Shedding light on night‐time erections: Determining the feasibility of nocturnal erection detection with penile transdermal light reflection of haemoglobin

Fuente: Wiley Open Access
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Evelien J. Trip, Hille J. Torenvlied, Henk W. Elzevier, Rob C. M. Pelger, Jack J. H. Beck
Format: Artículo Open Access
Veröffentlicht: Wiley 2024
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1867002160873472000
author Evelien J. Trip
Hille J. Torenvlied
Henk W. Elzevier
Rob C. M. Pelger
Jack J. H. Beck
author_facet Evelien J. Trip
Hille J. Torenvlied
Henk W. Elzevier
Rob C. M. Pelger
Jack J. H. Beck
Evelien J. Trip
Hille J. Torenvlied
Henk W. Elzevier
Rob C. M. Pelger
Jack J. H. Beck
collection Wiley Open Access
contents Shedding light on night‐time erections: Determining the feasibility of nocturnal erection detection with penile transdermal light reflection of haemoglobin Evelien J. Trip Hille J. Torenvlied Henk W. Elzevier Rob C. M. Pelger Jack J. H. Beck BJUI Compass Abstract Objectives Utilizing penile saturation and temperature measurements presents a promising avenue for the development of an innovative sensor system aimed at nocturnal erection detection. This study aims to determine the feasibility of erection detection with light reflection of haemoglobin (LRH), as a precursor for penile saturation measurements, as well as penile temperature by comparison with simultaneous overnight RigiScan measurements. Materials and Methods This is a proof‐of‐concept observational study on 10 healthy volunteers with a cross sectional design. A penile transdermal haemoglobin and temperature sensor was developed to measure penile LRH through real‐time monitoring with receiving photodiodes and emitting light‐emitting diode (LED). Besides statistical analysis on LRH, temperature and RigiScan data, a visual assessment was done to determine detectability of changes in the LRH and temperature course during the RigiScan‐annotated erections. Results A total of 40 nocturnal erections from 10 healthy volunteers were annotated with the RigiScan. The LRH values significantly increase during a nocturnal erection ( p  < 0.01) and penile temperature ( p  < 0.01). The largest elevation of temperature was seen in the last erection, with an increase of 0.94°C. The corrected temperature shows an increase of 1.29°C in the last erection. Furthermore, visual detectability was feasible for 80% of the erections with LRH values and 90% with the temperature output. Conclusion Penile LRH and temperature have the potential to serve as an alternative methodology for nocturnal erection detection compared with the currently applied circumference and rigidity measurements. This is an important step in the development of a patient‐friendly and modernized tool for erectile dysfunction diagnostics. An improved sensor should be developed to allow for calculation of saturation percentage from LRH values. In combination with penile temperature measurements, this allows for conduction of further validity studies to work towards translation into clinical practice for non‐invasive ED diagnostics. 10.1002/bco2.410 http://creativecommons.org/licenses/by/4.0/
doi_str_mv 10.1002/bco2.410
format Artículo Open Access
id wiley_oa_10_1002_bco2_410
institution Wiley Open Access
license_str_mv http://creativecommons.org/licenses/by/4.0/
publishDate 2024
publisher Wiley
record_format wiley_oa
spellingShingle Shedding light on night‐time erections: Determining the feasibility of nocturnal erection detection with penile transdermal light reflection of haemoglobin
Evelien J. Trip
Hille J. Torenvlied
Henk W. Elzevier
Rob C. M. Pelger
Jack J. H. Beck
BJUI Compass
Shedding light on night‐time erections: Determining the feasibility of nocturnal erection detection with penile transdermal light reflection of haemoglobin Evelien J. Trip Hille J. Torenvlied Henk W. Elzevier Rob C. M. Pelger Jack J. H. Beck BJUI Compass Abstract Objectives Utilizing penile saturation and temperature measurements presents a promising avenue for the development of an innovative sensor system aimed at nocturnal erection detection. This study aims to determine the feasibility of erection detection with light reflection of haemoglobin (LRH), as a precursor for penile saturation measurements, as well as penile temperature by comparison with simultaneous overnight RigiScan measurements. Materials and Methods This is a proof‐of‐concept observational study on 10 healthy volunteers with a cross sectional design. A penile transdermal haemoglobin and temperature sensor was developed to measure penile LRH through real‐time monitoring with receiving photodiodes and emitting light‐emitting diode (LED). Besides statistical analysis on LRH, temperature and RigiScan data, a visual assessment was done to determine detectability of changes in the LRH and temperature course during the RigiScan‐annotated erections. Results A total of 40 nocturnal erections from 10 healthy volunteers were annotated with the RigiScan. The LRH values significantly increase during a nocturnal erection ( p  < 0.01) and penile temperature ( p  < 0.01). The largest elevation of temperature was seen in the last erection, with an increase of 0.94°C. The corrected temperature shows an increase of 1.29°C in the last erection. Furthermore, visual detectability was feasible for 80% of the erections with LRH values and 90% with the temperature output. Conclusion Penile LRH and temperature have the potential to serve as an alternative methodology for nocturnal erection detection compared with the currently applied circumference and rigidity measurements. This is an important step in the development of a patient‐friendly and modernized tool for erectile dysfunction diagnostics. An improved sensor should be developed to allow for calculation of saturation percentage from LRH values. In combination with penile temperature measurements, this allows for conduction of further validity studies to work towards translation into clinical practice for non‐invasive ED diagnostics. 10.1002/bco2.410 http://creativecommons.org/licenses/by/4.0/
title Shedding light on night‐time erections: Determining the feasibility of nocturnal erection detection with penile transdermal light reflection of haemoglobin
topic BJUI Compass
url https://bjui-journals.onlinelibrary.wiley.com/doi/10.1002/bco2.410