Calibration and volunteer testing of a prototype contactless respiratory motion detection system based on laser tracking

Fuente: Wiley Open Access
Saved in:
Bibliographic Details
Main Authors: Isnaini Nur Islami, Amar Ma'ruf Irfan Muhamadi, Wahyu Edy Wibowo, Aloysius Mario Yudi Putranto, Arief Sudarmaji, Fielda Djuita, Supriyanto Ardjo Pawiro
Format: Artículo Open Access
Published: Wiley 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867007316590592000
author Isnaini Nur Islami
Amar Ma'ruf Irfan Muhamadi
Wahyu Edy Wibowo
Aloysius Mario Yudi Putranto
Arief Sudarmaji
Fielda Djuita
Supriyanto Ardjo Pawiro
author_facet Isnaini Nur Islami
Amar Ma'ruf Irfan Muhamadi
Wahyu Edy Wibowo
Aloysius Mario Yudi Putranto
Arief Sudarmaji
Fielda Djuita
Supriyanto Ardjo Pawiro
Isnaini Nur Islami
Amar Ma'ruf Irfan Muhamadi
Wahyu Edy Wibowo
Aloysius Mario Yudi Putranto
Arief Sudarmaji
Fielda Djuita
Supriyanto Ardjo Pawiro
collection Wiley Open Access
contents Calibration and volunteer testing of a prototype contactless respiratory motion detection system based on laser tracking Isnaini Nur Islami Amar Ma'ruf Irfan Muhamadi Wahyu Edy Wibowo Aloysius Mario Yudi Putranto Arief Sudarmaji Fielda Djuita Supriyanto Ardjo Pawiro Journal of Applied Clinical Medical Physics AbstractPurposeThe goal of this study was to assess the feasibility of a cost‐effective prototype of a laser‐based respiratory motion detection system utilizing a Leuze LDS for breath monitoring through calibration and volunteer tests.MethodsThis study was performed using the Anzai AZ‐773 V and computerized imaging reference systems (CIRS) motion phantoms for calibration tests. The calibration of the laser‐based respiratory motion detection system involved spatial accuracy testing, amplitude calibration, and temporal accuracy. Volunteer testing was conducted on eight volunteers at the inferior end of the sternum and the abdomen area. The accuracy of the data recorded by the laser‐based respiratory motion detection system was validated against established clinical reference tracking systems namely real‐time position management (RPM) and Anzai AZ‐733 V system.ResultsCalibration with an Anzai AZ‐773 V and CIRS phantoms demonstrated an average error of 1.17% ± 0.64% and an average amplitude calibration correlation coefficient of 0.975 ± 0.004. Volunteer tests, compared to the Anzai AZ‐733 V clinical system and RPM system, revealed average correlation coefficients for deep inspiration breath‐hold are 0.931 ± 0.02 and 0.936 ± 0.03, respectively, and for free breathing are 0.85 ± 0.07 and 0.77 ± 0.1, respectively.ConclusionsOverall, the data suggest that the in‐house laser‐based respiratory motion detection system performed well, with an error percentage below 10%. A reasonably good correlation coefficient was obtained, indicating that the readings obtained from the laser system are consistent with those set on the phantom and clinical respiratory motion detection systems. Although promising through the calibration process and volunteer tests, further studies are required to generate trigger data linked directly to computerized tomography and linear accelerator facilities, thereby advancing the clinical viability of this innovative laser‐based respiratory motion detection system. 10.1002/acm2.14607 http://creativecommons.org/licenses/by/4.0/
doi_str_mv 10.1002/acm2.14607
format Artículo Open Access
id wiley_oa_10_1002_acm2_14607
institution Wiley Open Access
license_str_mv http://creativecommons.org/licenses/by/4.0/
publishDate 2024
publisher Wiley
record_format wiley_oa
spellingShingle Calibration and volunteer testing of a prototype contactless respiratory motion detection system based on laser tracking
Isnaini Nur Islami
Amar Ma'ruf Irfan Muhamadi
Wahyu Edy Wibowo
Aloysius Mario Yudi Putranto
Arief Sudarmaji
Fielda Djuita
Supriyanto Ardjo Pawiro
Journal of Applied Clinical Medical Physics
Calibration and volunteer testing of a prototype contactless respiratory motion detection system based on laser tracking Isnaini Nur Islami Amar Ma'ruf Irfan Muhamadi Wahyu Edy Wibowo Aloysius Mario Yudi Putranto Arief Sudarmaji Fielda Djuita Supriyanto Ardjo Pawiro Journal of Applied Clinical Medical Physics AbstractPurposeThe goal of this study was to assess the feasibility of a cost‐effective prototype of a laser‐based respiratory motion detection system utilizing a Leuze LDS for breath monitoring through calibration and volunteer tests.MethodsThis study was performed using the Anzai AZ‐773 V and computerized imaging reference systems (CIRS) motion phantoms for calibration tests. The calibration of the laser‐based respiratory motion detection system involved spatial accuracy testing, amplitude calibration, and temporal accuracy. Volunteer testing was conducted on eight volunteers at the inferior end of the sternum and the abdomen area. The accuracy of the data recorded by the laser‐based respiratory motion detection system was validated against established clinical reference tracking systems namely real‐time position management (RPM) and Anzai AZ‐733 V system.ResultsCalibration with an Anzai AZ‐773 V and CIRS phantoms demonstrated an average error of 1.17% ± 0.64% and an average amplitude calibration correlation coefficient of 0.975 ± 0.004. Volunteer tests, compared to the Anzai AZ‐733 V clinical system and RPM system, revealed average correlation coefficients for deep inspiration breath‐hold are 0.931 ± 0.02 and 0.936 ± 0.03, respectively, and for free breathing are 0.85 ± 0.07 and 0.77 ± 0.1, respectively.ConclusionsOverall, the data suggest that the in‐house laser‐based respiratory motion detection system performed well, with an error percentage below 10%. A reasonably good correlation coefficient was obtained, indicating that the readings obtained from the laser system are consistent with those set on the phantom and clinical respiratory motion detection systems. Although promising through the calibration process and volunteer tests, further studies are required to generate trigger data linked directly to computerized tomography and linear accelerator facilities, thereby advancing the clinical viability of this innovative laser‐based respiratory motion detection system. 10.1002/acm2.14607 http://creativecommons.org/licenses/by/4.0/
title Calibration and volunteer testing of a prototype contactless respiratory motion detection system based on laser tracking
topic Journal of Applied Clinical Medical Physics
url https://aapm.onlinelibrary.wiley.com/doi/10.1002/acm2.14607