The Influence of Design Parameters on the Operational Energy Carbon Emissions of a Commercial Building in Pakistan

Fuente: Wiley Open Access
Saved in:
Bibliographic Details
Main Authors: Fakhre Alam Khan, Muhammad Aashan, Muhammad Azhar, Farooq Ahmad, Muhammad Saad, Zahid Ullah
Format: Artículo Open Access
Published: Wiley 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867007183979282432
author Fakhre Alam Khan
Muhammad Aashan
Muhammad Azhar
Farooq Ahmad
Muhammad Saad
Zahid Ullah
author_facet Fakhre Alam Khan
Muhammad Aashan
Muhammad Azhar
Farooq Ahmad
Muhammad Saad
Zahid Ullah
Fakhre Alam Khan
Muhammad Aashan
Muhammad Azhar
Farooq Ahmad
Muhammad Saad
Zahid Ullah
collection Wiley Open Access
contents The Influence of Design Parameters on the Operational Energy Carbon Emissions of a Commercial Building in Pakistan Fakhre Alam Khan Muhammad Aashan Muhammad Azhar Farooq Ahmad Muhammad Saad Zahid Ullah Engineering Reports ABSTRACTBuildings are responsible for 37% of CO2 emissions and 36% of energy use worldwide, making them significant contributors to both energy use and carbon emissions, due to which building energy efficiency is currently a top priority for regional, national, and global energy policy. This study evaluates building design features, such as window wall ratio (WWR), orientation, and shading coefficient (SC) for its single‐, low‐E double‐, and low‐E triple‐glazed windows. The building analyzed in this study is a hypothetical commercial building located in Lahore, Pakistan (ASHRAE zone 1B). The results show that compared to unglazed windows with a SC of 0.2 and 0.3, peak cooling total load (PCTL) and CO2 emissions are reduced by 17.84% and 17%, respectively, for single‐glazed windows. Similarly, low‐E double‐glazed windows reduce 21.3% and 20.9% in PCTL and CO2 emissions, while low‐E triple‐glazed windows result in reductions of 21.8% and 21.1%, respectively. Reducing the WWR from 15.14% to 4.94% results in a 5.35% reduction in PCTL and CO2 emissions. Moreover, Using the optimized orientation of the building (180° clockwise from north) further decreases PCTL and CO2 emissions by 8.63%. This analysis concludes that significant energy and environmental gains can be achieved by higher‐quality windows, utilizing optimized orientation, and reducing the WWR. In addition to ensuring long‐term cost savings, this strategic approach promotes a more sustainable and environmentally friendly future for future generations. 10.1002/eng2.70013 http://creativecommons.org/licenses/by/4.0/
doi_str_mv 10.1002/eng2.70013
format Artículo Open Access
id wiley_oa_10_1002_eng2_70013
institution Wiley Open Access
license_str_mv http://creativecommons.org/licenses/by/4.0/
publishDate 2025
publisher Wiley
record_format wiley_oa
spellingShingle The Influence of Design Parameters on the Operational Energy Carbon Emissions of a Commercial Building in Pakistan
Fakhre Alam Khan
Muhammad Aashan
Muhammad Azhar
Farooq Ahmad
Muhammad Saad
Zahid Ullah
Engineering Reports
The Influence of Design Parameters on the Operational Energy Carbon Emissions of a Commercial Building in Pakistan Fakhre Alam Khan Muhammad Aashan Muhammad Azhar Farooq Ahmad Muhammad Saad Zahid Ullah Engineering Reports ABSTRACTBuildings are responsible for 37% of CO2 emissions and 36% of energy use worldwide, making them significant contributors to both energy use and carbon emissions, due to which building energy efficiency is currently a top priority for regional, national, and global energy policy. This study evaluates building design features, such as window wall ratio (WWR), orientation, and shading coefficient (SC) for its single‐, low‐E double‐, and low‐E triple‐glazed windows. The building analyzed in this study is a hypothetical commercial building located in Lahore, Pakistan (ASHRAE zone 1B). The results show that compared to unglazed windows with a SC of 0.2 and 0.3, peak cooling total load (PCTL) and CO2 emissions are reduced by 17.84% and 17%, respectively, for single‐glazed windows. Similarly, low‐E double‐glazed windows reduce 21.3% and 20.9% in PCTL and CO2 emissions, while low‐E triple‐glazed windows result in reductions of 21.8% and 21.1%, respectively. Reducing the WWR from 15.14% to 4.94% results in a 5.35% reduction in PCTL and CO2 emissions. Moreover, Using the optimized orientation of the building (180° clockwise from north) further decreases PCTL and CO2 emissions by 8.63%. This analysis concludes that significant energy and environmental gains can be achieved by higher‐quality windows, utilizing optimized orientation, and reducing the WWR. In addition to ensuring long‐term cost savings, this strategic approach promotes a more sustainable and environmentally friendly future for future generations. 10.1002/eng2.70013 http://creativecommons.org/licenses/by/4.0/
title The Influence of Design Parameters on the Operational Energy Carbon Emissions of a Commercial Building in Pakistan
topic Engineering Reports
url https://onlinelibrary.wiley.com/doi/10.1002/eng2.70013