Candidate reference measurement procedure for serum 17‐hydroxyprogesterone quantification via isotope dilution liquid chromatography–tandem mass spectrometry

Fuente: Wiley Open Access
Saved in:
Bibliographic Details
Main Authors: Ji Zhang, Yang Jiang, Ting Liu, Xiongwei Liu, Hui Huang, Yanxiang Cheng, Jieyan Li, Bangning Cheng, Chungen Qian, Xufu Xiang, Jun‐Fa Xu
Format: Artículo Open Access
Published: Wiley 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867016604977463296
author Ji Zhang
Yang Jiang
Ting Liu
Xiongwei Liu
Hui Huang
Yanxiang Cheng
Jieyan Li
Bangning Cheng
Chungen Qian
Xufu Xiang
Jun‐Fa Xu
author_facet Ji Zhang
Yang Jiang
Ting Liu
Xiongwei Liu
Hui Huang
Yanxiang Cheng
Jieyan Li
Bangning Cheng
Chungen Qian
Xufu Xiang
Jun‐Fa Xu
Ji Zhang
Yang Jiang
Ting Liu
Xiongwei Liu
Hui Huang
Yanxiang Cheng
Jieyan Li
Bangning Cheng
Chungen Qian
Xufu Xiang
Jun‐Fa Xu
collection Wiley Open Access
contents Candidate reference measurement procedure for serum 17‐hydroxyprogesterone quantification via isotope dilution liquid chromatography–tandem mass spectrometry Ji Zhang Yang Jiang Ting Liu Xiongwei Liu Hui Huang Yanxiang Cheng Jieyan Li Bangning Cheng Chungen Qian Xufu Xiang Jun‐Fa Xu iLABMED AbstractBackgroundAccurate quantification of 17‐hydroxyprogesterone (17‐OHP) in serum is vital for clinical and research applications. However, inter‐laboratory variability in test results exists owing to the lack of a standardized reference measurement procedure (RMP). Therefore, in this study, we developed a highly accurate, cost‐effective, and user‐friendly candidate RMP (cRMP) for analyzing 17‐OHP in serum.MethodsWe quantified 17‐OHP in serum using a one‐step liquid–liquid extraction method with the addition of 17‐OHP‐13C3, followed by liquid chromatography–tandem mass spectrometry. The ability of these methods to suppress interference was evaluated by chromatographic analysis. We assessed accuracy, specificity, the lower limit of quantitation, linearity, and matrix effects by following the standards specified by the Clinical and Laboratory Standards Institute. The consistency between the developed cRMP and the chemiluminescence method was evaluated through experiments with 120 clinical samples.ResultsThe developed cRMP required only 8 min for accurate quantification of serum 17‐OHP without bias from matrix effects or interference from 19 metabolites added as potential interferents. The method exhibited favorable measurement performance, with a quantitation limit of 0.086 ng/mL, linear range of 0.1–400 ng/mL, a total imprecision of ≤2.90%, spike recovery of 100.1%–100.6%, and relative deviations from assigned target values (RfB Institution) of −2.91% to 1.10%. The cRMP demonstrated good consistency with the conventional assay (chemiluminescence method), with a correlation coefficient R of 0.96977.ConclusionA cRMP with high accuracy, cost‐effectiveness, and convenient operation was developed for quantifying 17‐OHP in serum. Its simplicity and robust performance make it an invaluable addition to the arsenal of analytical tools available for laboratories. This method can enhance the accuracy and reliability of 17‐OHP measurements across various laboratories. 10.1002/ila2.39 http://creativecommons.org/licenses/by/4.0/
doi_str_mv 10.1002/ila2.39
format Artículo Open Access
id wiley_oa_10_1002_ila2_39
institution Wiley Open Access
license_str_mv http://creativecommons.org/licenses/by/4.0/
publishDate 2024
publisher Wiley
record_format wiley_oa
spellingShingle Candidate reference measurement procedure for serum 17‐hydroxyprogesterone quantification via isotope dilution liquid chromatography–tandem mass spectrometry
Ji Zhang
Yang Jiang
Ting Liu
Xiongwei Liu
Hui Huang
Yanxiang Cheng
Jieyan Li
Bangning Cheng
Chungen Qian
Xufu Xiang
Jun‐Fa Xu
iLABMED
Candidate reference measurement procedure for serum 17‐hydroxyprogesterone quantification via isotope dilution liquid chromatography–tandem mass spectrometry Ji Zhang Yang Jiang Ting Liu Xiongwei Liu Hui Huang Yanxiang Cheng Jieyan Li Bangning Cheng Chungen Qian Xufu Xiang Jun‐Fa Xu iLABMED AbstractBackgroundAccurate quantification of 17‐hydroxyprogesterone (17‐OHP) in serum is vital for clinical and research applications. However, inter‐laboratory variability in test results exists owing to the lack of a standardized reference measurement procedure (RMP). Therefore, in this study, we developed a highly accurate, cost‐effective, and user‐friendly candidate RMP (cRMP) for analyzing 17‐OHP in serum.MethodsWe quantified 17‐OHP in serum using a one‐step liquid–liquid extraction method with the addition of 17‐OHP‐13C3, followed by liquid chromatography–tandem mass spectrometry. The ability of these methods to suppress interference was evaluated by chromatographic analysis. We assessed accuracy, specificity, the lower limit of quantitation, linearity, and matrix effects by following the standards specified by the Clinical and Laboratory Standards Institute. The consistency between the developed cRMP and the chemiluminescence method was evaluated through experiments with 120 clinical samples.ResultsThe developed cRMP required only 8 min for accurate quantification of serum 17‐OHP without bias from matrix effects or interference from 19 metabolites added as potential interferents. The method exhibited favorable measurement performance, with a quantitation limit of 0.086 ng/mL, linear range of 0.1–400 ng/mL, a total imprecision of ≤2.90%, spike recovery of 100.1%–100.6%, and relative deviations from assigned target values (RfB Institution) of −2.91% to 1.10%. The cRMP demonstrated good consistency with the conventional assay (chemiluminescence method), with a correlation coefficient R of 0.96977.ConclusionA cRMP with high accuracy, cost‐effectiveness, and convenient operation was developed for quantifying 17‐OHP in serum. Its simplicity and robust performance make it an invaluable addition to the arsenal of analytical tools available for laboratories. This method can enhance the accuracy and reliability of 17‐OHP measurements across various laboratories. 10.1002/ila2.39 http://creativecommons.org/licenses/by/4.0/
title Candidate reference measurement procedure for serum 17‐hydroxyprogesterone quantification via isotope dilution liquid chromatography–tandem mass spectrometry
topic iLABMED
url https://onlinelibrary.wiley.com/doi/10.1002/ila2.39