Implementation of Ultrasound‐Guided Cannulation Training Across Eight NHSBT Therapeutic Apheresis Units in England

Fuente: Wiley Open Access
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Daniel Putensen, Samuel Ntakirutimana, Marc Lyon, Bridget Audsley, Nicola Newbound
Format: Artículo Open Access
Publié: Wiley 2024
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1867018950769901568
author Daniel Putensen
Samuel Ntakirutimana
Marc Lyon
Bridget Audsley
Nicola Newbound
author_facet Daniel Putensen
Samuel Ntakirutimana
Marc Lyon
Bridget Audsley
Nicola Newbound
Daniel Putensen
Samuel Ntakirutimana
Marc Lyon
Bridget Audsley
Nicola Newbound
collection Wiley Open Access
contents Implementation of Ultrasound‐Guided Cannulation Training Across Eight NHSBT Therapeutic Apheresis Units in England Daniel Putensen Samuel Ntakirutimana Marc Lyon Bridget Audsley Nicola Newbound Journal of Clinical Apheresis ABSTRACTUltrasound‐guided cannulation (USGC) of a peripheral vein reduces the need for central vascular access device (CVAD) placement to perform a successful apheresis procedure. Effective training of healthcare professionals to acquire this skill is essential. Here, we report on the implementation of the USGC training across eight apheresis units in England. A 3‐h introductory training program was devised with theoretical and practical elements. This was followed by supervised USGC practices on any patient ≥ 18 years old, regardless of venous status. Data on all supervised USGC attempts were recorded and analyzed. Over an 11‐month period, 11 nurses were trained to USGC competency with another six nurses still in training, resulting in seven out of eight units having at least one USGC‐competent nurse. In one unit, USGC training has not started yet. Three hundred sixty‐one supervised USGC episodes on 168 patients and donors took place; of these, 178 were done for training purposes only on patients who had visible and palpable veins, 179 USGC were done on patients with difficult venous status and four were not recorded. The period from first supervised USGC to competency was a median of 45 days (Range: 17–166 days), with a median of 15 successful (Range: 10–30) and two unsuccessful (Range: 1–15) USGC being performed per trainee. The placement of 57 CVADs and 41 multiple cannulation attempts have been avoided. USGC is a useful tool to reduce the need for CVAD. Training across multiple apheresis units is a lengthy procedure, but it can be successfully implemented. 10.1002/jca.22149 http://onlinelibrary.wiley.com/termsAndConditions#vor
doi_str_mv 10.1002/jca.22149
format Artículo Open Access
id wiley_oa_10_1002_jca_22149
institution Wiley Open Access
license_str_mv http://onlinelibrary.wiley.com/termsAndConditions#vor
publishDate 2024
publisher Wiley
record_format wiley_oa
spellingShingle Implementation of Ultrasound‐Guided Cannulation Training Across Eight NHSBT Therapeutic Apheresis Units in England
Daniel Putensen
Samuel Ntakirutimana
Marc Lyon
Bridget Audsley
Nicola Newbound
Journal of Clinical Apheresis
Implementation of Ultrasound‐Guided Cannulation Training Across Eight NHSBT Therapeutic Apheresis Units in England Daniel Putensen Samuel Ntakirutimana Marc Lyon Bridget Audsley Nicola Newbound Journal of Clinical Apheresis ABSTRACTUltrasound‐guided cannulation (USGC) of a peripheral vein reduces the need for central vascular access device (CVAD) placement to perform a successful apheresis procedure. Effective training of healthcare professionals to acquire this skill is essential. Here, we report on the implementation of the USGC training across eight apheresis units in England. A 3‐h introductory training program was devised with theoretical and practical elements. This was followed by supervised USGC practices on any patient ≥ 18 years old, regardless of venous status. Data on all supervised USGC attempts were recorded and analyzed. Over an 11‐month period, 11 nurses were trained to USGC competency with another six nurses still in training, resulting in seven out of eight units having at least one USGC‐competent nurse. In one unit, USGC training has not started yet. Three hundred sixty‐one supervised USGC episodes on 168 patients and donors took place; of these, 178 were done for training purposes only on patients who had visible and palpable veins, 179 USGC were done on patients with difficult venous status and four were not recorded. The period from first supervised USGC to competency was a median of 45 days (Range: 17–166 days), with a median of 15 successful (Range: 10–30) and two unsuccessful (Range: 1–15) USGC being performed per trainee. The placement of 57 CVADs and 41 multiple cannulation attempts have been avoided. USGC is a useful tool to reduce the need for CVAD. Training across multiple apheresis units is a lengthy procedure, but it can be successfully implemented. 10.1002/jca.22149 http://onlinelibrary.wiley.com/termsAndConditions#vor
title Implementation of Ultrasound‐Guided Cannulation Training Across Eight NHSBT Therapeutic Apheresis Units in England
topic Journal of Clinical Apheresis
url https://onlinelibrary.wiley.com/doi/10.1002/jca.22149