Long‐Term Management of Recurrent Antibody‐Induced Bile Salt Export Pump Deficiency After Liver Transplantation Using Therapeutic Plasma Exchange

Fuente: Wiley Open Access
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: David Daniel, Diana Fang, Kiyoko Oshima, Sonja O. Vozniak, Aaron A. R. Tobian, Elizabeth P. Crowe, James Peter Hamilton, Evan M. Bloch, Herleen Rai
Format: Artículo Open Access
Veröffentlicht: Wiley 2026
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1867011082482089984
author David Daniel
Diana Fang
Kiyoko Oshima
Sonja O. Vozniak
Aaron A. R. Tobian
Elizabeth P. Crowe
James Peter Hamilton
Evan M. Bloch
Herleen Rai
author_facet David Daniel
Diana Fang
Kiyoko Oshima
Sonja O. Vozniak
Aaron A. R. Tobian
Elizabeth P. Crowe
James Peter Hamilton
Evan M. Bloch
Herleen Rai
David Daniel
Diana Fang
Kiyoko Oshima
Sonja O. Vozniak
Aaron A. R. Tobian
Elizabeth P. Crowe
James Peter Hamilton
Evan M. Bloch
Herleen Rai
collection Wiley Open Access
contents Long‐Term Management of Recurrent Antibody‐Induced Bile Salt Export Pump Deficiency After Liver Transplantation Using Therapeutic Plasma Exchange David Daniel Diana Fang Kiyoko Oshima Sonja O. Vozniak Aaron A. R. Tobian Elizabeth P. Crowe James Peter Hamilton Evan M. Bloch Herleen Rai Journal of Clinical Apheresis ABSTRACT Progressive Familial Intrahepatic Cholestasis type 2 (PFIC‐2) is a rare autosomal recessive liver disorder caused by ABCB11 mutations impairing the bile salt export pump (BSEP). Liver transplantation is typically considered curative; however, a subset of patients develop antibody‐induced BSEP deficiency (AIBD), a rare post‐transplant complication driven by recipient IgG antibodies against graft BSEP. Patients often present with recurrent cholestasis and graft dysfunction. Therapeutic plasma exchange (TPE) is increasingly used to remove circulating antibodies, often alongside immunomodulatory therapies. We describe a patient with PFIC‐2 who developed four distinct AIBD relapses over a 24‐year period, beginning 12 years after transplantation. Each relapse was treated with a coordinated regimen including TPE, intravenous immunoglobulin (IVIg), rituximab, and optimized maintenance immunosuppression. TPE procedures were performed using the Spectra Optia system with one plasma volume exchange using citrate anticoagulation. Across all relapses, TPE was associated with rapid reductions in cholestatic markers, with the greatest improvements noted after apheresis initiation. TPE procedure intensity evolved over time, with earlier initiation and a gradual increase in the total number of exchanges per relapse. Biopsies demonstrated progressive cholestatic injury, yet graft function remained preserved and re‐transplantation was avoided. Adverse events were infrequent and managed conservatively. This case highlights the potential role of early and sustained use of TPE as part of a multimodal strategy for managing recurrent AIBD. Consistent clinical and biochemical improvement across relapses supports incorporating TPE with immunosuppression and B‐cell targeted therapy in similar presentations. Further studies are needed to clarify optimal timing, frequency, and treatment combinations. 10.1002/jca.70096 http://onlinelibrary.wiley.com/termsAndConditions#vor
doi_str_mv 10.1002/jca.70096
format Artículo Open Access
id wiley_oa_10_1002_jca_70096
institution Wiley Open Access
license_str_mv http://onlinelibrary.wiley.com/termsAndConditions#vor
publishDate 2026
publisher Wiley
record_format wiley_oa
spellingShingle Long‐Term Management of Recurrent Antibody‐Induced Bile Salt Export Pump Deficiency After Liver Transplantation Using Therapeutic Plasma Exchange
David Daniel
Diana Fang
Kiyoko Oshima
Sonja O. Vozniak
Aaron A. R. Tobian
Elizabeth P. Crowe
James Peter Hamilton
Evan M. Bloch
Herleen Rai
Journal of Clinical Apheresis
Long‐Term Management of Recurrent Antibody‐Induced Bile Salt Export Pump Deficiency After Liver Transplantation Using Therapeutic Plasma Exchange David Daniel Diana Fang Kiyoko Oshima Sonja O. Vozniak Aaron A. R. Tobian Elizabeth P. Crowe James Peter Hamilton Evan M. Bloch Herleen Rai Journal of Clinical Apheresis ABSTRACT Progressive Familial Intrahepatic Cholestasis type 2 (PFIC‐2) is a rare autosomal recessive liver disorder caused by ABCB11 mutations impairing the bile salt export pump (BSEP). Liver transplantation is typically considered curative; however, a subset of patients develop antibody‐induced BSEP deficiency (AIBD), a rare post‐transplant complication driven by recipient IgG antibodies against graft BSEP. Patients often present with recurrent cholestasis and graft dysfunction. Therapeutic plasma exchange (TPE) is increasingly used to remove circulating antibodies, often alongside immunomodulatory therapies. We describe a patient with PFIC‐2 who developed four distinct AIBD relapses over a 24‐year period, beginning 12 years after transplantation. Each relapse was treated with a coordinated regimen including TPE, intravenous immunoglobulin (IVIg), rituximab, and optimized maintenance immunosuppression. TPE procedures were performed using the Spectra Optia system with one plasma volume exchange using citrate anticoagulation. Across all relapses, TPE was associated with rapid reductions in cholestatic markers, with the greatest improvements noted after apheresis initiation. TPE procedure intensity evolved over time, with earlier initiation and a gradual increase in the total number of exchanges per relapse. Biopsies demonstrated progressive cholestatic injury, yet graft function remained preserved and re‐transplantation was avoided. Adverse events were infrequent and managed conservatively. This case highlights the potential role of early and sustained use of TPE as part of a multimodal strategy for managing recurrent AIBD. Consistent clinical and biochemical improvement across relapses supports incorporating TPE with immunosuppression and B‐cell targeted therapy in similar presentations. Further studies are needed to clarify optimal timing, frequency, and treatment combinations. 10.1002/jca.70096 http://onlinelibrary.wiley.com/termsAndConditions#vor
title Long‐Term Management of Recurrent Antibody‐Induced Bile Salt Export Pump Deficiency After Liver Transplantation Using Therapeutic Plasma Exchange
topic Journal of Clinical Apheresis
url https://onlinelibrary.wiley.com/doi/10.1002/jca.70096