Risk Assessment of Legionella pneumophila in Drinking Water Distribution Systems

Fuente: Wiley Open Access
Salvato in:
Dettagli Bibliografici
Autori principali: Mark W. LeChevallier, Timothy A. Bartrand, Jennifer L. Clancy
Natura: Artículo Open Access
Pubblicazione: Wiley 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1867015154101649408
author Mark W. LeChevallier
Timothy A. Bartrand
Jennifer L. Clancy
author_facet Mark W. LeChevallier
Timothy A. Bartrand
Jennifer L. Clancy
Mark W. LeChevallier
Timothy A. Bartrand
Jennifer L. Clancy
collection Wiley Open Access
contents Risk Assessment of Legionella pneumophila in Drinking Water Distribution Systems Mark W. LeChevallier Timothy A. Bartrand Jennifer L. Clancy AWWA Water Science ABSTRACT An assessment of the public health risk posed by Legionella pneumophila in public drinking water was performed on a dataset of 9181 samples collected by 57 water utilities. Overall, 109 (1.19%) samples were positive for L. pneumophila , and only 5 (0.054%) were greater than 1 MPN/mL. When detected, 73% of the positive results were < 10 MPN/100 mL, indicating that L. pneumophila levels in drinking water distribution systems are typically very low. Applying a Quantitative Microbial Risk Assessment model to the six utilities with the highest frequency of L. pneumophila revealed that the annual risk of infection was below the 10 −4 level used for controlling microbial contaminants under the Safe Drinking Water Act. Overall, a national estimate of risk for exposure to L. pneumophila from drinking water distribution systems would be exceedingly small (< 1 × 10 −7 annual risk of infection). Even the sample with the highest detected concentration of L. pneumophila (267 MPN/100 mL) was less than a 1 × 10 −4 risk of infection for a single exposure (from a faucet). Despite the low risk levels, the results should encourage water utility managers to continue to monitor for L. pneumophila and implement corrective measures so as to maintain levels below public health thresholds. The results of this study should not promote complacency among water utilities but encourage them to apply best management practices for Legionella control. The USEPA should consider including L. pneumophila testing in the next Unregulated Contaminant Monitoring Rule program so that a more complete assessment can be obtained for L. pneumophila in drinking water. 10.1002/aws2.70028 http://onlinelibrary.wiley.com/termsAndConditions#vor
doi_str_mv 10.1002/aws2.70028
format Artículo Open Access
id wiley_oa_10_1002_aws2_70028
institution Wiley Open Access
license_str_mv http://onlinelibrary.wiley.com/termsAndConditions#vor
publishDate 2025
publisher Wiley
record_format wiley_oa
spellingShingle Risk Assessment of Legionella pneumophila in Drinking Water Distribution Systems
Mark W. LeChevallier
Timothy A. Bartrand
Jennifer L. Clancy
AWWA Water Science
Risk Assessment of Legionella pneumophila in Drinking Water Distribution Systems Mark W. LeChevallier Timothy A. Bartrand Jennifer L. Clancy AWWA Water Science ABSTRACT An assessment of the public health risk posed by Legionella pneumophila in public drinking water was performed on a dataset of 9181 samples collected by 57 water utilities. Overall, 109 (1.19%) samples were positive for L. pneumophila , and only 5 (0.054%) were greater than 1 MPN/mL. When detected, 73% of the positive results were < 10 MPN/100 mL, indicating that L. pneumophila levels in drinking water distribution systems are typically very low. Applying a Quantitative Microbial Risk Assessment model to the six utilities with the highest frequency of L. pneumophila revealed that the annual risk of infection was below the 10 −4 level used for controlling microbial contaminants under the Safe Drinking Water Act. Overall, a national estimate of risk for exposure to L. pneumophila from drinking water distribution systems would be exceedingly small (< 1 × 10 −7 annual risk of infection). Even the sample with the highest detected concentration of L. pneumophila (267 MPN/100 mL) was less than a 1 × 10 −4 risk of infection for a single exposure (from a faucet). Despite the low risk levels, the results should encourage water utility managers to continue to monitor for L. pneumophila and implement corrective measures so as to maintain levels below public health thresholds. The results of this study should not promote complacency among water utilities but encourage them to apply best management practices for Legionella control. The USEPA should consider including L. pneumophila testing in the next Unregulated Contaminant Monitoring Rule program so that a more complete assessment can be obtained for L. pneumophila in drinking water. 10.1002/aws2.70028 http://onlinelibrary.wiley.com/termsAndConditions#vor
title Risk Assessment of Legionella pneumophila in Drinking Water Distribution Systems
topic AWWA Water Science
url https://awwa.onlinelibrary.wiley.com/doi/10.1002/aws2.70028