at 1 W, in continuous mode; Er,Cr:YSGG laser of 2780 nm at 2.5 W, 75 Hz, H mode, air 20, water 40, gold tip MT4); and electric scalpel in cutting mode at power level four. Gingival tissue samples were taken and stored in 10% formaldehyde for histological analysis.Conclusion. All the evaluated cutting instruments generated histological changes produced by the thermal effect, the main ones being collagen coagulation and carbonization. The depth of thermal damage caused by the 2780 nm Er,Cr:YSGG laser was much lesser than that induced by the electric scalpel and the 940 nm diode laser. 2023 otro 0120-4157 https://www.redalyc.org/articulo.oa?id=84376109002 https://www.redalyc.org/journal/843/84376109002/ https://www.redalyc.org/journal/843/84376109002/html/ https://www.redalyc.org/journal/843/84376109002/84376109002.epub https://www.redalyc.org/journal/843/84376109002/movil https://doi.org/10.7705/biomedica.6930 en http://www.redalyc.org/revista.oa?id=843 Biomédica application/pdf Instituto Nacional de Salud Biomédica (Colombia) Num.3 Vol.43
title Histological artifacts associated with laser and electroscalpel gingivectomy: Case series
topic Medicina
solid
state
lasers
artifacts
histology
url https://www.redalyc.org/articulo.oa?id=84376109002
https://www.redalyc.org/journal/843/84376109002/
https://www.redalyc.org/journal/843/84376109002/html/
https://www.redalyc.org/journal/843/84376109002/84376109002.epub
https://www.redalyc.org/journal/843/84376109002/movil
https://doi.org/10.7705/biomedica.6930