Plastic Hinge Length of RC Shear Walls: A Mechanical Approach Considering Plane Bending and Tension Shift

Fuente: Wiley Open Access
Salvato in:
Dettagli Bibliografici
Autori principali: Harald Schuler, Arthur Pröbsting
Natura: Artículo Open Access
Pubblicazione: Wiley 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1867019154620416001
author Harald Schuler
Arthur Pröbsting
author_facet Harald Schuler
Arthur Pröbsting
Harald Schuler
Arthur Pröbsting
collection Wiley Open Access
contents Plastic Hinge Length of RC Shear Walls: A Mechanical Approach Considering Plane Bending and Tension Shift Harald Schuler Arthur Pröbsting Earthquake Engineering & Structural Dynamics ABSTRACTShear walls are often used to stabilize buildings or bridges against horizontal loads like wind or earthquakes. In earthquake design, ductile behavior is usually targeted so that the energy from earthquake excitation can be dissipated. An approach employing a plastic hinge on the wall base is widely used. The length of the plastic hinge is decisive for the rotational capacity, and thus for the ductility of a wall. Due to the complicated behavior of reinforced concrete under cyclic loading, one finds almost only empirical approaches in literature and design regulations to determine the plastic hinge length. The plastic hinge length is influenced by the moment gradient and the shift of tensile forces along the tensile chord. This phenomenon, known as the “tension shift,” is due to the interaction between bending and shear, resulting in inclined cracking. This article separates the tension shift and plane section bending contributions to the plastic hinge length, which are not clearly separated or sufficiently accounted for in empirical approaches. The aim is to allow calculation of displacements resulting from the tension shift in addition to known flexural displacements derived from the moment–curvature relationship under the assumption of plane section bending. Therefore, the tension shift length was measured on several existing shear wall experiments and in a parametric study performed with a nonlinear finite element analysis. Finally, a design approach is proposed with an estimation of the shift angle, which is used to calculate the part of the plastic hinge length due to tension shift. The approach is applicable to both existing walls with small reinforcement amounts and new ductile earthquake walls. 10.1002/eqe.4375 http://creativecommons.org/licenses/by/4.0/
doi_str_mv 10.1002/eqe.4375
format Artículo Open Access
id wiley_oa_10_1002_eqe_4375
institution Wiley Open Access
license_str_mv http://creativecommons.org/licenses/by/4.0/
publishDate 2025
publisher Wiley
record_format wiley_oa
spellingShingle Plastic Hinge Length of RC Shear Walls: A Mechanical Approach Considering Plane Bending and Tension Shift
Harald Schuler
Arthur Pröbsting
Earthquake Engineering & Structural Dynamics
Plastic Hinge Length of RC Shear Walls: A Mechanical Approach Considering Plane Bending and Tension Shift Harald Schuler Arthur Pröbsting Earthquake Engineering & Structural Dynamics ABSTRACTShear walls are often used to stabilize buildings or bridges against horizontal loads like wind or earthquakes. In earthquake design, ductile behavior is usually targeted so that the energy from earthquake excitation can be dissipated. An approach employing a plastic hinge on the wall base is widely used. The length of the plastic hinge is decisive for the rotational capacity, and thus for the ductility of a wall. Due to the complicated behavior of reinforced concrete under cyclic loading, one finds almost only empirical approaches in literature and design regulations to determine the plastic hinge length. The plastic hinge length is influenced by the moment gradient and the shift of tensile forces along the tensile chord. This phenomenon, known as the “tension shift,” is due to the interaction between bending and shear, resulting in inclined cracking. This article separates the tension shift and plane section bending contributions to the plastic hinge length, which are not clearly separated or sufficiently accounted for in empirical approaches. The aim is to allow calculation of displacements resulting from the tension shift in addition to known flexural displacements derived from the moment–curvature relationship under the assumption of plane section bending. Therefore, the tension shift length was measured on several existing shear wall experiments and in a parametric study performed with a nonlinear finite element analysis. Finally, a design approach is proposed with an estimation of the shift angle, which is used to calculate the part of the plastic hinge length due to tension shift. The approach is applicable to both existing walls with small reinforcement amounts and new ductile earthquake walls. 10.1002/eqe.4375 http://creativecommons.org/licenses/by/4.0/
title Plastic Hinge Length of RC Shear Walls: A Mechanical Approach Considering Plane Bending and Tension Shift
topic Earthquake Engineering & Structural Dynamics
url https://onlinelibrary.wiley.com/doi/10.1002/eqe.4375