Streamlined pin‐ridge‐filter design for single‐energy proton FLASH planning

Fuente: Wiley Open Access
Salvato in:
Dettagli Bibliografici
Autori principali: Chaoqiong Ma, Jun Zhou, Chih‐Wei Chang, Yinan Wang, Pretesh R. Patel, David S. Yu, Sibo Tian, Xiaofeng Yang
Natura: Artículo Open Access
Pubblicazione: Wiley 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1867007235624796160
author Chaoqiong Ma
Jun Zhou
Chih‐Wei Chang
Yinan Wang
Pretesh R. Patel
David S. Yu
Sibo Tian
Xiaofeng Yang
author_facet Chaoqiong Ma
Jun Zhou
Chih‐Wei Chang
Yinan Wang
Pretesh R. Patel
David S. Yu
Sibo Tian
Xiaofeng Yang
Chaoqiong Ma
Jun Zhou
Chih‐Wei Chang
Yinan Wang
Pretesh R. Patel
David S. Yu
Sibo Tian
Xiaofeng Yang
collection Wiley Open Access
contents Streamlined pin‐ridge‐filter design for single‐energy proton FLASH planning Chaoqiong Ma Jun Zhou Chih‐Wei Chang Yinan Wang Pretesh R. Patel David S. Yu Sibo Tian Xiaofeng Yang Medical Physics AbstractBackgroundFLASH radiotherapy (FLASH‐RT) with ultra‐high dose rate has yielded promising results in reducing normal tissue toxicity while maintaining tumor control. Planning with single‐energy proton beams modulated by ridge filters (RFs) has been demonstrated feasible for FLASH‐RT.PurposeThis study explored the feasibility of a streamlined pin‐shaped RF (pin‐RF) design, characterized by coarse resolution and sparsely distributed ridge pins, for single‐energy proton FLASH planning.MethodsAn inverse planning framework integrated within a treatment planning system was established to design streamlined pin RFs for single‐energy FLASH planning. The framework involves generating a multi‐energy proton beam plan using intensity‐modulated proton therapy (IMPT) planning based on downstream energy modulation strategy (IMPT‐DS), followed by a nested pencil‐beam‐direction‐based (PBD‐based) spot reduction process to iteratively reduce the total number of PBDs and energy layers along each PBD for the IMPT‐DS plan. The IMPT‐DS plan is then translated into the pin‐RFs and the single‐energy beam configurations for IMPT planning with pin‐RFs (IMPT‐RF). This framework was validated on three lung cases, quantifying the FLASH dose of the IMPT‐RF plan using the FLASH effectiveness model. The FLASH dose was then compared to the reference dose of a conventional IMPT plan to measure the clinical benefit of the FLASH planning technique.ResultsThe IMPT‐RF plans closely matched the corresponding IMPT‐DS plans in high dose conformity (conformity index of <1.2), with minimal changes in V7Gy and V7.4 Gy for the lung (<3%) and small increases in maximum doses (Dmax) for other normal structures (<3.4 Gy). Comparing the FLASH doses to the doses of corresponding IMPT‐RF plans, drastic reductions of up to nearly 33% were observed in Dmax for the normal structures situated in the high‐to‐moderate‐dose regions, while negligible changes were found in Dmax for normal structures in low‐dose regions. Positive clinical benefits were seen in comparing the FLASH doses to the reference doses, with notable reductions of 21.4%–33.0% in Dmax for healthy tissues in the high‐dose regions. However, in the moderate‐to‐low‐dose regions, only marginal positive or even negative clinical benefit for normal tissues were observed, such as increased lung V7Gy and V7.4 Gy (up to 17.6%).ConclusionsA streamlined pin‐RF design was developed and its effectiveness for single‐energy proton FLASH planning was validated, revealing positive clinical benefits for the normal tissues in the high dose regions. The coarsened design of the pin‐RF demonstrates potential advantages, including cost efficiency and ease of adjustability, making it a promising option for efficient production. 10.1002/mp.16939 http://onlinelibrary.wiley.com/termsAndConditions#vor
doi_str_mv 10.1002/mp.16939
format Artículo Open Access
id wiley_oa_10_1002_mp_16939
institution Wiley Open Access
license_str_mv http://onlinelibrary.wiley.com/termsAndConditions#vor
publishDate 2024
publisher Wiley
record_format wiley_oa
spellingShingle Streamlined pin‐ridge‐filter design for single‐energy proton FLASH planning
Chaoqiong Ma
Jun Zhou
Chih‐Wei Chang
Yinan Wang
Pretesh R. Patel
David S. Yu
Sibo Tian
Xiaofeng Yang
Medical Physics
Streamlined pin‐ridge‐filter design for single‐energy proton FLASH planning Chaoqiong Ma Jun Zhou Chih‐Wei Chang Yinan Wang Pretesh R. Patel David S. Yu Sibo Tian Xiaofeng Yang Medical Physics AbstractBackgroundFLASH radiotherapy (FLASH‐RT) with ultra‐high dose rate has yielded promising results in reducing normal tissue toxicity while maintaining tumor control. Planning with single‐energy proton beams modulated by ridge filters (RFs) has been demonstrated feasible for FLASH‐RT.PurposeThis study explored the feasibility of a streamlined pin‐shaped RF (pin‐RF) design, characterized by coarse resolution and sparsely distributed ridge pins, for single‐energy proton FLASH planning.MethodsAn inverse planning framework integrated within a treatment planning system was established to design streamlined pin RFs for single‐energy FLASH planning. The framework involves generating a multi‐energy proton beam plan using intensity‐modulated proton therapy (IMPT) planning based on downstream energy modulation strategy (IMPT‐DS), followed by a nested pencil‐beam‐direction‐based (PBD‐based) spot reduction process to iteratively reduce the total number of PBDs and energy layers along each PBD for the IMPT‐DS plan. The IMPT‐DS plan is then translated into the pin‐RFs and the single‐energy beam configurations for IMPT planning with pin‐RFs (IMPT‐RF). This framework was validated on three lung cases, quantifying the FLASH dose of the IMPT‐RF plan using the FLASH effectiveness model. The FLASH dose was then compared to the reference dose of a conventional IMPT plan to measure the clinical benefit of the FLASH planning technique.ResultsThe IMPT‐RF plans closely matched the corresponding IMPT‐DS plans in high dose conformity (conformity index of <1.2), with minimal changes in V7Gy and V7.4 Gy for the lung (<3%) and small increases in maximum doses (Dmax) for other normal structures (<3.4 Gy). Comparing the FLASH doses to the doses of corresponding IMPT‐RF plans, drastic reductions of up to nearly 33% were observed in Dmax for the normal structures situated in the high‐to‐moderate‐dose regions, while negligible changes were found in Dmax for normal structures in low‐dose regions. Positive clinical benefits were seen in comparing the FLASH doses to the reference doses, with notable reductions of 21.4%–33.0% in Dmax for healthy tissues in the high‐dose regions. However, in the moderate‐to‐low‐dose regions, only marginal positive or even negative clinical benefit for normal tissues were observed, such as increased lung V7Gy and V7.4 Gy (up to 17.6%).ConclusionsA streamlined pin‐RF design was developed and its effectiveness for single‐energy proton FLASH planning was validated, revealing positive clinical benefits for the normal tissues in the high dose regions. The coarsened design of the pin‐RF demonstrates potential advantages, including cost efficiency and ease of adjustability, making it a promising option for efficient production. 10.1002/mp.16939 http://onlinelibrary.wiley.com/termsAndConditions#vor
title Streamlined pin‐ridge‐filter design for single‐energy proton FLASH planning
topic Medical Physics
url https://aapm.onlinelibrary.wiley.com/doi/10.1002/mp.16939